These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
120 related articles for article (PubMed ID: 38524735)
41. High-resolution time-of-flight PET detector with 100 ps coincidence time resolution using a side-coupled phoswich configuration. Lee MS; Cates JW; Gonzalez-Montoro A; Levin CS Phys Med Biol; 2021 Jun; 66(12):. PubMed ID: 34106089 [TBL] [Abstract][Full Text] [Related]
42. Improved image quality using monolithic scintillator detectors with dual-sided readout in a whole-body TOF-PET ring: a simulation study. Tabacchini V; Surti S; Borghi G; Karp JS; Schaart DR Phys Med Biol; 2017 Feb; 62(5):2018-2032. PubMed ID: 28192287 [TBL] [Abstract][Full Text] [Related]
43. Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction. Maas MC; Schaart DR; van der Laan DJ; Bruyndonckx P; Lemaître C; Beekman FJ; van Eijk CW Phys Med Biol; 2009 Apr; 54(7):1893-908. PubMed ID: 19265203 [TBL] [Abstract][Full Text] [Related]
44. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography. Habte F; Foudray AM; Olcott PD; Levin CS Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575 [TBL] [Abstract][Full Text] [Related]
45. Simulation study of a brain PET scanner using TOF-DOI detectors equipped with first interaction position detection. Li Y; Watanabe M; Isobe T; Ote K; Tokui A; Omura T; Liu H Phys Med Biol; 2022 Dec; 68(1):. PubMed ID: 36560889 [No Abstract] [Full Text] [Related]
46. A Prototype Detector for a Novel High-Resolution PET System: BazookaPET. Park R; Miller BW; Jha AK; Furenlid LR; Hunter WC; Barrett HH IEEE Nucl Sci Symp Conf Rec (1997); 2012; 2012():2123-2127. PubMed ID: 26316682 [TBL] [Abstract][Full Text] [Related]
47. Evaluation of monolithic crystal detector with dual-ended readout utilizing multiplexing method. Zeng X; Zhang Z; Li D; Huang X; Wang Z; Wang Y; Zhou W; Wang P; Zhu M; Wei Q; Gong H; Wei L Phys Med Biol; 2024 Apr; 69(8):. PubMed ID: 38484392 [No Abstract] [Full Text] [Related]
48. A DOI Detector With Crystal Scatter Identification Capability for High Sensitivity and High Spatial Resolution PET Imaging. Gu Z; Prout DL; Silverman RW; Herman H; Dooraghi A; Chatziioannou AF IEEE Trans Nucl Sci; 2015 Jun; 62(3):740-747. PubMed ID: 26478600 [TBL] [Abstract][Full Text] [Related]
49. Walk-through flat panel total-body PET: a patient-centered design for high throughput imaging at lower cost using DOI-capable high-resolution monolithic detectors. Vandenberghe S; Muller FM; Withofs N; Dadgar M; Maebe J; Vervenne B; Akl MA; Xue S; Shi K; Sportelli G; Belcari N; Hustinx R; Vanhove C; Karp JS Eur J Nucl Med Mol Imaging; 2023 Oct; 50(12):3558-3571. PubMed ID: 37466650 [TBL] [Abstract][Full Text] [Related]
50. A multiplexed TOF and DOI capable PET detector using a binary position sensitive network. Bieniosek MF; Cates JW; Levin CS Phys Med Biol; 2016 Nov; 61(21):7639-7651. PubMed ID: 27740946 [TBL] [Abstract][Full Text] [Related]
51. Design and proof of concept of a double-panel TOF-PET system. Gonzalez-Montoro A; Pavón N; Barberá J; Cuarella N; González AJ; Jiménez-Serrano S; Lucero A; Moliner L; Sánchez D; Vidal K; Benlloch JM EJNMMI Phys; 2024 Aug; 11(1):73. PubMed ID: 39174856 [TBL] [Abstract][Full Text] [Related]
52. Simulation study on 3D convolutional neural networks for time-of-flight prediction in monolithic PET detectors using digitized waveforms. Maebe J; Vandenberghe S Phys Med Biol; 2022 Jun; 67(12):. PubMed ID: 35617948 [No Abstract] [Full Text] [Related]
53. Resolution estimation in different monolithic PET detectors using neural networks. Belov MV; Kozlov VA; Tskhay VS; Zavertyaev MV Phys Med; 2023 Feb; 106():102527. PubMed ID: 36610177 [TBL] [Abstract][Full Text] [Related]
54. SiPM signal readout for inter-crystal scatter event identification in PET detectors. Park H; Lee JS Phys Med Biol; 2020 Oct; 65(20):205010. PubMed ID: 32702670 [TBL] [Abstract][Full Text] [Related]
55. Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET. Cates JW; Choong WS Phys Med Biol; 2022 Sep; 67(19):. PubMed ID: 35961297 [TBL] [Abstract][Full Text] [Related]
56. Model of the point spread function of monolithic scintillator PET detectors for perpendicular incidence. Maas MC; van der Laan DJ; van Eijk CW; Schaart DR; Beekman FJ; Bruyndonckx P; Lemaître C Med Phys; 2010 Apr; 37(4):1904-13. PubMed ID: 20443512 [TBL] [Abstract][Full Text] [Related]
57. Depth of interaction determination in monolithic scintillator with double side SiPM readout. Morrocchi M; Ambrosi G; Bisogni MG; Bosi F; Boretto M; Cerello P; Ionica M; Liu B; Pennazio F; Piliero MA; Pirrone G; Postolache V; Wheadon R; Del Guerra A EJNMMI Phys; 2017 Dec; 4(1):11. PubMed ID: 28211032 [TBL] [Abstract][Full Text] [Related]
58. Timing, Energy, and 3-D Spatial Resolution of the BING PET Detector Module. Hunter W; Dolinsky S; Kinahan P; Miyaoka R IEEE Trans Radiat Plasma Med Sci; 2023 Jan; 7(1):1-10. PubMed ID: 36644761 [TBL] [Abstract][Full Text] [Related]
59. A CNN-based four-layer DOI encoding detector using LYSO and BGO scintillators for small animal PET imaging. He W; Zhao Y; Zhao X; Huang W; Zhang L; Prout DL; Chatziioannou AF; Ren Q; Gu Z Phys Med Biol; 2023 Apr; 68(9):. PubMed ID: 37040784 [No Abstract] [Full Text] [Related]
60. Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes. Li X; Lockhart C; Lewellen TK; Miyaoka RS IEEE Trans Nucl Sci; 2011; 58(3):590-596. PubMed ID: 22685348 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]