These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 38533765)

  • 21. Investigation of the wear and corrosion behaviors of Ti5Al2.5Fe and Ti6Al4V alloys produced by mechanical alloying method in simulated body fluid environment.
    Simsek I; Ozyurek D
    Mater Sci Eng C Mater Biol Appl; 2019 Jan; 94():357-363. PubMed ID: 30423718
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An electrochemical impedance investigation of the behaviour of anodically oxidised titanium in human plasma and cognate fluids, relevant to dental applications.
    Bozzini B; Carlino P; D'Urzo L; Pepe V; Mele C; Venturo F
    J Mater Sci Mater Med; 2008 Nov; 19(11):3443-53. PubMed ID: 18584125
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The Use of Electrochemical Methods to Determine the Effect of Nitrides of Alloying Elements on the Electrochemical Properties of Titanium β-Alloys.
    Jírů J; Hybášek V; Vlčák P; Fojt J
    Int J Mol Sci; 2023 Jan; 24(2):. PubMed ID: 36675171
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A surface-engineered multifunctional TiO
    Lin Z; Wu S; Liu X; Qian S; Chu PK; Zheng Y; Cheung KMC; Zhao Y; Yeung KWK
    Acta Biomater; 2019 Nov; 99():495-513. PubMed ID: 31518705
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Impact of scandium on mechanical properties, corrosion behavior, friction and wear performance, and cytotoxicity of a β-type Ti-24Nb-38Zr-2Mo alloy for orthopedic applications.
    Tong X; Sun Q; Zhang D; Wang K; Dai Y; Shi Z; Li Y; Dargusch M; Huang S; Ma J; Wen C; Lin J
    Acta Biomater; 2021 Oct; 134():791-803. PubMed ID: 34332105
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Corrosion-wear of β-Ti alloy TMZF (Ti-12Mo-6Zr-2Fe) in simulated body fluid.
    Yang X; Hutchinson CR
    Acta Biomater; 2016 Sep; 42():429-439. PubMed ID: 27397494
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Growth of a TiNb adhesion interlayer for bioactive coatings.
    Tolde Z; Starý V; Cvrček L; Vandrovcová M; Remsa J; Daniš S; Krčil J; Bačáková L; Špatenka P
    Mater Sci Eng C Mater Biol Appl; 2017 Nov; 80():652-658. PubMed ID: 28866212
    [TBL] [Abstract][Full Text] [Related]  

  • 28. New Zr-25Ti-xMo alloys for dental implant application: Properties characterization and surface analysis.
    Wei C; Luo L; Wu Z; Zhang J; Su S; Zhan Y
    J Mech Behav Biomed Mater; 2020 Nov; 111():104017. PubMed ID: 32818772
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Determination of structural, mechanical and corrosion properties of Nb2O5 and (NbyCu 1-y)Ox thin films deposited on Ti6Al4V alloy substrates for dental implant applications.
    Mazur M; Kalisz M; Wojcieszak D; Grobelny M; Mazur P; Kaczmarek D; Domaradzki J
    Mater Sci Eng C Mater Biol Appl; 2015 Feb; 47():211-21. PubMed ID: 25492191
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Corrosion and bioactivity performance of graphene oxide coating on TiNb shape memory alloys in simulated body fluid.
    Saud SN; Hosseinian S R; Bakhsheshi-Rad HR; Yaghoubidoust F; Iqbal N; Hamzah E; Ooi CHR
    Mater Sci Eng C Mater Biol Appl; 2016 Nov; 68():687-694. PubMed ID: 27524069
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Albumin coatings by alternating current electrophoretic deposition for improving corrosion resistance and bioactivity of titanium implants.
    Höhn S; Braem A; Neirinck B; Virtanen S
    Mater Sci Eng C Mater Biol Appl; 2017 Apr; 73():798-807. PubMed ID: 28183674
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Corrosion Behavior of Nitrided Layer of Ti6Al4V Titanium Alloy by Hollow Cathodic Plasma Source Nitriding.
    Zhang L; Shao M; Zhang Z; Yi X; Yan J; Zhou Z; Fang D; He Y; Li Y
    Materials (Basel); 2023 Apr; 16(8):. PubMed ID: 37109798
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Optimization of anti-wear and anti-bacterial properties of beta TiNb alloy via controlling duty cycle in open-air laser nitriding.
    Chang X; Smith GC; Quinn J; Carson L; Chan CW; Lee S
    J Mech Behav Biomed Mater; 2020 Oct; 110():103913. PubMed ID: 32957212
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of mechanical properties, in vitro corrosion resistance and biocompatibility of Gum Metal in the context of implant applications.
    Golasiński KM; Detsch R; Szklarska M; Łosiewicz B; Zubko M; Mackiewicz S; Pieczyska EA; Boccaccini AR
    J Mech Behav Biomed Mater; 2021 Mar; 115():104289. PubMed ID: 33388535
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An electrochemical investigation of TMJ implant metal alloys in an artificial joint fluid environment: the influence of pH variation.
    Royhman D; Radhakrishnan R; Yuan JC; Mathew MT; Mercuri LG; Sukotjo C
    J Craniomaxillofac Surg; 2014 Oct; 42(7):1052-61. PubMed ID: 24548869
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparative analysis of corrosion resistance between beta titanium and Ti-6Al-4V alloys: A systematic review.
    Dias Corpa Tardelli J; Bolfarini C; Cândido Dos Reis A
    J Trace Elem Med Biol; 2020 Dec; 62():126618. PubMed ID: 32663743
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment.
    Rosalbino F; Delsante S; Borzone G; Scavino G
    J Mater Sci Mater Med; 2012 May; 23(5):1129-37. PubMed ID: 22382735
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monitoring of titanium base alloys-biofluids interface.
    Popa MV; Demetrescu I; Suh SH; Vasilescu E; Drob P; Ionita D; Vasilescu C
    Bioelectrochemistry; 2007 Nov; 71(2):126-34. PubMed ID: 17409027
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Elucidating the corrosion-related degradation mechanisms of a Ti-6Al-4V dental implant.
    Chen X; Shah K; Dong S; Peterson L; Callagon La Plante E; Sant G
    Dent Mater; 2020 Mar; 36(3):431-441. PubMed ID: 31992484
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Accelerated corrosion of 316L stainless steel in simulated body fluids in the presence of H
    Xu W; Yu F; Yang L; Zhang B; Hou B; Li Y
    Mater Sci Eng C Mater Biol Appl; 2018 Nov; 92():11-19. PubMed ID: 30184732
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.