These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 38685354)

  • 1. Finite Element Analysis of Different Carbon Fiber Reinforced Polyetheretherketone Dental Implants in Implant-supported Fixed Denture.
    Zhou Z; Shi R; Wang J; Han X; Gao W; Jiao J; Qi Y; Li Y; Zhou Y; Zhao J
    J Stomatol Oral Maxillofac Surg; 2024 Apr; ():101902. PubMed ID: 38685354
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative analysis of stress distribution around CFR‑PEEK implants and titanium implants with different prosthetic crowns: A finite element analysis.
    Tamrakar SK; Mishra SK; Chowdhary R; Rao S
    Dent Med Probl; 2021; 58(3):359-367. PubMed ID: 34597479
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical behavior of carbon fiber-reinforced polyetheretherketone as a dental implant material in implant-supported overdenture under mandibular trauma: A finite element analysis study.
    Bilginaylar K; Ayali A
    Niger J Clin Pract; 2023 Oct; 26(10):1538-1546. PubMed ID: 37929532
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Carbon fiber-reinforced PEEK in implant dentistry: A scoping review on the finite element method.
    Souza JCM; Pinho SS; Braz MP; Silva FS; Henriques B
    Comput Methods Biomech Biomed Engin; 2021 Sep; 24(12):1355-1367. PubMed ID: 33616450
    [No Abstract]   [Full Text] [Related]  

  • 5. Evaluation of stress and deformation in bone with titanium, CFR-PEEK and zirconia ceramic implants by finite element analysis.
    Mahalakshmi G; Gasthi A; Hosain Almansour HM; Babaji P; Madhusudhana Rao U; Haseeb SA; Venkata Ramaiah V
    Dent Res J (Isfahan); 2023; 20():57. PubMed ID: 37388306
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fabrication and mechanical properties of different types of carbon fiber reinforced polyetheretherketone: A comparative study.
    Zhou Z; Han X; Gao W; Li Y; Yu W; Yang S; Zhang J; Wang J; Shi R; Zhou Y; Zhao J
    J Mech Behav Biomed Mater; 2022 Nov; 135():105472. PubMed ID: 36162163
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical Effects of Titanium and Carbon Fiber Reinforced PEEK as Dental Implant Material: A Finite Element Analysis.
    Ediboğlu E; Akdeniz SS; Beyler E
    Int J Oral Maxillofac Implants; 2024 Jun; 0(0):1-17. PubMed ID: 38941169
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants.
    Haseeb SA; K C V; Vijaykumar N; Sree Durga B A; Kumar AS; M K S
    Natl J Maxillofac Surg; 2022; 13(2):243-247. PubMed ID: 36051812
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone.
    Neumann EA; Villar CC; França FM
    Braz Oral Res; 2014; 28():. PubMed ID: 25098826
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Three-dimensional finite element analysis of different framework materials in implant-supported fixed mandibular prosthesis].
    Yu WQ; Li XQ; Chen SY; Ma XN; Xu X
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2021 Feb; 56(2):190-195. PubMed ID: 33557504
    [No Abstract]   [Full Text] [Related]  

  • 11. Stress distribution around different abutments on titanium and CFR-PEEK implant with different prosthetic crowns under parafunctional loading: A 3D FEA study.
    Mourya A; Nahar R; Mishra SK; Chowdhary R
    J Oral Biol Craniofac Res; 2021; 11(2):313-320. PubMed ID: 33816100
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical analyses of one-piece dental implants composed of titanium, zirconia, PEEK, CFR-PEEK, or GFR-PEEK: Stresses, strains, and bone remodeling prediction by the finite element method.
    Fabris D; Moura JPA; Fredel MC; Souza JCM; Silva FS; Henriques B
    J Biomed Mater Res B Appl Biomater; 2022 Jan; 110(1):79-88. PubMed ID: 34173713
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis.
    Deste Gökay G; Oyar P; Gökçimen G; Durkan R
    BMC Oral Health; 2024 May; 24(1):545. PubMed ID: 38730391
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Finite element analysis to assess stress and deformation in bone with glass fiber-reinforced-poly-ether-ether-ketone, zirconia, and titanium implants.
    Haseeb SA; Kumar AS; Chaitra MP; Vinaya KC; Gudal SS; Rahmam FP; Babaji P
    Tzu Chi Med J; 2023; 35(3):231-236. PubMed ID: 37545794
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of Implant Location on Fiber-Reinforced Maxillary Overdentures with Finite Element Method.
    Güzelce ES; Tokar E; Karacer Ö
    Int J Oral Maxillofac Implants; 2023 May, Jun; 38(3):523-532. PubMed ID: 37279217
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Finite element analysis of the biomechanical effects of titanium and Cfr-peek additively manufactured subperiosteal jaw implant (AMSJI) on maxilla.
    Altıparmak N; Polat S; Onat S
    J Stomatol Oral Maxillofac Surg; 2023 Feb; 124(1S):101290. PubMed ID: 36152972
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of stress/strain in dental implants and abutments of alternative materials compared to conventional titanium alloy-3D non-linear finite element analysis.
    Tretto PHW; Dos Santos MBF; Spazzin AO; Pereira GKR; Bacchi A
    Comput Methods Biomech Biomed Engin; 2020 Jun; 23(8):372-383. PubMed ID: 32116034
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Exploring the bio-mechanical behavior of PEEK and CFR-PEEK materials for dental implant applications using finite element analysis.
    Reddy KUK; Seth A; Vuppuluri A; Verma PC; Narala SKR; Babu PJ; Saravanan P
    J Prosthodont Res; 2024 May; ():. PubMed ID: 38777753
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of carbon-fiber-reinforced polyetheretherketone on stress distribution in a redesigned tumor-type knee prosthesis: a finite element analysis.
    Wu H; Guo Y; Guo W
    Front Bioeng Biotechnol; 2023; 11():1243936. PubMed ID: 37823023
    [No Abstract]   [Full Text] [Related]  

  • 20. Stress distribution in bone around an implant-supported three-unit fixed dental prosthesis using two different computer-aided designing/computer-aided milling provisional crown materials: Milled polymethylmethacrylate and milled polyetheretherketone - A finite element analysis.
    Barua SL; Poduval TS; Rani S; Jain N; Thakur S
    Dent Res J (Isfahan); 2023; 20():33. PubMed ID: 37180686
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.