BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 38544968)

  • 1. Portable and Autonomous PEDOT-Modified Flexible Paper-Based Methanol Fuel Cell Sensing Platform Applied to L1CAM Recombinant Protein Detection.
    Carneiro LPT; Pinto AMFR; Ivanou D; Mendes AM; Sales MGF
    ACS Appl Polym Mater; 2024 Mar; 6(6):3207-3221. PubMed ID: 38544968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A passive direct methanol fuel cell as transducer of an electrochemical sensor, applied to the detection of carcinoembryonic antigen.
    Carneiro LPT; Ferreira NS; Tavares APM; Pinto AMFR; Mendes A; Sales MGF
    Biosens Bioelectron; 2021 Mar; 175():112877. PubMed ID: 33309216
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flexible All-Solid-State Direct Methanol Fuel Cells with High Specific Power Density.
    Sun S; Zhao M; Wang Q; Xue S; Huang Q; Yu N; Wu Y
    Small; 2023 Mar; 19(12):e2205835. PubMed ID: 36634982
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Autonomous electrochemical biosensors: A new vision to direct methanol fuel cells.
    Sales MGF; Brandão L
    Biosens Bioelectron; 2017 Dec; 98():428-436. PubMed ID: 28711825
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A State-of-Art on the Development of Nafion-Based Membrane for Performance Improvement in Direct Methanol Fuel Cells.
    Ng WW; Thiam HS; Pang YL; Chong KC; Lai SO
    Membranes (Basel); 2022 May; 12(5):. PubMed ID: 35629832
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single wall carbon nanotube supports for portable direct methanol fuel cells.
    Girishkumar G; Hall TD; Vinodgopal K; Kamat PV
    J Phys Chem B; 2006 Jan; 110(1):107-14. PubMed ID: 16471506
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Poly (3, 4-ethylene dioxythiophene) Supported Palladium Catalyst prepared by Galvanic Replacement Reaction for Methanol Tolerant Oxygen Reduction.
    M PR; Berchmans S
    Sci Rep; 2019 Dec; 9(1):19184. PubMed ID: 31844318
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A selective electrocatalyst-based direct methanol fuel cell operated at high concentrations of methanol.
    Feng Y; Liu H; Yang J
    Sci Adv; 2017 Jun; 3(6):e1700580. PubMed ID: 28695199
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Constructing a Cathode Catalyst Layer of a Passive Direct Methanol Fuel Cell with Highly Hydrophilic Carbon Aerogel for Improved Water Management.
    Yuan W; Hou C; Zhang X; Zhong S; Luo Z; Mo D; Zhang Y; Liu X
    ACS Appl Mater Interfaces; 2019 Oct; 11(41):37626-37634. PubMed ID: 31553159
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-Performance Direct Methanol Fuel Cells with Precious-Metal-Free Cathode.
    Li Q; Wang T; Havas D; Zhang H; Xu P; Han J; Cho J; Wu G
    Adv Sci (Weinh); 2016 Nov; 3(11):1600140. PubMed ID: 27980990
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Graphene/Poly(3,4-ethylenedioxythiophene) Hybrid as an Anode for High-Performance Microbial Fuel Cells.
    Wang Y; Zhao CE; Sun D; Zhang JR; Zhu JJ
    Chempluschem; 2013 Aug; 78(8):823-829. PubMed ID: 31986676
    [TBL] [Abstract][Full Text] [Related]  

  • 12. PtRu/Ti anodes with varying Pt ratio: Ru ratio prepared by electrodeposition for the direct methanol fuel cell.
    Shao ZG; Zhu F; Lin WF; Christensen PA; Zhang H
    Phys Chem Chem Phys; 2006 Jun; 8(23):2720-6. PubMed ID: 16763704
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Studies on an ultrasonic atomization feed direct methanol fuel cell.
    Wu C; Liu L; Tang K; Chen T
    Ultrason Sonochem; 2017 Jan; 34():60-66. PubMed ID: 27773285
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Carbon-Supported Pd and PdFe Alloy Catalysts for Direct Methanol Fuel Cell Cathodes.
    Rivera Gavidia LM; Sebastián D; Pastor E; Aricò AS; Baglio V
    Materials (Basel); 2017 May; 10(6):. PubMed ID: 28772937
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Direct Methanol (or Ethanol) Fuel Cell as Enzymatic or Non-Enzymatic Device, Used to Check Ethanol in Several Pharmaceutical and Forensic Samples.
    Tomassetti M; Angeloni R; Marchiandi S; Castrucci M; Sammartino MP; Campanella L
    Sensors (Basel); 2018 Oct; 18(11):. PubMed ID: 30360499
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reduced graphene oxide modified smart conducting paper for cancer biosensor.
    Kumar S; Kumar S; Srivastava S; Yadav BK; Lee SH; Sharma JG; Doval DC; Malhotra BD
    Biosens Bioelectron; 2015 Nov; 73():114-122. PubMed ID: 26057732
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Textile Based Electrochromic Cells Prepared with PEDOT: PSS and Gelled Electrolyte.
    Graßmann C; Mann M; Van Langenhove L; Schwarz-Pfeiffer A
    Sensors (Basel); 2020 Oct; 20(19):. PubMed ID: 33036136
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Growth and electrochromic properties of poly(3,4-ethylenedioxythiophene) layer on TiO2 nanoparticles.
    Baek J; Kim Y; Kim E
    J Nanosci Nanotechnol; 2008 Sep; 8(9):4851-5. PubMed ID: 19049123
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High Methanol Electro-Oxidation Using PtCo/Reduced Graphene Oxide (rGO) Anode Nanocatalysts in Direct Methanol Fuel Cell.
    Baronia R; Goel J; Singhal SK
    J Nanosci Nanotechnol; 2019 Jul; 19(7):4315-4322. PubMed ID: 30765012
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Processable enzyme-hybrid conductive polymer composites for electrochemical biosensing.
    Liu Y; Turner APF; Zhao M; Mak WC
    Biosens Bioelectron; 2018 Feb; 100():374-381. PubMed ID: 28946109
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.