227 related articles for article (PubMed ID: 38640241)
1. Coin-sized, fully integrated, and minimally invasive continuous glucose monitoring system based on organic electrochemical transistors.
Bai J; Liu D; Tian X; Wang Y; Cui B; Yang Y; Dai S; Lin W; Zhu J; Wang J; Xu A; Gu Z; Zhang S
Sci Adv; 2024 Apr; 10(16):eadl1856. PubMed ID: 38640241
[TBL] [Abstract][Full Text] [Related]
2. Fully integrated wearable microneedle biosensing platform for wide-range and real-time continuous glucose monitoring.
Li L; Zhou Y; Sun C; Zhou Z; Zhang J; Xu Y; Xiao X; Deng H; Zhong Y; Li G; Chen Z; Deng W; Hu X; Wang Y
Acta Biomater; 2024 Feb; 175():199-213. PubMed ID: 38160859
[TBL] [Abstract][Full Text] [Related]
3. Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review.
Saha T; Del Caño R; Mahato K; De la Paz E; Chen C; Ding S; Yin L; Wang J
Chem Rev; 2023 Jun; 123(12):7854-7889. PubMed ID: 37253224
[TBL] [Abstract][Full Text] [Related]
4. Technological Advances of Wearable Device for Continuous Monitoring of
Huang X; Yao C; Huang S; Zheng S; Liu Z; Liu J; Wang J; Chen HJ; Xie X
ACS Sens; 2024 Mar; 9(3):1065-1088. PubMed ID: 38427378
[TBL] [Abstract][Full Text] [Related]
5. Electrochemical glucose sensors in diabetes management: an updated review (2010-2020).
Teymourian H; Barfidokht A; Wang J
Chem Soc Rev; 2020 Nov; 49(21):7671-7709. PubMed ID: 33020790
[TBL] [Abstract][Full Text] [Related]
6. Skin Patchable Sensor Surveillance for Continuous Glucose Monitoring.
Manasa G; Mascarenhas RJ; Shetti NP; Malode SJ; Mishra A; Basu S; Aminabhavi TM
ACS Appl Bio Mater; 2022 Mar; 5(3):945-970. PubMed ID: 35170319
[TBL] [Abstract][Full Text] [Related]
7. Calibration algorithms for continuous glucose monitoring systems based on interstitial fluid sensing.
Sun T; Liu J; Chen CJ
Biosens Bioelectron; 2024 Sep; 260():116450. PubMed ID: 38843770
[TBL] [Abstract][Full Text] [Related]
8. Minimally invasive electrochemical continuous glucose monitoring sensors: Recent progress and perspective.
Zou Y; Chu Z; Guo J; Liu S; Ma X; Guo J
Biosens Bioelectron; 2023 Apr; 225():115103. PubMed ID: 36724658
[TBL] [Abstract][Full Text] [Related]
9. Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives.
Acciaroli G; Vettoretti M; Facchinetti A; Sparacino G
Biosensors (Basel); 2018 Mar; 8(1):. PubMed ID: 29534053
[TBL] [Abstract][Full Text] [Related]
10. Pushing OECTs toward Wearable: Development of a Miniaturized Analytical Control Unit for Wireless Device Characterization.
Tian X; Liu D; Bai J; Chan KS; Ip LC; Chan PKL; Zhang S
Anal Chem; 2022 Apr; 94(16):6156-6162. PubMed ID: 35385255
[TBL] [Abstract][Full Text] [Related]
11. Functionalized Organic Thin Film Transistors for Biosensing.
Wang N; Yang A; Fu Y; Li Y; Yan F
Acc Chem Res; 2019 Feb; 52(2):277-287. PubMed ID: 30620566
[TBL] [Abstract][Full Text] [Related]
12. An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids.
Yang Y; Sheng C; Dong F; Liu S
Biosens Bioelectron; 2024 Jul; 256():116280. PubMed ID: 38603840
[TBL] [Abstract][Full Text] [Related]
13. Wearable filamentary continuous sensor for interstitial glucose detection in diabetes management.
Zhang C; Luo X; Yang L; Cui Y
Anal Chim Acta; 2024 Feb; 1290():342169. PubMed ID: 38246737
[TBL] [Abstract][Full Text] [Related]
14. Microneedle-Based Glucose Sensor Platform: From
Ju J; Li L; Regmi S; Zhang X; Tang S
Biosensors (Basel); 2022 Aug; 12(8):. PubMed ID: 36005002
[TBL] [Abstract][Full Text] [Related]
15. Breathable and Stretchable Organic Electrochemical Transistors with Laminated Porous Structures for Glucose Sensing.
Guo H; Liu C; Peng Y; Gao L; Yu J
Sensors (Basel); 2023 Aug; 23(15):. PubMed ID: 37571694
[TBL] [Abstract][Full Text] [Related]
16. Continuous glucose monitoring systems - Current status and future perspectives of the flagship technologies in biosensor research.
Lee I; Probst D; Klonoff D; Sode K
Biosens Bioelectron; 2021 Jun; 181():113054. PubMed ID: 33775474
[TBL] [Abstract][Full Text] [Related]
17. A self-powered and supercapacitive microneedle continuous glucose monitoring system with a wide range of glucose detection capabilities.
Kil HJ; Kim JH; Lee K; Kang TU; Yoo JH; Lee YH; Park JW
Biosens Bioelectron; 2024 Aug; 257():116297. PubMed ID: 38677020
[TBL] [Abstract][Full Text] [Related]
18. Clinic-on-a-Needle Array toward Future Minimally Invasive Wearable Artificial Pancreas Applications.
Heifler O; Borberg E; Harpak N; Zverzhinetsky M; Krivitsky V; Gabriel I; Fourman V; Sherman D; Patolsky F
ACS Nano; 2021 Jul; 15(7):12019-12033. PubMed ID: 34157222
[TBL] [Abstract][Full Text] [Related]
19. Fluorescent-based biodegradable microneedle sensor array for tether-free continuous glucose monitoring with smartphone application.
Sang M; Cho M; Lim S; Min IS; Han Y; Lee C; Shin J; Yoon K; Yeo WH; Lee T; Won SM; Jung Y; Heo YJ; Yu KJ
Sci Adv; 2023 Jun; 9(22):eadh1765. PubMed ID: 37256939
[TBL] [Abstract][Full Text] [Related]
20. Integrated electronic/fluidic microneedle system for glucose sensing and insulin delivery.
Huang X; Liang B; Huang S; Liu Z; Yao C; Yang J; Zheng S; Wu F; Yue W; Wang J; Chen H; Xie X
Theranostics; 2024; 14(4):1662-1682. PubMed ID: 38389830
[No Abstract] [Full Text] [Related]
[Next] [New Search]