  • 21. Validation of the watch-type HUAWEI WATCH D oscillometric wrist blood pressure monitor in adult Chinese.
    Zhang W; Zhou YN; Zhou Y; Wang JG
    Blood Press Monit; 2022 Oct; 27(5):353-356. PubMed ID: 35687029
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Validation of the Withings BPM Core Device for Self-Blood Pressure Measurements in General Population According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Hakobyan Z; Zelveian P; Topouchian J; Hazarapetyan L; Asmar R
    Vasc Health Risk Manag; 2023; 19():391-398. PubMed ID: 37426327
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Validation of the JAMR F1701T (arm type) pressure monitor according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/ISO 81060-2:2018 protocol.
    Li J; Han LH; Feng R; Wu LH; Cai J; Zeng TY; Liu H; Zeng YW; Zhou L; Zhan ZQ
    Blood Press Monit; 2023 Jun; 28(3):163-166. PubMed ID: 37016972
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Validation of the iHealth ambulatory blood pressure monitor in adults according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization standard.
    Kollias A; Ntineri A; Kyriakoulis KG; Stambolliu E; Stergiou GS
    Blood Press Monit; 2018 Apr; 23(2):115-116. PubMed ID: 29406327
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.
    Stergiou GS; Asmar R; Myers M; Palatini P; Parati G; Shennan A; Wang J; O'Brien E;
    J Hypertens; 2018 Mar; 36(3):479-487. PubMed ID: 29384984
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Validation of the AViTA BPM636 upper arm blood pressure monitor in adults and pregnant women according to the ANSI/AAMI/ISO 81060-2:2013.
    Lee CN; Wu CK; Huang IC
    Blood Press Monit; 2023 Aug; 28(4):215-220. PubMed ID: 37074406
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.
    Huang JF; Zhang W; Li Y; Wang JG
    Blood Press Monit; 2019 Dec; 24(6):315-318. PubMed ID: 31577550
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.
    Stergiou GS; Alpert B; Mieke S; Asmar R; Atkins N; Eckert S; Frick G; Friedman B; Graßl T; Ichikawa T; Ioannidis JP; Lacy P; McManus R; Murray A; Myers M; Palatini P; Parati G; Quinn D; Sarkis J; Shennan A; Usuda T; Wang J; Wu CO; O'Brien E
    Hypertension; 2018 Mar; 71(3):368-374. PubMed ID: 29386350
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Validation of the Wellvii VitalDetect blood pressure monitor in general population according to the International Standardization Organization 81060-2:2018.
    Li LY; Chen JF; Bing S; Liu K; Cheng R; Wan Y
    Blood Press Monit; 2024 Apr; 29(2):93-98. PubMed ID: 37997441
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Validation of Omron HEM-7600T, a wearable device for monitoring blood pressure, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol in the general population without arrhythmias.
    Takahashi H; Saito K; Hishiki Y
    Blood Press Monit; 2021 Apr; 26(2):156-159. PubMed ID: 33577185
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Validation of the iHealth Track upper-arm blood pressure monitor KN-550BT in general population according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018+AMD1:2020).
    Shi L; Zhang XY; Sun JY; Chen JF; Ma YF; Zhou KY
    Blood Press Monit; 2024 Feb; 29(1):41-44. PubMed ID: 37702596
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension.
    Omboni S; Riva I; Giglio A; Caldara G; Groppelli A; Parati G
    Blood Press Monit; 2007 Aug; 12(4):233-42. PubMed ID: 17625396
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Smartphone based blood pressure measurement: accuracy of the OptiBP mobile application according to the AAMI/ESH/ISO universal validation protocol.
    Degott J; Ghajarzadeh-Wurzner A; Hofmann G; Proença M; Bonnier G; Lemkaddem A; Lemay M; Christen U; Knebel JF; Durgnat V; Burnier M; Wuerzner G; Schoettker P
    Blood Press Monit; 2021 Dec; 26(6):441-448. PubMed ID: 34139747
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Validation of the G.LAB MD2231 digital automatic wrist blood pressure monitor according to multiple protocols.
    Jiao Y; Guan Q; Wu L; Wang C; Cao L
    Blood Press Monit; 2017 Aug; 22(4):226-229. PubMed ID: 28328581
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Simultaneous validation of the SunTech CT40 automated blood pressure measurement device by the 1993 British Hypertension Society protocol and the Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2: 2013 standard.
    Polo Friz H; Punzi V; Petri F; Orlandi R; Maggiolini D; Polo Friz M; Primitz L; Vighi G
    Blood Press Monit; 2017 Oct; 22(5):298-301. PubMed ID: 28763332
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Validation of the FM-800 ambulatory blood pressure monitor according to the Association for the Advancement of Medical Instrumentation criteria and the International Protocol.
    Nakamura K; Kikuya M; Hara A; Hirose T; Obara T; Metoki H; Asayama K; Inoue R; Ohkubo T; Totsune K; Imai Y
    Clin Exp Hypertens; 2010; 32(8):523-7. PubMed ID: 21091358
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Validation of Omron HEM-9200T, a home blood pressure monitoring device for the upper arm, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol.
    Takahashi H; Saito K; Yakura N
    J Hum Hypertens; 2022 Apr; 36(4):416-419. PubMed ID: 33837291
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Validation of the ANDON KD-595 automated upper-arm blood pressure monitor according to the universal standard.
    Liu K; Wu D; Bing S; Li LY
    Blood Press Monit; 2024 Apr; 29(2):103-106. PubMed ID: 38193382
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of Meditech ABPM-06 ambulatory blood pressure measuring device, according to the European Society of Hypertension, the British Hypertension Society and the International Organization for Standardization Protocol.
    Hermányi Z; Pokoly B; Visolyi G; Barna I
    Blood Press Monit; 2019 Aug; 24(4):208-211. PubMed ID: 31162148
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.
    Pini C; Pastori M; Baccheschi J; Omboni S; Parati G;
    Blood Press Monit; 2007 Jun; 12(3):179-84. PubMed ID: 17496468
    [TBL] [Abstract][Full Text] [Related]  