122 related articles for article (PubMed ID: 38608495)
21. Reusable evanescent wave DNA biosensor for rapid, highly sensitive, and selective detection of mercury ions.
Long F; Gao C; Shi HC; He M; Zhu AN; Klibanov AM; Gu AZ
Biosens Bioelectron; 2011 Jun; 26(10):4018-23. PubMed ID: 21550227
[TBL] [Abstract][Full Text] [Related]
22. A gas reporting whole-cell microbial biosensor system for rapid on-site detection of mercury contamination in soils.
Liu Y; Guo M; Du R; Chi J; He X; Xie Z; Huang K; Luo Y; Xu W
Biosens Bioelectron; 2020 Dec; 170():112660. PubMed ID: 33011618
[TBL] [Abstract][Full Text] [Related]
23. An oligonucleotide-functionalized carbon nanotube chemiresistor for sensitive detection of mercury in saliva.
Wordofa DN; Ramnani P; Tran TT; Mulchandani A
Analyst; 2016 Apr; 141(9):2756-60. PubMed ID: 26902487
[TBL] [Abstract][Full Text] [Related]
24. Highly Sensitive Luminescent Bioassay Using Recombinant
Wang GH; Cheng CY; Tsai TH; Chiang PK; Chung YC
Biosensors (Basel); 2021 Sep; 11(10):. PubMed ID: 34677313
[TBL] [Abstract][Full Text] [Related]
25. Engineering of a Au-sensor to develop a Hg-specific, sensitive and robust whole-cell biosensor for on-site water monitoring.
Mendoza JI; Soncini FC; Checa SK
Chem Commun (Camb); 2020 Jun; 56(48):6590-6593. PubMed ID: 32406434
[TBL] [Abstract][Full Text] [Related]
26. A sensitive whole-cell biosensor for the simultaneous detection of a broad-spectrum of toxic heavy metal ions.
Cerminati S; Soncini FC; Checa SK
Chem Commun (Camb); 2015 Apr; 51(27):5917-20. PubMed ID: 25730473
[TBL] [Abstract][Full Text] [Related]
27. Engineering the Ultrasensitive Visual Whole-Cell Biosensors by Evolved MerR and 5' UTR for Detection of Ultratrace Mercury.
Zhu K; Chen D; Cai Y; Zhang T; Ma J; Bao L; Zhao F; Wu L; Chen S
Environ Sci Technol; 2023 Nov; 57(44):16964-16973. PubMed ID: 37863904
[TBL] [Abstract][Full Text] [Related]
28. Sensitive and Specific Whole-Cell Biosensor for Arsenic Detection.
Jia X; Bu R; Zhao T; Wu K
Appl Environ Microbiol; 2019 Jun; 85(11):. PubMed ID: 30952659
[TBL] [Abstract][Full Text] [Related]
29. Orthogonal paper biosensor for mercury(II) combining bioluminescence and colorimetric smartphone detection.
Lopreside A; Montali L; Wang B; Tassoni A; Ferri M; Calabretta MM; Michelini E
Biosens Bioelectron; 2021 Dec; 194():113569. PubMed ID: 34438340
[TBL] [Abstract][Full Text] [Related]
30. DNA-functionalized upconversion nanoparticles as biosensors for rapid, sensitive, and selective detection of Hg(2+) in complex matrices.
Huang LJ; Yu RQ; Chu X
Analyst; 2015 Aug; 140(15):4987-90. PubMed ID: 26040459
[TBL] [Abstract][Full Text] [Related]
31. A GFP-based bacterial biosensor with chromosomally integrated sensing cassette for quantitative detection of Hg(II) in environment.
Priyadarshi H; Alam A; Gireesh-Babu P; Das R; Kishore P; Kumar S; Chaudhari A
J Environ Sci (China); 2012; 24(5):963-8. PubMed ID: 22893977
[TBL] [Abstract][Full Text] [Related]
32. Aptamer-Based Electrochemical Biosensor for Mercury Ions Detection Using AuNPs-Modified Glass Carbon Electrode.
Liu Y; Deng Y; Li T; Chen Z; Chen H; Li S; Liu H
J Biomed Nanotechnol; 2018 Dec; 14(12):2156-2161. PubMed ID: 30305222
[TBL] [Abstract][Full Text] [Related]
33. E. coli biosensor based on modular GFP and luxI/luxR cyclic amplification circuit for sensitive detection of lysine.
Wang W; Zhang J; Tao H; Lv X; Deng Y; Li X
Anal Bioanal Chem; 2022 Dec; 414(29-30):8299-8307. PubMed ID: 36253476
[TBL] [Abstract][Full Text] [Related]
34. Sensitive and Specific Cadmium Biosensor Developed by Reconfiguring Metal Transport and Leveraging Natural Gene Repositories.
He MY; Lin YJ; Kao YL; Kuo P; Grauffel C; Lim C; Cheng YS; Chou HD
ACS Sens; 2021 Mar; 6(3):995-1002. PubMed ID: 33444502
[TBL] [Abstract][Full Text] [Related]
35. Visual detection of Hg
Wang D; Zheng Y; Fan X; Xu L; Pang T; Liu T; Liang L; Huang S; Xiao Q
J Biosci Bioeng; 2020 Feb; 129(2):223-228. PubMed ID: 31492609
[TBL] [Abstract][Full Text] [Related]
36. A Disposable Electrochemical Biosensor Based on Screen-Printed Carbon Electrodes Modified with Silver Nanowires/HPMC/Chitosan/Urease for the Detection of Mercury (II) in Water.
Saenchoopa A; Klangphukhiew S; Somsub R; Talodthaisong C; Patramanon R; Daduang J; Daduang S; Kulchat S
Biosensors (Basel); 2021 Sep; 11(10):. PubMed ID: 34677307
[TBL] [Abstract][Full Text] [Related]
37. A "turn-off" fluorescent biosensor for the detection of mercury (II) based on graphite carbon nitride.
Li J; Wang H; Guo Z; Wang Y; Ma H; Ren X; Du B; Wei Q
Talanta; 2017 Jan; 162():46-51. PubMed ID: 27837856
[TBL] [Abstract][Full Text] [Related]
38. Biosensors for detection of mercury in contaminated soils.
Bontidean I; Mortari A; Leth S; Brown NL; Karlson U; Larsen MM; Vangronsveld J; Corbisier P; Csöregi E
Environ Pollut; 2004 Sep; 131(2):255-62. PubMed ID: 15234092
[TBL] [Abstract][Full Text] [Related]
39. A nano-graphite-DNA hybrid sensor for magnified fluorescent detection of mercury(II) ions in aqueous solution.
Wei Y; Li B; Wang X; Duan Y
Analyst; 2014 Apr; 139(7):1618-21. PubMed ID: 24555179
[TBL] [Abstract][Full Text] [Related]
40. A Simple Metallothionein-Based Biosensor for Enhanced Detection of Arsenic and Mercury.
Irvine GW; Tan SN; Stillman MJ
Biosensors (Basel); 2017 Mar; 7(1):. PubMed ID: 28335390
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]