BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 38639324)

  • 1. Verifying the nonreporting hemolysis index for potassium, phosphate, magnesium, AST, LDH, iron, CA 19-9, and vitamin D, using Beckman Coulter AU5800 and DxI800 automated analyzers.
    Sheerin S
    Lab Med; 2024 Apr; ():. PubMed ID: 38639324
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods.
    Monneret D; Mestari F; Atlan G; Corlouer C; Ramani Z; Jaffre J; Dever S; Fressart V; Alkouri R; Lamari F; Devilliers C; Imbert-Bismut F; Bonnefont-Rousselot D
    Scand J Clin Lab Invest; 2015 Apr; 75(2):162-9. PubMed ID: 25608598
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of hemolysis index thresholds optimizes detection of clinically significant hemolysis.
    Goyal T; Schmotzer CL
    Am J Clin Pathol; 2015 Apr; 143(4):579-83. PubMed ID: 25780011
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Sensitive Analytes to Hemolysis Interference on an Automated Chemistry Analyzer.
    Marakankadavu Parambu M; Bush V
    J Appl Lab Med; 2024 May; 9(3):558-564. PubMed ID: 38300631
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of hemolysis on clinical chemistry parameters determined with Beckman Coulter tests - detection of clinically significant interference.
    Perović A; Dolčić M
    Scand J Clin Lab Invest; 2019 May; 79(3):154-159. PubMed ID: 30767593
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of the Optimal Wavelength of the Hemolysis Index Measurement.
    Ishiguro A; Nishioka M; Morishige A; Yoneshiro M; Shinkawa K; Fujinaga A; Kobayashi T; Suehiro Y; Yamasaki T
    J Clin Med; 2023 Sep; 12(18):. PubMed ID: 37762805
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers.
    Nikolac Gabaj N; Miler M; Vrtarić A; Hemar M; Filipi P; Kocijančić M; Šupak Smolčić V; Ćelap I; Šimundić AM
    Clin Chem Lab Med; 2018 Apr; 56(5):776-788. PubMed ID: 29315074
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of three different protocols for obtaining hemolysis.
    Nikolac Gabaj N; Miler M; Vrtaric A; Celap I; Bocan M; Filipi P; Radisic Biljak V; Simundic AM; Supak Smolcic V; Kocijancic M
    Clin Chem Lab Med; 2022 Apr; 60(5):714-725. PubMed ID: 35212494
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of hemolysis cut-offs for biochemical and immunochemical analytes according to their value.
    Dupuy AM; Bargnoux AS; Kuster N; Cristol JP; Badiou S
    Clin Chem Lab Med; 2020 Jul; 58(8):1232-1241. PubMed ID: 32267242
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Derivation of sex and age-specific reference intervals for clinical chemistry analytes in healthy Ghanaian adults.
    Bawua SA; Ichihara K; Keatley R; Arko-Mensah J; Ayeh-Kumi PF; Erasmus R; Fobil J
    Clin Chem Lab Med; 2022 Aug; 60(9):1426-1439. PubMed ID: 35786502
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Relationship between sampling volume of primary serum tubes and spurious hemolysis.
    Lippi G; Musa R; Battistelli L; Cervellin G
    Clin Lab; 2012; 58(11-12):1187-91. PubMed ID: 23289188
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Potassium but not lactate dehydrogenase elevation due to in vitro hemolysis is higher in capillary than in venous blood samples.
    Oostendorp M; van Solinge WW; Kemperman H
    Arch Pathol Lab Med; 2012 Oct; 136(10):1262-5. PubMed ID: 23020733
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessing the influence of true hemolysis occurring in patient samples on emergency clinical biochemistry tests results using the VITROS
    Liu S; Li J; Ning L; Wu D; Wei D
    Biomed Rep; 2021 Nov; 15(5):91. PubMed ID: 34631046
    [TBL] [Abstract][Full Text] [Related]  

  • 14. What is the acceptable hemolysis index for the measurements of plasma potassium, LDH and AST?
    Rousseau N; Pige R; Cohen R; Pecquet M
    Ann Biol Clin (Paris); 2016 Jun; 74(3):323-8. PubMed ID: 27159801
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach.
    Vermeer HJ; Steen G; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH
    Clin Chem Lab Med; 2007; 45(1):114-9. PubMed ID: 17243928
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Verification of the hemolysis index measurement: imprecision, accuracy, measuring range, reference interval and impact of implementing analytically and clinically derived sample rejection criteria.
    Gils C; Sandberg MB; Nybo M
    Scand J Clin Lab Invest; 2020 Nov; 80(7):580-589. PubMed ID: 32955365
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemolysis Index Correlations with Plasma-Free Hemoglobin and Plasma Lactate Dehydrogenase in Critically Ill Patients under Extracorporeal Membrane Oxygenation or Mechanical Circulatory Support-A Single-Center Study.
    Zapletal B; Zimpfer D; Schlöglhofer T; Fritzer-Szekeres M; Szekeres T; Bernardi MH; Geilen J; Schultz MJ; Tschernko EM
    Diagnostics (Basel); 2024 Mar; 14(7):. PubMed ID: 38611592
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Hemolysis interferences on frequently required stat analysis: a French multicentric study].
    Poupon C; Lefèvre G; Ngo-François S; Alibeu C; Barbé F; Bourbonneux V; Cartier R; Morin C; Szymanowicz A; Vuillaume I;
    Ann Biol Clin (Paris); 2015; 73(6):705-16. PubMed ID: 26635050
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of selected serum biochemistry measurements between the Nova Prime Plus VET, Nova pHOx Ultra, and Beckman Coulter AU680 analyzers in dogs.
    Nelson C; Constable PD; Connolly SL
    Vet Clin Pathol; 2021 Sep; 50(3):327-341. PubMed ID: 34545580
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the Preanalytical Interference of Hemoglobin, Bilirubin, or Lipids in Therapeutic Drug Monitoring Assays on Beckman Coulter AU Analyzers.
    Li J; Rietschlin J; Miller I; Weber C; Scheidegger M; Barringer S; Kerlin R; Williams J
    Lab Med; 2022 Mar; 53(2):172-176. PubMed ID: 34436600
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.