116 related articles for article (PubMed ID: 38688871)
1. Seegene Anyplex II assays detect HPV consistently using DNA extracts from different extraction methods.
Balgovind P; Murray G; Machalek DA; Garland SM; Azzato F; Hinaut JA; Danielewski J; Molano M; Haqshenas G
Lett Appl Microbiol; 2024 May; 77(5):. PubMed ID: 38688871
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of the Roche MagNA Pure 96 nucleic acid extraction platform for the Seegene Anyplex II HPV28 detection assay.
Atchison S; Shilling H; Balgovind P; Machalek DA; Hawkes D; Garland SM; Saville M; Murray G; Molano M; Danielewski J; Phillips S
J Appl Microbiol; 2021 Nov; 131(5):2592-2599. PubMed ID: 33942451
[TBL] [Abstract][Full Text] [Related]
3. HPV genotype-specific concordance between EuroArray HPV, Anyplex II HPV28 and Linear Array HPV Genotyping test in Australian cervical samples.
Cornall AM; Poljak M; Garland SM; Phillips S; Machalek DA; Tan JH; Quinn MA; Tabrizi SN
Papillomavirus Res; 2017 Dec; 4():79-84. PubMed ID: 29179874
[TBL] [Abstract][Full Text] [Related]
4. Comparison between the Roche Cobas 4800 Human Papillomavirus (HPV), Abbott RealTime High-Risk HPV, Seegene Anyplex II HPV28, and Novel Seegene Allplex HPV28 Assays for High-Risk HPV Detection and Genotyping in Mocked Self-Samples.
Bell M; Verberckmoes B; Devolder J; Vermandere H; Degomme O; Guimarães YM; Godoy LR; Ambrosino E; Cools P; Padalko E
Microbiol Spectr; 2023 Aug; 11(4):e0008123. PubMed ID: 37284753
[TBL] [Abstract][Full Text] [Related]
5. Clinical performance of Anyplex II HPV28 by human papillomavirus type and viral load in a referral population.
Baasland I; Romundstad PR; Eide ML; Jonassen CM
PLoS One; 2019; 14(1):e0210997. PubMed ID: 30673759
[TBL] [Abstract][Full Text] [Related]
6. Comparative evaluation of HPV genotyping: A study on the performance concordance between Anyplex II HPV28 detection and Linear Array genotyping tests in nationwide studies in Brazil.
Bandeira IC; Comerlato J; Bessel M; Fernandes BV; Mota G; Villa LL; de Souza FMA; Pereira GFM; Wendland EM
PLoS One; 2024; 19(6):e0305122. PubMed ID: 38861542
[TBL] [Abstract][Full Text] [Related]
7. Comparative evaluation of Anyplex II HPV28 and Allplex HPV28 molecular assays for human papillomavirus detection and genotyping in anogenital cancer screening.
Naegele K; Bubendorf L; Hirsch HH; Leuzinger K
J Med Virol; 2024 Jun; 96(6):e29649. PubMed ID: 38812416
[TBL] [Abstract][Full Text] [Related]
8. Interest of cytology combined with Xpert
Nassereddine H; Charpentier C; Bucau M; Joly V; Bienvenu L; Davitian C; Abramowitz L; Benabderrahmane D; Kotelevets L; Chastre E; Lehy T; Walker F
HIV Med; 2018 Nov; 19(10):698-707. PubMed ID: 30062761
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of Seegene Anyplex II Performance for Detection of Human Papillomavirus Genotypes in Formalin-Fixed, Paraffin-Embedded Cervical Cancer Specimens.
Haqshenas G; Molano M; Phillips S; Balgovind P; Garland SM; Hawkes D; Brotherton JM; Machalek DA; Murray G
Arch Pathol Lab Med; 2024 Mar; 148(3):353-358. PubMed ID: 37226838
[TBL] [Abstract][Full Text] [Related]
10. Anyplex II HPV28 detection and Anyplex II HPV HR detection assays are highly concordant with other commercial assays for detection of high-risk HPV genotypes in women with high grade cervical abnormalities.
