These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. On electrical potentials observed at a distance from intracranial electrode contacts. Wennberg R Clin Neurophysiol; 2010 Feb; 121(2):259-62; author reply 262-3. PubMed ID: 19951844 [No Abstract] [Full Text] [Related]
3. The conductivity of the human skull: results of in vivo and in vitro measurements. Oostendorp TF; Delbeke J; Stegeman DF IEEE Trans Biomed Eng; 2000 Nov; 47(11):1487-92. PubMed ID: 11077742 [TBL] [Abstract][Full Text] [Related]
4. Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull. Ryynänen OR; Hyttinen JA; Malmivuo JA IEEE Trans Biomed Eng; 2006 Sep; 53(9):1851-8. PubMed ID: 16941841 [TBL] [Abstract][Full Text] [Related]
5. Current density distributions, field distributions and impedance analysis of segmented deep brain stimulation electrodes. Wei XF; Grill WM J Neural Eng; 2005 Dec; 2(4):139-47. PubMed ID: 16317238 [TBL] [Abstract][Full Text] [Related]
10. Improvement of spatial selectivity and decrease of mutual information of tri-polar concentric ring electrodes. Koka K; Besio WG J Neurosci Methods; 2007 Sep; 165(2):216-22. PubMed ID: 17681379 [TBL] [Abstract][Full Text] [Related]
11. Does combing the scalp reduce scalp electrode impedances? Mahajan Y; McArthur G J Neurosci Methods; 2010 May; 188(2):287-9. PubMed ID: 20211649 [TBL] [Abstract][Full Text] [Related]
12. A physiologically plausible spatio-temporal model for EEG signals recorded with intracerebral electrodes in human partial epilepsy. Cosandier-Rimélé D; Badier JM; Chauvel P; Wendling F IEEE Trans Biomed Eng; 2007 Mar; 54(3):380-8. PubMed ID: 17355049 [TBL] [Abstract][Full Text] [Related]
13. An equivalent current source model and laplacian weighted minimum norm current estimates of brain electrical activity. He B; Yao D; Lian J; Wu D IEEE Trans Biomed Eng; 2002 Apr; 49(4):277-88. PubMed ID: 11942719 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of μECoG electrode arrays in the minipig: experimental procedure and neurosurgical approach. Gierthmuehlen M; Ball T; Henle C; Wang X; Rickert J; Raab M; Freiman T; Stieglitz T; Kaminsky J J Neurosci Methods; 2011 Oct; 202(1):77-86. PubMed ID: 21896285 [TBL] [Abstract][Full Text] [Related]
15. Effect of electrode density and measurement noise on the spatial resolution of cortical potential distribution. Ryynänen OR; Hyttinen JA; Laarne PH; Malmivuo JA IEEE Trans Biomed Eng; 2004 Sep; 51(9):1547-54. PubMed ID: 15376503 [TBL] [Abstract][Full Text] [Related]
16. Equivalent source estimation based on the calculation of the electric field from depth EEG data. Lemieux L; Leduc A IEEE Trans Biomed Eng; 1992 Aug; 39(8):805-17. PubMed ID: 1505994 [TBL] [Abstract][Full Text] [Related]
17. [Re-evaluation of using acupuncture needle as sphenoidal electrode in temporal lobe epilepsy]. Chu NS Acta Neurol Taiwan; 2009 Jun; 18(2):137-42. PubMed ID: 19673369 [TBL] [Abstract][Full Text] [Related]
18. Effects of electrode density and electrolyte spreading in dense array electroencephalographic recording. Greischar LL; Burghy CA; van Reekum CM; Jackson DC; Pizzagalli DA; Mueller C; Davidson RJ Clin Neurophysiol; 2004 Mar; 115(3):710-20. PubMed ID: 15036067 [TBL] [Abstract][Full Text] [Related]
19. Dense array EEG: methodology and new hypothesis on epilepsy syndromes. Holmes MD Epilepsia; 2008; 49 Suppl 3():3-14. PubMed ID: 18304251 [TBL] [Abstract][Full Text] [Related]
20. [Accuracy of the spatial localization of the sources of brain bioelectrical activity in a model homogeneous unrestricted environment]. Frolov AA; Ponomarev VN Zh Vyssh Nerv Deiat Im I P Pavlova; 1988; 38(5):897-904. PubMed ID: 3223073 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]