These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Prognostic value of aortic valve calcification in non-severe aortic stenosis with preserved ejection fraction. Ye Z; Scott CG; Gajjar RA; Foley T; Clavel MA; Nkomo VT; Luis SA; Miranda WR; Padang R; Pislaru SV; Enriquez-Sarano M; Michelena HI Eur Heart J Cardiovasc Imaging; 2024 Sep; 25(10):1432-1440. PubMed ID: 38833585 [TBL] [Abstract][Full Text] [Related]
7. Assessment of aortic valve calcium load by multidetector computed tomography. Anatomical validation, impact of scanner settings and incremental diagnostic value. Boulif J; Gerber B; Slimani A; Lazam S; de Meester C; Piérard S; Pasquet A; Pouleur AC; Vancraeynest D; El Khoury G; de Kerchove L; Noirhomme P; Vanoverschelde JL J Cardiovasc Comput Tomogr; 2017; 11(5):360-366. PubMed ID: 28803719 [TBL] [Abstract][Full Text] [Related]
8. Visual scoring of aortic valve calcifications on low-dose CT in lung cancer screening. Zhu Y; Wang Y; Gioia WE; Yip R; Jirapatnakul AC; Chung MS; Yankelevitz DF; Henschke CI Eur Radiol; 2020 May; 30(5):2658-2668. PubMed ID: 32040729 [TBL] [Abstract][Full Text] [Related]
9. Impact of Different Iterations of Devices and Degree of Aortic Valve Calcium on Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation. Kong WK; van Rosendael PJ; van der Kley F; de Weger A; Kamperidis V; Regeer MV; Marsan NA; Bax JJ; Delgado V Am J Cardiol; 2016 Aug; 118(4):567-71. PubMed ID: 27328953 [TBL] [Abstract][Full Text] [Related]
10. Aortic Valve Calcification Density Measured by MDCT in the Assessment of Aortic Stenosis Severity. Powers A; Ali M; Lavoie N; Haujir A; Mogensen NSB; Ludwig S; Øvrehus KA; Tastet L; Rhéaume C; Schofer N; Dahl JS; Clavel MA Circ Cardiovasc Imaging; 2024 May; 17(5):e016267. PubMed ID: 38771899 [TBL] [Abstract][Full Text] [Related]
11. Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography. Messika-Zeitoun D; Aubry MC; Detaint D; Bielak LF; Peyser PA; Sheedy PF; Turner ST; Breen JF; Scott C; Tajik AJ; Enriquez-Sarano M Circulation; 2004 Jul; 110(3):356-62. PubMed ID: 15249504 [TBL] [Abstract][Full Text] [Related]
12. Association between aortic valve calcification measured on non-contrast computed tomography and aortic valve stenosis in the general population. Paulsen NH; Carlsen BB; Dahl JS; Carter-Storch R; Christensen NL; Khurrami L; Møller JE; Lindholt JS; Diederichsen AC J Cardiovasc Comput Tomogr; 2016; 10(4):309-15. PubMed ID: 27247181 [TBL] [Abstract][Full Text] [Related]
13. The association between aortic valve calcification, cardiovascular risk factors, and cardiac size and function in a general population. Khurrami L; Møller JE; Dahl JS; Carter-Storch R; Christensen NL; Pareek M; Lindholt JS; Diederichsen ACP Int J Cardiovasc Imaging; 2021 Feb; 37(2):711-722. PubMed ID: 32915345 [TBL] [Abstract][Full Text] [Related]
15. Impact of aortic valve calcification, as measured by MDCT, on survival in patients with aortic stenosis: results of an international registry study. Clavel MA; Pibarot P; Messika-Zeitoun D; Capoulade R; Malouf J; Aggarval S; Araoz PA; Michelena HI; Cueff C; Larose E; Miller JD; Vahanian A; Enriquez-Sarano M J Am Coll Cardiol; 2014 Sep; 64(12):1202-13. PubMed ID: 25236511 [TBL] [Abstract][Full Text] [Related]
16. Morphologic findings in explanted Hancock II porcine bioprostheses. Butany J; Yu W; Silver MD; David TE J Heart Valve Dis; 1999 Jan; 8(1):4-15. PubMed ID: 10096476 [TBL] [Abstract][Full Text] [Related]
17. Impact of aortic valve calcification severity and impaired left ventricular function on 3-year results of patients undergoing transcatheter aortic valve replacement. Koos R; Reinartz S; Mahnken AH; Herpertz R; Lotfi S; Autschbach R; Marx N; Hoffmann R Eur Radiol; 2013 Dec; 23(12):3253-61. PubMed ID: 23821024 [TBL] [Abstract][Full Text] [Related]
18. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement. Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034 [TBL] [Abstract][Full Text] [Related]
19. Aortic valve calcification as a predictor of location and severity of paravalvular regurgitation after transcatheter aortic valve implantation. Koh EY; Lam KY; Bindraban NR; Cocchieri R; Planken RN; Koch KT; Baan J; de Mol BA; Marquering HA Interact Cardiovasc Thorac Surg; 2015 Mar; 20(3):345-50. PubMed ID: 25487234 [TBL] [Abstract][Full Text] [Related]
20. Identifying fragile calcifications of the aortic valve in transcatheter aortic valve replacement: iodine concentration of aortic valvular calcification by spectral CT. Park S; Cho Y; Oh YW; Ko M; Lim DS; Yu CW; Park SM; Kim MN; Hwang SH Eur Radiol; 2023 Mar; 33(3):1963-1972. PubMed ID: 36112191 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]