Cornall AM; Poljak M; Garland SM; Phillips S; Tan JH; Machalek DA; Quinn MA; Tabrizi SN
Eur J Clin Microbiol Infect Dis; 2017 Mar; 36(3):545-551. PubMed ID: 27822653
[TBL] [Abstract][Full Text] [Related]
11. Comparison of the Anyplex II HPV28 assay with the Hybrid Capture 2 assay for the detection of HPV infection.
Kwon MJ; Roh KH; Park H; Woo HY
J Clin Virol; 2014 Apr; 59(4):246-9. PubMed ID: 24568964
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the SPF10-INNO LiPA human papillomavirus (HPV) genotyping test and the roche linear array HPV genotyping test.
van Hamont D; van Ham MA; Bakkers JM; Massuger LF; Melchers WJ
J Clin Microbiol; 2006 Sep; 44(9):3122-9. PubMed ID: 16954236
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the Roche MagNA Pure 96 nucleic acid extraction platform for the SPF10 line probe assay system.
Peng S; Yin J; Liu Y; Bi Z; Wu T; Qiao Y
J Appl Microbiol; 2023 Aug; 134(8):. PubMed ID: 37442630
[TBL] [Abstract][Full Text] [Related]
14. Analytical evaluation of the PapilloCheck test, a new commercial DNA chip for detection and genotyping of human papillomavirus.
Dalstein V; Merlin S; Bali C; Saunier M; Dachez R; Ronsin C
J Virol Methods; 2009 Mar; 156(1-2):77-83. PubMed ID: 19041893
[TBL] [Abstract][Full Text] [Related]
15. Enhanced detection and typing of human papillomavirus (HPV) DNA in anogenital samples with PGMY primers and the Linear array HPV genotyping test.
Coutlée F; Rouleau D; Petignat P; Ghattas G; Kornegay JR; Schlag P; Boyle S; Hankins C; Vézina S; Coté P; Macleod J; Voyer H; Forest P; Walmsley S; ; Franco E
J Clin Microbiol; 2006 Jun; 44(6):1998-2006. PubMed ID: 16757590
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of the Anyplex II HPV28 Assay in the Detection of Human Papillomavirus in Archival Samples of Oropharyngeal Carcinomas.
Rollo F; Donà MG; Pichi B; Pellini R; Covello R; Benevolo M
Arch Pathol Lab Med; 2020 May; 144(5):620-625. PubMed ID: 31509455
[TBL] [Abstract][Full Text] [Related]
17. Comparison of Seegene Anyplex II HPV28 with the PGMY-CHUV assay for human papillomavirus genotyping.
Estrade C; Sahli R
J Clin Microbiol; 2014 Feb; 52(2):607-12. PubMed ID: 24478495
[TBL] [Abstract][Full Text] [Related]
18. Comparison of the analytical and clinical performance of five tests for the detection of human papillomavirus genital infection.
Del Pino M; Alonso I; Rodriguez-Trujillo A; Bernal S; Geraets D; Guimerà N; Torne A; Ordi J
J Virol Methods; 2017 Oct; 248():238-243. PubMed ID: 28739302
[TBL] [Abstract][Full Text] [Related]
19. Human papillomavirus oncogene mRNA testing for the detection of anal dysplasia in HIV-positive men who have sex with men.
Silling S; Kreuter A; Hellmich M; Swoboda J; Pfister H; Wieland U
J Clin Virol; 2012 Apr; 53(4):325-31. PubMed ID: 22261122
[TBL] [Abstract][Full Text] [Related]
20. Comparison of real-time multiplex human papillomavirus (HPV) PCR assays with the linear array HPV genotyping PCR assay and influence of DNA extraction method on HPV detection.
Roberts CC; Swoyer R; Bryan JT; Taddeo FJ
J Clin Microbiol; 2011 May; 49(5):1899-906. PubMed ID: 21346041
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]