These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 38630711)

  • 21. Cementless Tapered Wedge Femoral Stems Decrease Subsidence in Obese Patients Compared to Traditional Fit-and-Fill Stems.
    Grant TW; Lovro LR; Licini DJ; Warth LC; Ziemba-Davis M; Meneghini RM
    J Arthroplasty; 2017 Mar; 32(3):891-897. PubMed ID: 27793497
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Risk Factors for Periprosthetic Femur Fracture and Influence of Femoral Fixation Using the Mini-Anterolateral Approach in Primary Total Hip Arthroplasty.
    Herndon CL; Nowell JA; Sarpong NO; Cooper HJ; Shah RP; Geller JA
    J Arthroplasty; 2020 Mar; 35(3):774-778. PubMed ID: 31685395
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Periprosthetic fractures around polished collarless cemented stems: the effect of stem design on fracture pattern.
    Erhardt JB; Khoo PP; Stoffel KK; Yates PJ
    Hip Int; 2013; 23(5):459-64. PubMed ID: 23813164
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Incidence of Periprosthetic Femur Fractures Utilizing the Posterior Approach with a Single Wedge Tapered Stem.
    Formby P; Hong CS; Ryan S; Wellman S; Bolognesi M
    J Surg Orthop Adv; 2019; 28(4):277-280. PubMed ID: 31886764
    [TBL] [Abstract][Full Text] [Related]  

  • 25. How Does Implant Survivorship Vary with Different Corail Femoral Stem Variants? Results of 51,212 Cases with Up to 30 Years Of Follow-up from the Norwegian Arthroplasty Register.
    Melbye SM; Haug SCD; Fenstad AM; Furnes O; Gjertsen JE; Hallan G
    Clin Orthop Relat Res; 2021 Oct; 479(10):2169-2180. PubMed ID: 34427568
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Radiographic and Clinical Outcomes of Modular Tapered Fluted Stems for Femoral Revision for Paprosky III and IV Femoral Defects or Vancouver B2 and B3 Femoral Fractures.
    Otero JE; Martin JR; Rowe TM; Odum SM; Mason JB
    J Arthroplasty; 2020 Apr; 35(4):1069-1073. PubMed ID: 31870582
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Periprosthetic femoral fracture as cause of early revision after short stem hip arthroplasty-a multicentric analysis.
    Kim SM; Han SB; Rhyu KH; Yoo JJ; Oh KJ; Yoo JH; Lee KJ; Lim SJ
    Int Orthop; 2018 Sep; 42(9):2069-2076. PubMed ID: 29651610
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Outcomes of Cerclage Cabling for Intraoperative Calcar Cracks in Cementless Total Hip Arthroplasty Using Broach-Only, Tapered Wedge Stems.
    Park CW; Lim SJ; Ye DH; Park YS
    J Arthroplasty; 2020 Oct; 35(10):3002-3009. PubMed ID: 32553792
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Rectangular Taper Stem Designs Are Associated With a Higher Risk for Periprosthstic Femoral Fractures After Cementless Total Hip Arthroplasty.
    Jeong SJ; Park CW; Cho K; Jeong J; Lim SJ; Park YS
    J Arthroplasty; 2023 Nov; 38(11):2379-2385. PubMed ID: 37271230
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Periprosthetic Femur Fracture Risk: Influenced by Stem Choice, Not Surgical Approach.
    Sershon RA; McDonald JF; Ho H; Hamilton WG
    J Arthroplasty; 2021 Jul; 36(7S):S363-S366. PubMed ID: 33736894
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The Stability of Fixation of Vancouver B2 Periprosthetic Femoral Fractures: Effect of Implantation Technique.
    Frangie R; Han S; Noble PC; Gold JE; Lanfermeijer ND; Reddy KI; Ismaily SK; Su J; Schroder SJ; Rodriguez-Quintana D
    J Arthroplasty; 2023 Jul; 38(7S):S292-S297. PubMed ID: 36933680
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Experimental analysis of early periprosthetic femoral fractures with uncemented straight hip stems.
    Saemann M; Darowski M; Hennicke NS; Bader R; Sander M; Kluess D
    Clin Biomech (Bristol, Avon); 2022 Jan; 91():105543. PubMed ID: 34871913
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Survival and performance of a dual tapered-wedge fully HA-coated press fit femoral stem.
    Yakkanti RR; Greif DN; Berge DJV; Robinson RP
    Arch Orthop Trauma Surg; 2023 Mar; 143(3):1651-1661. PubMed ID: 35239021
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A high risk of postoperative periprosthetic femoral fracture in Dorr type C femurs: a retrospective cohort study with 10-year follow-up data and a preliminary monochromatic image analysis.
    Li M; Zeng Y; Nie Y; Liao K; Pei F; Yang J; Xie H; Shen B
    Int J Surg; 2024 Jan; 110(1):296-305. PubMed ID: 37830949
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Subsidence of Hydroxyapatite-Coated Femoral Stem in Dorr Type C Proximal Femoral Morphology.
    Rattanaprichavej P; Laoruengthana A; Chotanaphuti T; Khuangsirikul S; Phreethanutt C; Pongpirul K
    J Arthroplasty; 2019 Sep; 34(9):2011-2015. PubMed ID: 31182412
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Influence of bone morphology and femur preparation method on the primary stability of hip revision stems.
    Konow T; Schlieker PJ; Lampe F; Ondruschka B; Morlock MM; Huber G
    J Orthop Res; 2023 Jun; 41(6):1283-1290. PubMed ID: 36370133
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Long-term survivorship of a monoblock long cementless stem in revision total hip arthroplasty.
    Herry Y; Viste A; Bothorel H; Desmarchelier R; Fessy MH
    Int Orthop; 2019 Oct; 43(10):2279-2284. PubMed ID: 30276449
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Load transfer and periprosthetic fractures after total hip arthoplasty: Comparison of periprosthetic fractures of femora implanted with cementless distal-load or proximal-load femoral components and measurement of the femoral strain at the time of implantation.
    Schwarz E; Reinisch G; Brandauer A; Aharinejad S; Scharf W; Trieb K
    Clin Biomech (Bristol, Avon); 2018 May; 54():137-142. PubMed ID: 29587147
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Higher periprosthetic fracture rate associated with use of modern uncemented stems compared to cemented stems in femoral neck fractures.
    Song JSA; Dillman D; Wilson D; Dunbar M; Richardson G
    Hip Int; 2019 Mar; 29(2):177-183. PubMed ID: 29682992
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Increased Rates of Late Periprosthetic Fractures in Larger Hydroxyapatite-Coated Cementless Stems: Are Collared Stems a Better Alternative for Total Hip Arthroplasty?
    Tierney J; Jackman E; Holder C; Wall CJ; Wilson CJ
    J Arthroplasty; 2024 Mar; 39(3):744-749. PubMed ID: 37633510
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.