These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 38633932)

  • 1. A Case Report on Iris Disk Positioning on a Custom-Made Ocular Prosthesis Using an Adjustable Trial Frame.
    Naik SG; Akhtarkhavari M; Nagarsekar A; Aras MA; Chitre V
    Cureus; 2024 Mar; 16(3):e56382. PubMed ID: 38633932
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An Innovative Technique of Iris Positioning Using Digital Photographs for Custom Ocular Prosthesis: A Case Report.
    Palanisamy K; Rajagopal P; Fernandes G; Aras M; Chitre V
    Cureus; 2024 Apr; 16(4):e58717. PubMed ID: 38779291
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A simple method of positioning the iris disk on a custom-made ocular prosthesis. A clinical report.
    Guttal SS; Patil NP; Vernekar N; Porwal A
    J Prosthodont; 2008 Apr; 17(3):223-7. PubMed ID: 18047488
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Iris Positioning Using a Grid Attached to a Spring Bow for a Custom Ocular Prosthesis.
    Chamaria A; Aras MA; Chitre V; Costa GCD
    J Clin Diagn Res; 2017 Mar; 11(3):ZD12-ZD13. PubMed ID: 28511522
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An Innovative Method for Iris Positioning in a Prosthetic Eye.
    Belkhode VM; Nimonkar SV; Chaudhary SC; Hakkepatil A; Nimonkar P; Prajapat J
    J Contemp Dent Pract; 2020 Jul; 21(7):815-818. PubMed ID: 33020369
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Alternative Technique of Iris Orientation in a Custom-Made Ocular Prosthesis.
    Bhochhibhoya A; Mishra S; Mathema S; Acharya B; Maskey B
    J Prosthodont; 2019 Jun; 28(5):601-604. PubMed ID: 29067746
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simplified approach for placing the iris disc on a custom made ocular prosthesis: report of four cases.
    Kumar P; Aggrawal H; Singh RD; Chand P; Jurel SK; Alvi HA; Gupta SK
    J Indian Prosthodont Soc; 2014 Mar; 14(1):124-7. PubMed ID: 24605010
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rehabilitation of an ocular defect with intraorbital implant and custom-made prosthesis using digital photography and gridded spectacle.
    Dasgupta D; Das K; Singh R
    J Indian Prosthodont Soc; 2019; 19(3):266-271. PubMed ID: 31462867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fabrication of ocular prosthesis with a digital customization technique - A case report.
    Lanzara R; Thakur A; Viswambaran M; Khattak A
    J Family Med Prim Care; 2019 Mar; 8(3):1239-1242. PubMed ID: 31041281
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A technique for iris disk positioning on a custom ocular prosthesis.
    Abd-Ellah ME; Khamis MM; Neena AF
    J Prosthodont; 2024 Mar; 33(3):301-304. PubMed ID: 37422858
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional orientation of iris in an ocular prosthesis using a customized scale.
    Gupta L; Aparna IN; Dhanasekar B; Prabhu N; Malla N; Agarwal P
    J Prosthodont; 2014 Apr; 23(3):252-5. PubMed ID: 24118216
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Custom-made ocular prosthesis.
    Gunaseelaraj R; Karthikeyan S; Kumar MN; Balamurugan T; Jagadeeshwaran AR
    J Pharm Bioallied Sci; 2012 Aug; 4(Suppl 2):S177-9. PubMed ID: 23066246
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A narrative review on techniques of iris replication in an ocular prosthesis.
    Nimonkar SV; Belkhode VM; Dahihandekar C; Nimonkar PV; Pisulkar S
    J Indian Prosthodont Soc; 2023; 23(1):4-11. PubMed ID: 36588369
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Different techniques in fabrication of ocular prosthesis.
    Cevik P; Dilber E; Eraslan O
    J Craniofac Surg; 2012 Nov; 23(6):1779-81. PubMed ID: 23147321
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rehabilitation of unilateral loss of eye with customized ocular prosthesis: Case series.
    Shrivastava KJ; Shrivastava S; Yadav NS; Gupta S
    Indian J Dent Res; 2020; 31(2):326-330. PubMed ID: 32436918
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prosthetic Rehabilitation of a Patient with Ocular Defect using Semi-customized Prosthesis: A Case Report.
    Putanikar NY; Patil AG; Shetty PK; Nagaral S; Mithaiwala HI
    J Int Oral Health; 2015 Apr; 7(4):81-4. PubMed ID: 25954078
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ocular Defect Rehabilitation Using Photography and Digital Imaging: A Clinical Report.
    Buzayan MM; Ariffin YT; Yunus N; Mahmood WA
    J Prosthodont; 2015 Aug; 24(6):506-10. PubMed ID: 25315047
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Augmented reality filters for iris positioning in orbital prosthesis: A clinical report.
    Puar JK; Narang V; Kaur J
    J Prosthet Dent; 2023 Oct; ():. PubMed ID: 37806943
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A modified technique and simplified laboratory procedure for ocular prosthesis fabrication.
    Kathuria N; Prasad R; Gupta N; Gulati M; Bhide SV
    J Prosthodont Res; 2012 Apr; 56(2):147-50. PubMed ID: 22104621
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prosthetic Rehabilitation of Completely Blind Subject with Bilateral Customised Ocular Prosthesis: A Case Report.
    Pathak C; Pawah S; Singh G; Yadav I; Kundra S
    J Clin Diagn Res; 2017 Jan; 11(1):ZD06-ZD08. PubMed ID: 28274064
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.