These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
133 related articles for article (PubMed ID: 3861879)
1. [JIS draft proposal for lung ventilators for medical use]. Sato T Masui; 1985 Jun; 34(6):873-85. PubMed ID: 3861879 [No Abstract] [Full Text] [Related]
4. The features and design of ventilators. Inkster JS Prog Pediatr Surg; 1971; 3():99-104. PubMed ID: 5292158 [No Abstract] [Full Text] [Related]
5. [Analysis and realization of new methods of testing the artificial ventilation of lungs (AVL) equipment]. Gal'perin IuSh; Alkhimova LR; Safronov AIu Med Tekh; 2003; (4):3-11. PubMed ID: 14518108 [TBL] [Abstract][Full Text] [Related]
6. [Artificial ventilation in newborns and infants (author's transl)]. Rügheimer E Z Prakt Anasth Wiederbeleb Intensivther; 1973 Jan; 8(1):31-40. PubMed ID: 4520467 [No Abstract] [Full Text] [Related]
7. [Theoretical and experimental pressure behavior and volume distribution in a model of the lung during artificial ventilation]. Cancelli C; De Renzo A; Giardina B; Vatta F Minerva Anestesiol; 1971 Jan; 37(1):2-47. PubMed ID: 5284409 [No Abstract] [Full Text] [Related]
9. Mechanical ventilation of the newborn infant. I. Daily WJ; Smith PC Curr Probl Pediatr; 1971 Jun; 1(8):1-37. PubMed ID: 4943609 [No Abstract] [Full Text] [Related]
10. The role of the physical characteristics of the respirator in artificial ventilation of the newborn. Mattila MA Acta Anaesthesiol Scand Suppl; 1974; 56():1-107. PubMed ID: 4614646 [No Abstract] [Full Text] [Related]
11. [Field 5. Safety practices procedures for mechanical ventilation. French-speaking Society of Intensive Care. French Society of Anesthesia and Resuscitation]. Girault C; Auriant I; Jaber S Ann Fr Anesth Reanim; 2008 Oct; 27(10):e77-89. PubMed ID: 18951756 [TBL] [Abstract][Full Text] [Related]
12. Pediatric mechanical ventilators. An evaluation of performance characteristics. Mathewson HS; Linn CR; Gish GB J Kans Med Soc; 1983 May; 84(5):255-62, 282. PubMed ID: 6575108 [No Abstract] [Full Text] [Related]
13. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Bachiller PR; McDonough JM; Feldman JM Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850 [TBL] [Abstract][Full Text] [Related]
14. Intensive care ventilators. Health Devices; 1998; 27(9-10):308-62. PubMed ID: 9809256 [TBL] [Abstract][Full Text] [Related]
15. Correction of error in respiratory resistance measurements made with the flow-interruption technique during mechanical ventilation: evaluation of the puritan bennett 7200 and 840 ventilators. Lit LM; Doelken P; Mayo PH Respir Care; 2004 Sep; 49(9):1022-8. PubMed ID: 15329173 [TBL] [Abstract][Full Text] [Related]
16. [The performance of respirator alarms during simulated critical events in CMV/IPPV artificial respiration]. Bender HJ; Frankenberger H; Ryll C; Albrecht MD Anaesthesist; 1993 Jun; 42(6):365-75. PubMed ID: 8342746 [TBL] [Abstract][Full Text] [Related]
17. Disposable adult breathing circuits for use with critical care ventilators. Health Devices; 1994 Apr; 23(4):104-29. PubMed ID: 10147135 [TBL] [Abstract][Full Text] [Related]
18. Air medical transport in 1991. Jeffs M Respir Care; 1992 Jul; 37(7):796-803; discussion 803-6. PubMed ID: 10145674 [No Abstract] [Full Text] [Related]
19. Respiratory mechanics derived from signals in the ventilator circuit. Lucangelo U; Bernabé F; Blanch L Respir Care; 2005 Jan; 50(1):55-65; discussion 65-7. PubMed ID: 15636645 [TBL] [Abstract][Full Text] [Related]