These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 38616127)
1. Influence of a mesial cantilever on stress, strain, and axial force in fixed partial dentures with a distally tilted implant in the atrophic posterior maxilla. Fan X; Chen L; Chen Q; Wang F; Wu Y; Sun Y J Prosthodont Res; 2024 Oct; 68(4):615-623. PubMed ID: 38616127 [TBL] [Abstract][Full Text] [Related]
2. Finite element analysis of implant-supported prosthesis with pontic and cantilever in the posterior maxilla. de Souza Batista VE; Verri FR; Almeida DA; Santiago Junior JF; Lemos CA; Pellizzer EP Comput Methods Biomech Biomed Engin; 2017 May; 20(6):663-670. PubMed ID: 28349769 [TBL] [Abstract][Full Text] [Related]
3. Influence of Implant Inclination and Prosthetic Abutment Type on the Biomechanics of Implant-Supported Fixed Partial Dentures. Poletto-Neto V; Tretto PHW; Zen BM; Bacchi A; Dos Santos MBF J Oral Implantol; 2019 Oct; 45(5):343-350. PubMed ID: 31429636 [TBL] [Abstract][Full Text] [Related]
4. Role of implant configurations supporting three-unit fixed partial denture on mandibular bone response: biological-data-based finite element study. Yoda N; Liao Z; Chen J; Sasaki K; Swain M; Li Q J Oral Rehabil; 2016 Sep; 43(9):692-701. PubMed ID: 27224022 [TBL] [Abstract][Full Text] [Related]
5. [Three-dimensional finite element analysis of the effect of the location and diameter of implants on the stress distribution in three-unit implant-supported posterior cantilever fixed partial dentures under dynamic loads]. Lü J; Liu C; Lan J; Gao X Hua Xi Kou Qiang Yi Xue Za Zhi; 2013 Dec; 31(6):552-6. PubMed ID: 24437284 [TBL] [Abstract][Full Text] [Related]
6. Biomechanical Comparison of Different Implant Inclinations and Cantilever Lengths in All-on-4 Treatment Concept by Three-Dimensional Finite Element Analysis. Ozan O; Kurtulmus-Yilmaz S Int J Oral Maxillofac Implants; 2018; 33(1):64-71. PubMed ID: 29340344 [TBL] [Abstract][Full Text] [Related]
7. The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures. Yokoyama S; Wakabayashi N; Shiota M; Ohyama T J Prosthet Dent; 2004 Mar; 91(3):234-40. PubMed ID: 15060492 [TBL] [Abstract][Full Text] [Related]
8. Biomechanical behavior of implant retained prostheses in the posterior maxilla using different materials: a finite element study. Aboelfadl A; Keilig L; Ebeid K; Ahmed MAM; Nouh I; Refaie A; Bourauel C BMC Oral Health; 2024 Apr; 24(1):455. PubMed ID: 38622680 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of Effect of Connector Designs in Implant Tooth-supported Fixed Partial Denture: A Two-dimensional Finite Element Analysis. Gowda S; Quadras DD; Sesappa RS; Katapadi V; Kumar L; Kulkarni D; Mishra N J Contemp Dent Pract; 2018 Jun; 19(6):669-674. PubMed ID: 29959294 [TBL] [Abstract][Full Text] [Related]
10. Finite element analysis on dental implant-supported prostheses without passive fit. Kunavisarut C; Lang LA; Stoner BR; Felton DA J Prosthodont; 2002 Mar; 11(1):30-40. PubMed ID: 11935508 [TBL] [Abstract][Full Text] [Related]
11. Influence of occlusal forces on stress distribution in preloaded dental implant screws. Alkan I; Sertgöz A; Ekici B J Prosthet Dent; 2004 Apr; 91(4):319-25. PubMed ID: 15116032 [TBL] [Abstract][Full Text] [Related]
13. FEA of Peri-Implant Stresses in Fixed Partial Denture Prostheses with Cantilevers. Alencar SM; Nogueira LB; Leal de Moura W; Rubo JH; Saymo de Oliveira Silva T; Martins GA; Moura CD J Prosthodont; 2017 Feb; 26(2):150-155. PubMed ID: 26588042 [TBL] [Abstract][Full Text] [Related]
14. Stress Distribution on the Prosthetic Screws in the All-on-4 Concept: A Three-Dimensional Finite Element Analysis. Oh JH; Kim YS; Lim JY; Choi BH J Oral Implantol; 2020 Feb; 46(1):3-12. PubMed ID: 31647687 [TBL] [Abstract][Full Text] [Related]
15. Biomechanical comparison of axial and tilted implants for mandibular full-arch fixed prostheses. Kim KS; Kim YL; Bae JM; Cho HW Int J Oral Maxillofac Implants; 2011; 26(5):976-84. PubMed ID: 22010079 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of strain at the terminal abutment site of a fixed mandibular implant prosthesis during cantilever loading. Rodriguez AM; Aquilino SA; Lund PS; Ryther JS; Southard TE J Prosthodont; 1993 Jun; 2(2):93-102. PubMed ID: 8242172 [TBL] [Abstract][Full Text] [Related]
17. Biomechanics of cantilever fixed partial dentures in shortened dental arch therapy. Romeed SA; Fok SL; Wilson NH J Prosthodont; 2004 Jun; 13(2):90-100. PubMed ID: 15210004 [TBL] [Abstract][Full Text] [Related]
18. Biomechanical evaluation of screw- and cement-retained implant-supported prostheses: a nonlinear finite element analysis. Silva GC; Cornacchia TM; de Magalhães CS; Bueno AC; Moreira AN J Prosthet Dent; 2014 Dec; 112(6):1479-88. PubMed ID: 25062583 [TBL] [Abstract][Full Text] [Related]
19. Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features. Cho SY; Huh YH; Park CJ; Cho LR Int J Oral Maxillofac Implants; 2018; 33(2):319-327. PubMed ID: 29534119 [TBL] [Abstract][Full Text] [Related]
20. The effects of loading on the preload and dimensions of the abutment screw for a 3-unit cantilever-fixed prosthesis design. Setia G; Yousef H; Ehrenberg D; Luke A; Weiner S Implant Dent; 2013 Aug; 22(4):414-21. PubMed ID: 23842028 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]