These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 38582388)

  • 1. Cholesterol Interference in the Assessment of Vitamin D Status: A Canadian Health Measures Survey Biobank Project.
    Weiler HA; Bielecki A; Fu W; Demonty I; Brooks SP
    J Nutr; 2024 May; 154(5):1676-1685. PubMed ID: 38582388
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variation in clinical vitamin D status by DiaSorin Liaison and LC-MS/MS in the presence of elevated 25-OH vitamin D2.
    de Koning L; Al-Turkmani MR; Berg AH; Shkreta A; Law T; Kellogg MD
    Clin Chim Acta; 2013 Jan; 415():54-8. PubMed ID: 22975531
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Standardization of misleading immunoassay based 25-hydroxyvitamin D levels with liquid chromatography tandem-mass spectrometry in a large cohort study.
    Schöttker B; Jansen EH; Haug U; Schomburg L; Köhrle J; Brenner H
    PLoS One; 2012; 7(11):e48774. PubMed ID: 23133659
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Variability in vitamin D assays impairs clinical assessment of vitamin D status.
    Lai JK; Lucas RM; Banks E; Ponsonby AL;
    Intern Med J; 2012 Jan; 42(1):43-50. PubMed ID: 21395958
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Methodological issues in assessing plasma 25-hydroxyvitamin D concentration in newborn infants.
    Gallo S; Comeau K; Agellon S; Vanstone C; Sharma A; Jones G; L'abbé M; Khamessan A; Weiler H; Rodd C
    Bone; 2014 Apr; 61():186-90. PubMed ID: 24473373
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 25-hydroxy-Vitamin D status: limitations in comparison and clinical interpretation of serum-levels across different assay methods.
    Enko D; Fridrich L; Rezanka E; Stolba R; Ernst J; Wendler I; Fabian D; Hauptlorenz S; Halwachs-Baumann G
    Clin Lab; 2014; 60(9):1541-50. PubMed ID: 25291951
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Standardized serum 25-hydroxyvitamin D concentrations are inversely associated with cardiometabolic disease in U.S. adults: a cross-sectional analysis of NHANES, 2001-2010.
    Al-Khalidi B; Kimball SM; Rotondi MA; Ardern CI
    Nutr J; 2017 Feb; 16(1):16. PubMed ID: 28241878
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance evaluation of four 25-hydroxyvitamin D assays to measure 25-hydroxyvitamin D2.
    Freeman J; Wilson K; Spears R; Shalhoub V; Sibley P
    Clin Biochem; 2015 Nov; 48(16-17):1097-104. PubMed ID: 26054580
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry.
    Kocak FE; Ozturk B; Isiklar OO; Genc O; Unlu A; Altuntas I
    Biochem Med (Zagreb); 2015; 25(3):430-8. PubMed ID: 26526462
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the new restandardized Abbott Architect 25-OH Vitamin D assay in vitamin D-insufficient and vitamin D-supplemented individuals.
    Annema W; Nowak A; von Eckardstein A; Saleh L
    J Clin Lab Anal; 2018 May; 32(4):e22328. PubMed ID: 28926129
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the analytical performance of Unicel DXI 800 for the Total 25 (OH) Vitamin D measurements.
    Ozcan N; Ucar F; Arzuhal AE; Bulut E; Ozturk A; Taslipinar Yavuz M; Temel I; Erden G
    Clin Biochem; 2016 Apr; 49(6):486-491. PubMed ID: 26655254
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Impact of Sample Type on Vitamin D Quantification and Clinical Classification during Pregnancy.
    Harvey SM; Murphy VE; Gibson PG; Clarke M; Jensen ME
    Nutrients; 2020 Dec; 12(12):. PubMed ID: 33352934
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Four automated 25-OH total vitamin D immunoassays and commercial liquid chromatography tandem-mass spectrometry in Finnish population.
    Koivula MK; Matinlassi N; Laitinen P; Risteli J
    Clin Lab; 2013; 59(3-4):397-405. PubMed ID: 23724631
    [TBL] [Abstract][Full Text] [Related]  

  • 14. State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods.
    Farrell CJ; Martin S; McWhinney B; Straub I; Williams P; Herrmann M
    Clin Chem; 2012 Mar; 58(3):531-42. PubMed ID: 22230812
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of automated 25-OH vitamin D immunoassays with liquid chromatography isotope dilution tandem mass spectrometry.
    Koivula MK; Turpeinen U; Laitinen P; Risteli J
    Clin Lab; 2012; 58(11-12):1253-61. PubMed ID: 23289196
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The vitamin D status of the US population from 1988 to 2010 using standardized serum concentrations of 25-hydroxyvitamin D shows recent modest increases.
    Schleicher RL; Sternberg MR; Lacher DA; Sempos CT; Looker AC; Durazo-Arvizu RA; Yetley EA; Chaudhary-Webb M; Maw KL; Pfeiffer CM; Johnson CL
    Am J Clin Nutr; 2016 Aug; 104(2):454-61. PubMed ID: 27385610
    [TBL] [Abstract][Full Text] [Related]  

  • 17. National Estimates of Serum Total 25-Hydroxyvitamin D and Metabolite Concentrations Measured by Liquid Chromatography-Tandem Mass Spectrometry in the US Population during 2007-2010.
    Schleicher RL; Sternberg MR; Looker AC; Yetley EA; Lacher DA; Sempos CT; Taylor CL; Durazo-Arvizu RA; Maw KL; Chaudhary-Webb M; Johnson CL; Pfeiffer CM
    J Nutr; 2016 May; 146(5):1051-61. PubMed ID: 27052537
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of serum total vitamin D (25-OH) using automated immunoassay in comparison [corrected] with liquid chromatography tandem-mass spectrometry.
    Shin SY; Kwon MJ; Song J; Park H; Woo HY
    J Clin Lab Anal; 2013 Jul; 27(4):284-9. PubMed ID: 23852785
    [TBL] [Abstract][Full Text] [Related]  

  • 19. LC-MS/MS based 25(OH)D status in a large Southern European outpatient cohort: gender- and age-specific differences.
    Giuliani S; Barbieri V; Di Pierro AM; Rossi F; Widmann T; Lucchiari M; Pusceddu I; Pilz S; Obermayer-Pietsch B; Herrmann M
    Eur J Nutr; 2019 Sep; 58(6):2511-2520. PubMed ID: 30088075
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of Vitamin D Standardization Program protocols for standardizing serum 25-hydroxyvitamin D data: a case study of the program's potential for national nutrition and health surveys.
    Cashman KD; Kiely M; Kinsella M; Durazo-Arvizu RA; Tian L; Zhang Y; Lucey A; Flynn A; Gibney MJ; Vesper HW; Phinney KW; Coates PM; Picciano MF; Sempos CT
    Am J Clin Nutr; 2013 Jun; 97(6):1235-42. PubMed ID: 23615829
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.