BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 38648663)

  • 1. Tacrolimus Monitoring in Liver Transplant Recipients, Posttransplant Cholestasis: A Comparative Between 2 Commercial Immunoassays and a Liquid Chromatography-Tandem Mass Spectrometry Method.
    Parant F; Delignette MC; Charpiat B; Lacaille L; Lebosse F; Monneret G; Mohkam K; Mabrut JY; Aubrun F; Heyer L; Antonini T
    Ther Drug Monit; 2024 Apr; ():. PubMed ID: 38648663
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the interchangeability between the new fully-automated affinity chrome-mediated immunoassay (ACMIA) and the Quantitative Microsphere System (QMS) with a CE-IVD-certified LC-MS/MS assay for therapeutic drug monitoring of everolimus after solid organ transplantation.
    Ialongo C; D'alessandro A; Sapio M; Angeloni A; Porzio O
    Clin Chem Lab Med; 2023 Jan; 61(2):245-250. PubMed ID: 36330751
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of everolimus QMS immunoassay on Architect ci4100 and liquid chromatography/mass spectrometry: lack of agreement in organ-transplanted patients.
    Hoffer E; Kurnik D; Efrati E; Scherb I; Karasik M; Ring G; Bentur Y
    Ther Drug Monit; 2015 Apr; 37(2):214-9. PubMed ID: 25162218
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Therapeutic Drug Monitoring of Everolimus: Comparability of Concentrations Determined by 2 Immunoassays and a Liquid Chromatography Tandem Mass Spectrometry Method.
    Shipkova M; Rapp S; Rigo-Bonnin R; Wieland E; Peter A
    Ther Drug Monit; 2017 Apr; 39(2):102-108. PubMed ID: 28125504
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simultaneous determination of cyclosporine and tacrolimus in human whole blood by ultra-high performance liquid chromatography tandem mass spectrometry and comparison with a chemiluminescence microparticle immunoassay.
    Mei S; Wang J; Chen D; Zhu L; Zhao M; Tian X; Hu X; Zhao Z
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Jun; 1087-1088():36-42. PubMed ID: 29704799
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of UHPLC-MS/MS method for simultaneous determination of tacrolimus and sirolimus in human whole blood and comparisons with two immunoassays.
    Liu B; Geng N; Zhao H; Tao Y; Hu L; Huang L; Feng Y
    Biomed Chromatogr; 2023 Feb; 37(2):e5538. PubMed ID: 36271903
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low plasma concentrations of albumin influence the affinity column-mediated immunoassay method for the measurement of tacrolimus in blood during the early period after liver transplantation.
    Tempestilli M; Di Stasio E; Basile MR; Elisei F; Antonini M; Ettorre GM; Iappelli M; Pucillo LP
    Ther Drug Monit; 2013 Feb; 35(1):96-100. PubMed ID: 23191996
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the New Cyclosporine and Tacrolimus Automated Electrochemiluminescence Immunoassays under Field Conditions.
    Toole B; Gechtman C; Dreier J; Kuhn J; Gutierrez MR; Barrett A; Niederau C
    Clin Lab; 2015; 61(9):1303-15. PubMed ID: 26554251
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the New Siemens Tacrolimus Assay on the Dimension EXL Integrated Chemistry System Analyzer: Comparison With an Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method.
    Bargnoux AS; Sutra T; Badiou S; Kuster N; Dupuy AM; Mourad G; Pageaux GP; Le Quintrec M; Cristol JP
    Ther Drug Monit; 2016 Dec; 38(6):808-812. PubMed ID: 27494947
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of 4 Commercial Immunoassays Used in Measuring the Concentration of Tacrolimus in Blood and Their Cross-Reactivity to Its Metabolites.
    Shigematsu T; Suetsugu K; Yamamoto N; Tsuchiya Y; Masuda S
    Ther Drug Monit; 2020 Jun; 42(3):400-406. PubMed ID: 31568181
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of tacrolimus in human whole blood in kidney transplant recipients using a rapid and specific LC-MS/MS method.
    Hieu TB; Dung NM; Toan PQ; Kien TQ; Van Duc N; Thang LV; Van Tran P; Hop VQ; Phuong NM; Ben NH; Van Khoi N; Nghia TT; Dung VD; Van Thinh N; Hang DTT; Van Men C; Long DD; Su HX
    J Clin Lab Anal; 2023 Aug; 37(15-16):e24958. PubMed ID: 37621139
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-Term Performance of Laboratory-Developed Liquid Chromatography-Tandem Mass Spectrometry Tests and a Food and Drug Administration-Approved Immunoassay for the Therapeutic Drug Monitoring of Everolimus.
    Schniedewind B; Meyer EJ; Christians U
    Ther Drug Monit; 2020 Jun; 42(3):421-426. PubMed ID: 32427781
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of a Point-of-Care Testing with Enzyme-Multiplied Immunoassay Technique and Liquid Chromatography Combined With Tandem Mass Spectrometry Methods for Therapeutic Drug Monitoring of Mycophenolic Acid: A Preliminary Study.
    Zhou H; Xiang H; Cai J; Wang Y; Zhang M; Han Y; Zhang Y
    Ther Drug Monit; 2021 Oct; 43(5):630-636. PubMed ID: 33394991
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of QMS everolimus assay using Indiko analyzer: comparison with an ultra-performance liquid chromatography-tandem mass spectrometry method.
    Buthiau D; Bargnoux AS; Badiou S; Sutra T; Dupuy AM; Pageaux GP; Mourad G; Cristol JP
    Ther Drug Monit; 2015 Apr; 37(2):275-8. PubMed ID: 25254414
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Estimating testosterone concentrations in adolescent girls: Comparison of two direct immunoassays to liquid chromatography-tandem mass spectrometry.
    McCartney CR; Burt Solorzano CM; Patrie JT; Marshall JC; Haisenleder DJ
    Steroids; 2018 Dec; 140():62-69. PubMed ID: 30217784
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cloned enzyme donor immunoassay tacrolimus assay compared with high-performance liquid chromatography-tandem mass spectrometry and microparticle enzyme immunoassay in liver and renal transplant recipients.
    Westley IS; Taylor PJ; Salm P; Morris RG
    Ther Drug Monit; 2007 Oct; 29(5):584-91. PubMed ID: 17898648
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of Six Automated Immunoassays With Isotope-Diluted Liquid Chromatography-Tandem Mass Spectrometry for Total Thyroxine Measurement.
    Yu S; Zhou W; Cheng X; Meng Q; Li H; Hou L; Lu J; Xie S; Cheng Q; Zhang C; Qiu L
    Ann Lab Med; 2019 Jul; 39(4):381-387. PubMed ID: 30809984
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical evaluation of the QMS® Tacrolimus immunoassay.
    Leung EK; Yi X; Gloria C; Yeo KT
    Clin Chim Acta; 2014 Apr; 431():270-5. PubMed ID: 24518359
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modified pentamer formation assay for measurement of tacrolimus and its active metabolites: comparison with liquid chromatography-tandem mass spectrometry and microparticle enzyme-linked immunoassay (MEIA-II).
    Armstrong VW; Schuetz E; Zhang Q; Groothuisen S; Scholz C; Shipkova M; Aboleneen H; Oellerich M
    Clin Chem; 1998 Dec; 44(12):2516-23. PubMed ID: 9836720
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry.
    Kocak FE; Ozturk B; Isiklar OO; Genc O; Unlu A; Altuntas I
    Biochem Med (Zagreb); 2015; 25(3):430-8. PubMed ID: 26526462
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.