BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 38564013)

  • 1. Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium?
    Kutzler M; Patterson JT; Anz H; Siahaan J; Warner SJ; Gary JL
    Eur J Orthop Surg Traumatol; 2024 May; 34(4):2147-2153. PubMed ID: 38564013
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.
    Lujan TJ; Henderson CE; Madey SM; Fitzpatrick DC; Marsh JL; Bottlang M
    J Orthop Trauma; 2010 Mar; 24(3):156-62. PubMed ID: 20182251
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of callus formation in distal femur fractures after carbon fiber composite versus stainless steel plate fixation.
    Byun SE; Vintimilla DR; Bedeir YH; Dean CS; Parry JA; Hak DJ; Mauffrey C
    Eur J Orthop Surg Traumatol; 2020 Aug; 30(6):1103-1107. PubMed ID: 32356122
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.
    Krieg JC
    J Orthop Trauma; 2011 Feb; 25(2):e21; author reply e21-2. PubMed ID: 21245704
    [No Abstract]   [Full Text] [Related]  

  • 5. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.
    Kandemir U; Augat P; Konowalczyk S; Wipf F; von Oldenburg G; Schmidt U
    J Orthop Trauma; 2017 Aug; 31(8):e241-e246. PubMed ID: 28394844
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiographic Healing of Far Cortical Locking Constructs in Distal Femur Fractures: A Comparative Study With Standard Locking Plates.
    Plumarom Y; Wilkinson BG; Marsh JL; Willey MC; An Q; Gao Y; Karam MD
    J Orthop Trauma; 2019 Jun; 33(6):277-283. PubMed ID: 30908342
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stabilization of distal femur fractures with intramedullary nails and locking plates: differences in callus formation.
    Henderson CE; Lujan T; Bottlang M; Fitzpatrick DC; Madey SM; Marsh JL
    Iowa Orthop J; 2010; 30():61-8. PubMed ID: 21045973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Predictive factors of distal femoral fracture nonunion after lateral locked plating: a retrospective multicenter case-control study of 283 fractures.
    Rodriguez EK; Boulton C; Weaver MJ; Herder LM; Morgan JH; Chacko AT; Appleton PT; Zurakowski D; Vrahas MS
    Injury; 2014 Mar; 45(3):554-9. PubMed ID: 24275357
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression.
    Marshall T; Momaya A; Eberhardt A; Chaudhari N; Hunt TR
    J Hand Surg Am; 2015 Oct; 40(10):2032-8. PubMed ID: 26253601
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 2010 mid-America Orthopaedic Association Physician in Training Award: healing complications are common after locked plating for distal femur fractures.
    Henderson CE; Lujan TJ; Kuhl LL; Bottlang M; Fitzpatrick DC; Marsh JL
    Clin Orthop Relat Res; 2011 Jun; 469(6):1757-65. PubMed ID: 21424831
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Motion Predicts Clinical Callus Formation: Construct-Specific Finite Element Analysis of Supracondylar Femoral Fractures.
    Elkins J; Marsh JL; Lujan T; Peindl R; Kellam J; Anderson DD; Lack W
    J Bone Joint Surg Am; 2016 Feb; 98(4):276-84. PubMed ID: 26888675
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial.
    Couzens GB; Peters SE; Cutbush K; Hope B; Taylor F; James CD; Rankin CR; Ross M
    BMC Musculoskelet Disord; 2014 Mar; 15():74. PubMed ID: 24612524
    [TBL] [Abstract][Full Text] [Related]  

  • 13. What Is the Likelihood of Union and Frequency of Complications After Parallel Plating and Supplemental Bone Grafting for Resistant Distal Femoral Nonunions?
    Gavaskar AS; Tummala NC; Reddy CR; Gopalan H; Srinivasan P
    Clin Orthop Relat Res; 2024 Feb; 482(2):362-372. PubMed ID: 37638842
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Elastic stable intramedullary nailing (ESIN) in paediatric femur and tibia shaft fractures: Comparison between titanium and stainless steel nails.
    Marengo L; Nasto LA; Michelis MB; Boero S
    Injury; 2018 Nov; 49 Suppl 3():S8-S11. PubMed ID: 30415674
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bridge Plate Fixation of Distal Femur Fractures: Defining Deficient Radiographic Callus Formation and Its Associations.
    Crutcher WL; Magnusson EA; Griffith KM; Alford CA; Nielsen ED; Elkins JM; Lujan TJ; Kleweno CP; Lack WD
    J Orthop Trauma; 2023 Oct; 37(10):475-479. PubMed ID: 37127901
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures. An experimental study in dogs.
    Uhthoff HK; Bardos DI; Liskova-Kiar M
    J Bone Joint Surg Br; 1981; 63-B(3):427-84. PubMed ID: 7263759
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures.
    Harvin WH; Oladeji LO; Della Rocca GJ; Murtha YM; Volgas DA; Stannard JP; Crist BD
    Injury; 2017 Nov; 48(11):2597-2601. PubMed ID: 28889934
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Healing results of periprosthetic distal femur fractures treated with far cortical locking technology: a preliminary retrospective study.
    Ries Z; Hansen K; Bottlang M; Madey S; Fitzpatrick D; Marsh JL
    Iowa Orthop J; 2013; 33():7-11. PubMed ID: 24027454
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes of distal femoral fractures treated with minimally invasive plate osteosynthesis versus open reduction internal fixation with combined locking plate and interfragmentary screws.
    Wang SH; Wu CC; Li WT; Shen HC; Lin LC; Pan RY
    Int J Surg; 2019 May; 65():107-112. PubMed ID: 30951872
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study.
    Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U
    Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.