These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 38656714)

  • 21. Thrombosis in Extracorporeal Membrane Oxygenation (ECMO) Circuits.
    Figueroa Villalba CA; McMullan DM; Reed RC; Chandler WL
    ASAIO J; 2022 Aug; 68(8):1083-1092. PubMed ID: 34860711
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pulse oximetry in severe carbon monoxide poisoning.
    Hampson NB
    Chest; 1998 Oct; 114(4):1036-41. PubMed ID: 9792574
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Circuit oxygenator contributes to extracorporeal membrane oxygenation-induced hemolysis.
    Williams DC; Turi JL; Hornik CP; Bonadonna DK; Williford WL; Walczak RJ; Watt KM; Cheifetz IM
    ASAIO J; 2015; 61(2):190-5. PubMed ID: 25419829
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Effect of different connection schemes of continuous renal replacement therapy and extracorporeal membrane oxygenation on arterial and venous pressure: an in vitro and in vivo study].
    Wang J; Xu Q; Li J; Wang T; Zhong C; Chen Q; Fang K; Jiang H; Zhang P; Lu W; Jiang X
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2022 Apr; 34(4):388-393. PubMed ID: 35692204
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Correlation between Carboxyhemoglobin Levels Measured by Blood Gas Analysis and by Multiwave Pulse Oximetry.
    Yu J; Lee J; Cho Y; Oh J; Kang H; Lim TH; Ko BS
    J Pers Med; 2024 Jan; 14(2):. PubMed ID: 38392600
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Establishment and evaluation of a rat model of extracorporeal membrane oxygenation (ECMO) thrombosis using a 3D-printed mock-oxygenator.
    Umei N; Lai A; Miller J; Shin S; Roberts K; Ai Qatarneh S; Ichiba S; Sakamoto A; Cook KE
    J Transl Med; 2021 Apr; 19(1):179. PubMed ID: 33910585
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Clinical Factors Influencing Endogenous Carbon Monoxide Production and Carboxyhemoglobin Levels in Neonates.
    Lozar Krivec J; Lozar Manfreda K; Paro-Panjan D
    J Pediatr Hematol Oncol; 2022 Jan; 44(1):e84-e90. PubMed ID: 33735151
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Novel application of indocyanine green fluorescence imaging for real-time detection of thrombus in a membrane oxygenator.
    Sakurai H; Fujiwara T; Ohuchi K; Hijikata W; Inoue Y; Seki H; Tahara T; Yokota S; Ogata A; Mizuno T; Arai H
    Artif Organs; 2021 Oct; 45(10):1173-1182. PubMed ID: 34037247
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Non-invasive monitoring of carboxyhemoglobin during hyperbaric oxygen therapy.
    Bidstrup D; Ravn F; Smidt-Nielsen IG; Wahl AM; Jansen EC; Hyldegaard O
    Undersea Hyperb Med; 2021; 48(1):33-42. PubMed ID: 33648031
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The Hematological Effects of Extracorporeal Membrane Oxygenator Exchange.
    Hoffman KR; Diehl A; Paul E; Burrell AJC
    ASAIO J; 2023 Jul; 69(7):e308-e314. PubMed ID: 37146593
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of anticoagulation strategies for veno-venous ECMO support in acute respiratory failure.
    Seeliger B; Döbler M; Friedrich R; Stahl K; Kühn C; Bauersachs J; Steinhagen F; Ehrentraut SF; Schewe JC; Putensen C; Welte T; Hoeper MM; Tiede A; David S; Bode C
    Crit Care; 2021 Jan; 24(1):701. PubMed ID: 33397427
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Predictors of Oxygenator Exchange in Patients Receiving Extracorporeal Membrane Oxygenation.
    Basken R; Cosgrove R; Malo J; Romero A; Patanwala A; Finger J; Kazui T; Khalpey Z; Mosier J
    J Extra Corpor Technol; 2019 Jun; 51(2):61-66. PubMed ID: 31239577
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effect of Platelet Transfusions on Extracorporeal Life Support Oxygenator's Function.
    Chegondi M; Vijayakumar N; Badheka A; Karam O
    Front Pediatr; 2022; 10():826477. PubMed ID: 35321010
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The pulse oximetry gap in carbon monoxide intoxication.
    Buckley RG; Aks SE; Eshom JL; Rydman R; Schaider J; Shayne P
    Ann Emerg Med; 1994 Aug; 24(2):252-5. PubMed ID: 8037391
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Relationship between venous and arterial carboxyhemoglobin levels in patients with suspected carbon monoxide poisoning.
    Touger M; Gallagher EJ; Tyrell J
    Ann Emerg Med; 1995 Apr; 25(4):481-3. PubMed ID: 7710152
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of Pulsatile Blood Flow on Oxygenator Performance.
    Schraven L; Kaesler A; Flege C; Kopp R; Schmitz-Rode T; Steinseifer U; Arens J
    Artif Organs; 2018 Apr; 42(4):410-419. PubMed ID: 29436001
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improving ECMO therapy: Monitoring oxygenator functionality and identifying key indicators, factors, and considerations for changeout.
    Butt SP; Razzaq N; Saleem Y; Cook B; Abdulaziz S
    J Extra Corpor Technol; 2024 Mar; 56(1):20-29. PubMed ID: 38488715
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Modification strategies to improve the membrane hemocompatibility in extracorporeal membrane oxygenator (ECMO).
    He T; He J; Wang Z; Cui Z
    Adv Compos Hybrid Mater; 2021; 4(4):847-864. PubMed ID: 33969267
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Carboxyhemoglobin measurement by hospitals: implications for the diagnosis of carbon monoxide poisoning.
    Hampson NB; Scott KL; Zmaeff JL
    J Emerg Med; 2006 Jul; 31(1):13-6. PubMed ID: 16798147
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Circuit change during extracorporeal membrane oxygenation: single-center retrospective study of 48 changes.
    Genty T; Burguburu S; Imbert A; Roman C; Camille W; Thès J; Stéphan F
    Crit Care; 2023 Jun; 27(1):219. PubMed ID: 37269022
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.