117 related articles for article (PubMed ID: 38614015)
1. Sustentaculum fracture fixation with lateral plate or medial screw fixation are equivalent.
Roytman GR; Salameh M; Rizzo SE; Dhodapkar MM; Tommasini SM; Wiznia DH; Yoo BJ
Injury; 2024 Jun; 55(6):111532. PubMed ID: 38614015
[TBL] [Abstract][Full Text] [Related]
2. Fractures of the sustentaculum tali.
Dürr C; Zwipp H; Rammelt S
Oper Orthop Traumatol; 2013 Dec; 25(6):569-78. PubMed ID: 24306047
[TBL] [Abstract][Full Text] [Related]
3. [Study on sustentaculum tali screw placement for constant fragment of calcaneal fracture].
Sun Z; Zhao C; Chen Y; Li N; Zhang T; Xin J; Ma X
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 May; 32(5):581-586. PubMed ID: 29806346
[TBL] [Abstract][Full Text] [Related]
4. Computational Biomechanical Analysis of Postoperative Calcaneal Fractures with Different Placement of the Sustentaculum Screw.
Qiang MF; Singh RK; Chen YX; Zhang K; Jia XY; Chen S; Wang SG; Wang X; Shi ZM
Orthop Surg; 2020 Apr; 12(2):661-667. PubMed ID: 32053281
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical Analysis of Stability of Posterior Antiglide Plating in Osteoporotic Pronation Abduction Ankle Fracture Model With Posterior Tibial Fragment.
Hartwich K; Lorente Gomez A; Pyrc J; Gut R; Rammelt S; Grass R
Foot Ankle Int; 2017 Jan; 38(1):58-65. PubMed ID: 27672062
[TBL] [Abstract][Full Text] [Related]
6. Mechanical Comparison of Headless Screw Fixation and Locking Plate Fixation for Talar Neck Fractures.
Karakasli A; Hapa O; Erduran M; Dincer C; Cecen B; Havitcioglu H
J Foot Ankle Surg; 2015; 54(5):905-9. PubMed ID: 25998471
[TBL] [Abstract][Full Text] [Related]
7. Supination Adduction Vertical Medial Malleolar Fracture Fixation with Buttress Plating vs a Novel Screw-Only Construct: A Cadaveric Biomechanical Study.
Testa EJ; Walsh D; Patel D; Kahan LG; Modest J; Schilkowsky R; Hsu R
Foot Ankle Int; 2022 Jun; 43(6):810-817. PubMed ID: 35293239
[TBL] [Abstract][Full Text] [Related]
8. A Biomechanical Comparison of Fifth Metatarsal Jones Fracture Fixation Methods.
Duplantier NL; Mitchell RJ; Zambrano S; Stone AC; Delgado DA; Lambert BS; Moreno MR; Harris JD; McCulloch PC; Lintner DM; Varner KE
Am J Sports Med; 2018 Apr; 46(5):1220-1227. PubMed ID: 29466679
[TBL] [Abstract][Full Text] [Related]
9. Maximizing safety in screw placement for posterior facet fixation in calcaneus fractures: a cadaveric radio-anatomical study.
Phisitkul P; Sullivan JP; Goetz JE; Marsh JL
Foot Ankle Int; 2013 Sep; 34(9):1279-85. PubMed ID: 23598855
[TBL] [Abstract][Full Text] [Related]
10. Locking vs. non-locking plate fixation in comminuted talar neck fractures: a biomechanical study using cadaveric specimens.
Maxwell L; Nava T; Norrish A; Kobezda T; Pizzimenti M; Brassett C; Pasapula C
Foot (Edinb); 2024 Jun; 59():102084. PubMed ID: 38513373
[TBL] [Abstract][Full Text] [Related]
11. Antiglide plating of vertical medial malleolus fractures provides stiffer initial fixation than bicortical or unicortical screw fixation.
Wegner AM; Wolinsky PR; Robbins MA; Garcia TC; Maitra S; Amanatullah DF
Clin Biomech (Bristol, Avon); 2016 Jan; 31():29-32. PubMed ID: 26482240
[TBL] [Abstract][Full Text] [Related]
12. Lag screw fixation of medial malleolar fractures: a biomechanical, radiographic, and clinical comparison of unicortical partially threaded lag screws and bicortical fully threaded lag screws.
Ricci WM; Tornetta P; Borrelli J
J Orthop Trauma; 2012 Oct; 26(10):602-6. PubMed ID: 22437423
[TBL] [Abstract][Full Text] [Related]
13. Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study.
Sakai R; Uchino M; Yoneo T; Ohtaki Y; Minehara H; Matsuura T; Gomi T; Ujihira M
J Orthop Surg Res; 2017 Feb; 12(1):34. PubMed ID: 28228100
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical Performance of Lateral Versus Dual Locking Plates for Calcaneal Fractures.
Maxwell AB; Owen JR; Gilbert TM; Romash MM; Wayne JS; Adelaar RS
J Foot Ankle Surg; 2015; 54(5):830-5. PubMed ID: 25960057
[TBL] [Abstract][Full Text] [Related]
15. Ability of modern distal tibia plates to stabilize comminuted pilon fracture fragments: Is dual plate fixation necessary?
Penny P; Swords M; Heisler J; Cien A; Sands A; Cole P
Injury; 2016 Aug; 47(8):1761-9. PubMed ID: 27264277
[TBL] [Abstract][Full Text] [Related]
16. Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures.
Schliemann B; Seifert R; Rosslenbroich SB; Theisen C; Wähnert D; Raschke MJ; Weimann A
J Shoulder Elbow Surg; 2015 Dec; 24(12):1968-73. PubMed ID: 26255200
[TBL] [Abstract][Full Text] [Related]
17. Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture.
Huh J; Glisson RR; Matsumoto T; Easley ME
Foot Ankle Int; 2016 Apr; 37(4):411-8. PubMed ID: 26637274
[TBL] [Abstract][Full Text] [Related]
18. Comminuted talar neck fractures: a mechanical comparison of fixation techniques.
Attiah M; Sanders DW; Valdivia G; Cooper I; Ferreira L; MacLeod MD; Johnson JA
J Orthop Trauma; 2007 Jan; 21(1):47-51. PubMed ID: 17211269
[TBL] [Abstract][Full Text] [Related]
19. Bone plate fixation ability on the dorsal and lateral sides of a metacarpal shaft transverse fracture.
Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT
J Orthop Surg Res; 2021 Jul; 16(1):441. PubMed ID: 34233702
[TBL] [Abstract][Full Text] [Related]
20. Comparison of Dorsal Plate Fixation Versus Intramedullary Headless Screw Fixation of Unstable Metacarpal Shaft Fractures: A Biomechanical Study.
Melamed E; Hinds RM; Gottschalk MB; Kennedy OD; Capo JT
Hand (N Y); 2016 Dec; 11(4):421-426. PubMed ID: 28149208
[No Abstract] [Full Text] [Related]
[Next] [New Search]