BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 38644780)

  • 21. Comparison of the new self-contained darkroom refractive screener versus table-top autorefractor and cycloplegia retinoscopy in detecting refractive error.
    Wei X; Li L; Jiang L; Lu H; Huang H; Zhong D; Pan L; Wei D; Han Y; Lin H; Chen Q
    BMC Ophthalmol; 2023 Nov; 23(1):487. PubMed ID: 38012552
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A comparison of the Plusoptix S09 with an autorefractometer of noncycloplegics and cycloplegics in children.
    Won JY; Shin HY; Kim SY; Lee YC
    Medicine (Baltimore); 2016 Aug; 95(35):e4596. PubMed ID: 27583875
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of the Spot Vision Screener for children with limited access to ocular health care.
    Barugel R; Touhami S; Samama S; Landre C; Busquet G; Vera L; Bui Quoc E
    J AAPOS; 2019 Jun; 23(3):153.e1-153.e5. PubMed ID: 31028870
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Difference of refraction values between standard autorefractometry and Plusoptix.
    Bogdănici CM; Săndulache CM; Vasiliu R; Obadă O
    Rom J Ophthalmol; 2016; 60(4):249-254. PubMed ID: 29450357
    [No Abstract]   [Full Text] [Related]  

  • 25. Screening for refractive errors in children: the plusoptiX S08 and the Retinomax K-plus2 performed by a lay screener compared to cycloplegic retinoscopy.
    Paff T; Oudesluys-Murphy AM; Wolterbeek R; Swart-van den Berg M; de Nie JM; Tijssen E; Schalij-Delfos NE
    J AAPOS; 2010 Dec; 14(6):478-83. PubMed ID: 21168070
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Intra- and inter- examiner repeatability of cycloplegic retinoscopy among young children.
    McCullough SJ; Doyle L; Saunders KJ
    Ophthalmic Physiol Opt; 2017 Jan; 37(1):16-23. PubMed ID: 28030881
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of cycloplegia on the measurement of refractive error in Chinese children.
    Li T; Zhou X; Zhu J; Tang X; Gu X
    Clin Exp Optom; 2019 Mar; 102(2):160-165. PubMed ID: 30136309
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Anterior chamber depth and axial length affect clinical performance of Spot Vision Screener.
    Yakar K
    Arq Bras Oftalmol; 2020; 83(1):43-47. PubMed ID: 31664336
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical correlation between automated vision screening under cycloplegia and retinoscopy in young children.
    Geremias A; Garcia NP; Moreira CAS; Barboza GNC; Barboza MNC
    Arq Bras Oftalmol; 2023; 86(3):232-239. PubMed ID: 35417522
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of refractive error measures by the IRX3 aberrometer and autorefraction.
    McCullough SJ; Little JA; Breslin KM; Saunders KJ
    Optom Vis Sci; 2014 Oct; 91(10):1183-90. PubMed ID: 25192432
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Performance of a photoscreener in detecting accommodation spasm.
    Demir MS; Muhafiz E
    Clin Exp Optom; 2022 Nov; 105(8):817-821. PubMed ID: 34751084
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparison of photorefraction and retinoscopy in children.
    Erdurmus M; Yagci R; Karadag R; Durmus M
    J AAPOS; 2007 Dec; 11(6):606-11. PubMed ID: 17588794
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Repeatability of Values Measured Using the Spot Vision Screener in Healthy Children and Children with Refractive Errors.
    Satou T; Nogami T; Takahashi Y; Ito M; Niida T
    J Binocul Vis Ocul Motil; 2019; 69(2):82-86. PubMed ID: 31116670
    [No Abstract]   [Full Text] [Related]  

  • 34. Comparison of the Plusoptix A09 and Retinomax K-Plus 3 with retinoscopy in children.
    Yilmaz I; Ozkaya A; Alkin Z; Ozbengi S; Yazici AT; Demirok A
    J Pediatr Ophthalmol Strabismus; 2015; 52(1):37-42. PubMed ID: 25643369
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of photorefraction by Plusoptix A12 and cycloplegic autorefraction in children.
    Ghadimi H; Nikdel M; Suh DW
    BMC Ophthalmol; 2024 Apr; 24(1):179. PubMed ID: 38641836
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical comparison of the Welch Allyn SureSight handheld autorefractor versus cycloplegic autorefraction and retinoscopic refraction.
    Iuorno JD; Grant WD; Noël LP
    J AAPOS; 2004 Apr; 8(2):123-7. PubMed ID: 15088044
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Prospective Evaluation of Photoscreeners in the Pseudophakic Eyes of Children.
    Trivedi RH; Wilson ME; Peterseim MM; Papa C; Husain M
    J Pediatr Ophthalmol Strabismus; 2016 May; 53(3):146-9. PubMed ID: 27224948
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Measurement Accuracy When Using Spot Vision Screener With or Without Cycloplegia in Young Adults.
    Tatara S; Maeda F; Ubukata H; Shiga Y; Yaoeda K
    Clin Ophthalmol; 2023; 17():3543-3548. PubMed ID: 38026593
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A Comparison of Three Different Photoscreeners in Children.
    Teberik K; Eski MT; Kaya M; Ankarali H
    J Pediatr Ophthalmol Strabismus; 2018 Sep; 55(5):306-311. PubMed ID: 29809264
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparing School-Aged Refraction Measurements Using the 2WIN-S Portable Refractor in Relation to Cycloplegic Retinoscopy: A Cross-Sectional Study.
    Liu Z; Pazo EE; Ye H; Yu C; Xu L; He W
    J Ophthalmol; 2021; 2021():6612476. PubMed ID: 34094595
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.