These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 38584522)
1. Mobile bedside ductus arteriosus closure in severely premature neonates using only echocardiographic guidance. Georgiev S; Tanase D; Eicken A; Hörer J; Zahn E; Borgmann K; Renner D; Ewert P Catheter Cardiovasc Interv; 2024 May; 103(6):934-942. PubMed ID: 38584522 [TBL] [Abstract][Full Text] [Related]
2. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS. Morville P; Akhavi A Catheter Cardiovasc Interv; 2017 Oct; 90(4):612-617. PubMed ID: 28471089 [TBL] [Abstract][Full Text] [Related]
3. Percutaneous closure of patent ductus arteriosus in premature infants: A French national survey. Malekzadeh-Milani S; Akhavi A; Douchin S; Dauphin C; Chalard A; Mauran P; Bouvaist H; Bonnet D; Boudjemline Y Catheter Cardiovasc Interv; 2020 Jan; 95(1):71-77. PubMed ID: 31609068 [TBL] [Abstract][Full Text] [Related]
4. Transcatheter occlusion of the patent ductus arteriosus in premature infants weighing less than 1200 g. Morville P; Douchin S; Bouvaist H; Dauphin C Arch Dis Child Fetal Neonatal Ed; 2018 May; 103(3):F198-F201. PubMed ID: 29066474 [TBL] [Abstract][Full Text] [Related]
5. Incidence and fate of device-related left pulmonary artery stenosis and aortic coarctation in small infants undergoing transcatheter patent ductus arteriosus closure. Tomasulo CE; Gillespie MJ; Munson D; Demkin T; O'Byrne ML; Dori Y; Smith CL; Rome JJ; Glatz AC Catheter Cardiovasc Interv; 2020 Oct; 96(4):889-897. PubMed ID: 32339400 [TBL] [Abstract][Full Text] [Related]
6. Transcatheter Closure of Patent Ductus Arteriosus in Extremely Premature Newborns: Early Results and Midterm Follow-Up. Zahn EM; Peck D; Phillips A; Nevin P; Basaker K; Simmons C; McRae ME; Early T; Garg R JACC Cardiovasc Interv; 2016 Dec; 9(23):2429-2437. PubMed ID: 27931595 [TBL] [Abstract][Full Text] [Related]
7. A novel technique for transcatheter patent ductus arteriosus closure in extremely preterm infants using commercially available technology. Zahn EM; Nevin P; Simmons C; Garg R Catheter Cardiovasc Interv; 2015 Feb; 85(2):240-8. PubMed ID: 24782400 [TBL] [Abstract][Full Text] [Related]
8. Novel use of the medtronic micro vascular plug for PDA closure in preterm infants. Wang-Giuffre EW; Breinholt JP Catheter Cardiovasc Interv; 2017 May; 89(6):1059-1065. PubMed ID: 27860173 [TBL] [Abstract][Full Text] [Related]
9. Percutaneous Patent Ductus Arteriosus (PDA) Closure in Very Preterm Infants: Feasibility and Complications. Backes CH; Cheatham SL; Deyo GM; Leopold S; Ball MK; Smith CV; Garg V; Holzer RJ; Cheatham JP; Berman DP J Am Heart Assoc; 2016 Feb; 5(2):. PubMed ID: 26873689 [TBL] [Abstract][Full Text] [Related]
10. Transcatheter patent arterial duct closure in premature infants: A new technique to ease access to the patent arterial duct, with particular benefit for the tricuspid valve. Meot M; Gaudin R; Szezepanski I; Bajolle F; Bonnet D; Malekzadeh-Milani S Arch Cardiovasc Dis; 2021; 114(6-7):482-489. PubMed ID: 34312100 [TBL] [Abstract][Full Text] [Related]
11. Early experience with the Micro Plug Set for preterm patent ductus arteriosus closure. Heyden CM; El-Said HG; Moore JW; Guyon PW; Katheria AC; Ratnayaka K Catheter Cardiovasc Interv; 2020 Dec; 96(7):1439-1444. PubMed ID: 32979038 [TBL] [Abstract][Full Text] [Related]
12. Initial clinical experience with the Medtronic Micro Vascular Plug™ in transcatheter occlusion of PDAs in extremely premature infants. Sathanandam S; Justino H; Waller BR; Radtke W; Qureshi AM Catheter Cardiovasc Interv; 2017 May; 89(6):1051-1058. PubMed ID: 27888552 [TBL] [Abstract][Full Text] [Related]
13. The new Occlutech(®) patent ductus arteriosus occluder: Single centre experience. Boudjemline Y Arch Cardiovasc Dis; 2016; 109(6-7):384-9. PubMed ID: 26988839 [TBL] [Abstract][Full Text] [Related]
14. Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients ≥700 grams. Sathanandam SK; Gutfinger D; O'Brien L; Forbes TJ; Gillespie MJ; Berman DP; Armstrong AK; Shahanavaz S; Jones TK; Morray BH; Rockefeller TA; Justino H; Nykanen DG; Zahn EM Catheter Cardiovasc Interv; 2020 Nov; 96(6):1266-1276. PubMed ID: 32433821 [TBL] [Abstract][Full Text] [Related]
15. Transcatheter Patent Ductus Arteriosus Occlusion in Small Infants. Schwartz MC; Nykanen D; Winner LH; Perez J; McMahan M; Munro HM; Suguna Narasimhulu S Congenit Heart Dis; 2016 Dec; 11(6):647-655. PubMed ID: 27225896 [TBL] [Abstract][Full Text] [Related]
17. Percutaneous closure of a large patent ductus arteriosus in a preterm newborn weighing 1400 g without using arterial sheath: an innovative technique. Garg G; Garg V; Prakash A Cardiol Young; 2018 Mar; 28(3):494-497. PubMed ID: 29233212 [TBL] [Abstract][Full Text] [Related]
18. Closure of patent ductus arteriosus in children, small infants, and premature babies with Amplatzer duct occluder II additional sizes: multicenter study. Sungur M; Karakurt C; Ozbarlas N; Baspinar O Catheter Cardiovasc Interv; 2013 Aug; 82(2):245-52. PubMed ID: 23460349 [TBL] [Abstract][Full Text] [Related]
19. Percutaneous closure of patent ductus arteriosus in children using amplatzer duct occluder II: relationship between PDA type and risk of device protrusion into the descending aorta. Masri S; El Rassi I; Arabi M; Tabbakh A; Bitar F Catheter Cardiovasc Interv; 2015 Aug; 86(2):E66-72. PubMed ID: 26032159 [TBL] [Abstract][Full Text] [Related]
20. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder. Bilici M; Demir F; Akın A; Türe M; Balık H; Kuyumcu M Pediatr Cardiol; 2017 Dec; 38(8):1598-1605. PubMed ID: 28828684 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]