134 related articles for article (PubMed ID: 38538166)
1. Failure to Terminate Ventricular Fibrillation With Multiple Implantable Cardioverter-Defibrillator Shocks Caused by Shock Polarity. Thomas G; Cheung JW JACC Clin Electrophysiol; 2024 Mar; 10(3):611-619. PubMed ID: 38538166 [No Abstract] [Full Text] [Related]
2. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations). Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697 [TBL] [Abstract][Full Text] [Related]
3. [Efficacy and safety of implantable cardioverter defibrillator avoiding routine defibrillation threshold testing]. Liu Q; Zhou S; Qi S; Zeng G; Ma X; Huang H Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2009 Nov; 34(11):1132-5. PubMed ID: 19952404 [TBL] [Abstract][Full Text] [Related]
4. Antitachycardia pacing therapy for the successful treatment of lead fracture. Bhimani AA; Deeprasertkul P; Nannapaneni N; Carayannopoulos GN J Cardiovasc Electrophysiol; 2015 Feb; 26(2):228-9. PubMed ID: 25354719 [No Abstract] [Full Text] [Related]
5. Catastrophic failure of Durata ICD lead due to high-voltage short during shock delivery. Schloss EJ; Krebs ME; Gupta M Heart Rhythm; 2014 Oct; 11(10):1733-4. PubMed ID: 24931635 [No Abstract] [Full Text] [Related]
6. High dispersion of ventricular repolarization after an implantable defibrillator shock predicts induction of ventricular fibrillation as well as unsuccessful defibrillation. Moubarak JB; Karasik PE; Fletcher RD; Franz MR J Am Coll Cardiol; 2000 Feb; 35(2):422-7. PubMed ID: 10676690 [TBL] [Abstract][Full Text] [Related]
7. Implantable cardioverter-defibrillator therapy before death: high risk for painful shocks at end of life. Kinch Westerdahl A; Sjöblom J; Mattiasson AC; Rosenqvist M; Frykman V Circulation; 2014 Jan; 129(4):422-9. PubMed ID: 24243857 [TBL] [Abstract][Full Text] [Related]
8. Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Programming in Patients With a Left Ventricular Assist Device. Richardson TD; Hale L; Arteaga C; Xu M; Keebler M; Schlendorf K; Danter M; Shah A; Lindenfeld J; Ellis CR J Am Heart Assoc; 2018 Feb; 7(5):. PubMed ID: 29475875 [TBL] [Abstract][Full Text] [Related]
9. Inappropriate implantable cardioverter-defibrillator therapy due to the detection of premature ventricular complexes. Goldberger JJ; Horvath G; Challapalli R; Kadish AH Pacing Clin Electrophysiol; 1999 May; 22(5):825-8. PubMed ID: 10353148 [TBL] [Abstract][Full Text] [Related]
10. Implantable cardioverter-defibrillator shocks in dying patients: disturbing data from beyond the grave. Lampert R Circulation; 2014 Jan; 129(4):414-6. PubMed ID: 24243856 [No Abstract] [Full Text] [Related]
11. Subcutaneous Implantable Cardioverter Defibrillator Lead Repositioning for Preventing Inappropriate Shocks Due to Myopotential Oversensing in a Post-Fulminant Myocarditis Patient. Sasaki T; Nakamura K; Naito S Int Heart J; 2019 Mar; 60(2):466-469. PubMed ID: 30745542 [TBL] [Abstract][Full Text] [Related]
12. Refractoriness to subcutaneous implantable cardioverter defibrillator after frequent therapies for ventricular fibrillation storms in a Brugada syndrome case. Nakao Y; Suenari K; Yamashiro K; Nakagawa H; Shiode N BMC Cardiovasc Disord; 2020 Mar; 20(1):134. PubMed ID: 32169057 [TBL] [Abstract][Full Text] [Related]
13. Causes and Prevention of Inappropriate Implantable Cardioverter-Defibrillator Shocks. Kulkarni N; Link MS Card Electrophysiol Clin; 2018 Mar; 10(1):67-74. PubMed ID: 29428143 [TBL] [Abstract][Full Text] [Related]
15. Termination of ventricular tachycardia by far-field stimulation in humans: a feasibility study. Lawo T; Schrader J; Buddensiek M; Schweika O; Mügge A; Bösche LI Pacing Clin Electrophysiol; 2010 Dec; 33(12):1540-7. PubMed ID: 21039638 [TBL] [Abstract][Full Text] [Related]
16. Recurrence of ventricular tachycardia degeneration by low-energy implantable cardioverter-defibrillator shocks: a case report. Cagli KE; Guray U; Akpinar I; Sen N; Aras D; Topaloglu S J Electrocardiol; 2010; 43(1):68-70. PubMed ID: 19446839 [TBL] [Abstract][Full Text] [Related]
17. Inappropriate shock from a subcutaneous implantable cardioverter-defibrillator due to transcutaneous electrical nerve stimulation. Miller MA; Palaniswamy C; Sharma D; Reddy VY Heart Rhythm; 2015 Jul; 12(7):1702-3. PubMed ID: 25889810 [No Abstract] [Full Text] [Related]
18. Ventricular fibrillation in patients without significant structural heart disease: a multicenter experience with implantable cardioverter-defibrillator therapy. Meissner MD; Lehmann MH; Steinman RT; Mosteller RD; Akhtar M; Calkins H; Cannom DS; Epstein AE; Fogoros RN; Liem LB J Am Coll Cardiol; 1993 May; 21(6):1406-12. PubMed ID: 8473649 [TBL] [Abstract][Full Text] [Related]
19. Should catheter ablation be the preferred therapy for reducing ICD shocks?: Ventricular tachycardia in patients with an implantable defibrillator warrants catheter ablation. Kuck KH Circ Arrhythm Electrophysiol; 2009 Dec; 2(6):713-20; discussion 720. PubMed ID: 20009082 [No Abstract] [Full Text] [Related]
20. Repetitive shock therapy of subcutaneous implantable cardioverter defibrillators in a patient with idiopathic ventricular fibrillation: What is the mechanism? Hasegawa K; Miyazaki S; Ishikawa E; Mukai M; Aoyama D; Nodera M; Kaseno K; Tada H J Cardiovasc Electrophysiol; 2019 Oct; 30(10):2121-2124. PubMed ID: 31332856 [No Abstract] [Full Text] [Related] [Next] [New Search]