132 related articles for article (PubMed ID: 38691222)
1. Maximum resistance pressure at the time of lung tissue rupture after porcine lung transection using automatic linear staplers with different reinforcement methods.
Takamori S; Takenaka T; Shimokawa M; Hashinokuchi A; Matsudo K; Nagano T; Kohno M; Miura N; Yoshizumi T
Surg Today; 2024 May; ():. PubMed ID: 38691222
[TBL] [Abstract][Full Text] [Related]
2. [A device to prevent an air-leakage after a thoracoscopic surgery for spontaneous pneumothorax].
Minami K; Saito Y; Shomura Y; Imamura H
Kyobu Geka; 2003 Oct; 56(11):904-7. PubMed ID: 14579690
[TBL] [Abstract][Full Text] [Related]
3. Reduction of air leakage using linear staple device with bioabsorbable polyglycolic acid felt for pulmonary lobectomy.
Deguchi H; Tomoyasu M; Shigeeda W; Kaneko Y; Kanno H; Saito H
Gen Thorac Cardiovasc Surg; 2020 Mar; 68(3):266-272. PubMed ID: 31541348
[TBL] [Abstract][Full Text] [Related]
4. Efficacy of oxidized regenerated cellulose combined with fibrin glue in reducing pulmonary air leakage after segmentectomy in a porcine lung model.
Yang H; Dong Z; Wang H; Liu Z; Sun W; Wang K; Xu X; Wen W; Wang J; Chen L; Zhu Q
Front Bioeng Biotechnol; 2022; 10():1052535. PubMed ID: 36545677
[No Abstract] [Full Text] [Related]
5. Effect of cutting technique at the intersegmental plane during segmentectomy on expansion of the preserved segment: comparison between staplers and scissors in ex vivo pig lung.
Asakura K; Izumi Y; Kohno M; Ohtsuka T; Okui M; Hashimoto K; Nakayama T; Nomori H
Eur J Cardiothorac Surg; 2011 Jul; 40(1):e34-8. PubMed ID: 21450477
[TBL] [Abstract][Full Text] [Related]
6. Can a stapling device with bioabsorbable polyglycolic acid felt reduce intraoperative air leak?
Makino T; Matsumura T; Kono M; Anami Y
J Thorac Dis; 2024 Feb; 16(2):893-900. PubMed ID: 38505053
[TBL] [Abstract][Full Text] [Related]
7. Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on
Suzuki T; Asakura K; Egawa T; Kawauchi M; Okubo Y; Masai K; Kaseda K; Hishida T; Asamura H
J Thorac Dis; 2022 Jun; 14(6):2045-2052. PubMed ID: 35813731
[TBL] [Abstract][Full Text] [Related]
8. Triple-layer sealing with absorptive mesh and fibrin glue is effective in preventing air leakage after segmentectomy: results from experiments and clinical study.
Nomori H; Abe M; Sugimura H; Takegawa Y; Oka S; Takeshi A
Eur J Cardiothorac Surg; 2014 May; 45(5):910-3. PubMed ID: 24157483
[TBL] [Abstract][Full Text] [Related]
9. A unique method for repairing intraoperative pulmonary air leakage with both polyglycolic acid sheets and fibrin glue.
Yano T; Haro A; Shikada Y; Okamoto T; Maruyama R; Maehara Y
World J Surg; 2012 Feb; 36(2):463-7. PubMed ID: 22089922
[TBL] [Abstract][Full Text] [Related]
10. Reduction of Pulmonary Air Leaks with a Combination of Polyglycolic Acid Sheet and Alginate Gel in Rats.
Matoba M; Takagi T; Tsujimoto H; Ozamoto Y; Ueda J; Hagiwara A
Biomed Res Int; 2018; 2018():3808675. PubMed ID: 29487867
[TBL] [Abstract][Full Text] [Related]
11. Gelatin-resorcinol-formaldehyde-glutaraldehyde glue-spread stapler prevents air leakage from the lung.
Nomori H; Horio H
Ann Thorac Surg; 1997 Feb; 63(2):352-5. PubMed ID: 9033299
[TBL] [Abstract][Full Text] [Related]
12. Staple-line reinforcement with a new type of polyglycolic acid felt.
Kawamura M; Kase K; Sawafuji M; Watanabe M; Horinouchi H; Kobayashi K
Surg Laparosc Endosc Percutan Tech; 2001 Feb; 11(1):43-6. PubMed ID: 11269555
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of different stapler line strengthening techniques with burst pressures in patients undergoing sleeve gastrectomy. An experimental study.
Akici M; Çilekar M
Ann Ital Chir; 2020; 91():201-206. PubMed ID: 32719181
[TBL] [Abstract][Full Text] [Related]
14. The utility of the Stapler with PGA sheet for pulmonary wedge resection: a propensity score-matched analysis.
Shigeeda W; Deguchi H; Tomoyasu M; Kaneko Y; Kanno H; Tanita T; Saito H
J Thorac Dis; 2019 Apr; 11(4):1546-1553. PubMed ID: 31179098
[TBL] [Abstract][Full Text] [Related]
15. Development of an effective method utilizing fibrin glue to repair pleural defects in an ex-vivo pig model.
Kondo N; Takegawa Y; Hashimoto M; Matsumoto S; Oka S; Hasegawa S
J Cardiothorac Surg; 2020 May; 15(1):110. PubMed ID: 32448399
[TBL] [Abstract][Full Text] [Related]
16. The role of new staplers in reducing the incidence of air leak.
Marra A; Yankulov A
J Thorac Dis; 2023 Feb; 15(2):893-900. PubMed ID: 36910065
[TBL] [Abstract][Full Text] [Related]
17. Utility of the powered stapler for radical pulmonary resection: a propensity score-matched analysis.
Shigeeda W; Deguchi H; Tomoyasu M; Kudo S; Kaneko Y; Kanno H; Saito H
Surg Today; 2021 Apr; 51(4):582-588. PubMed ID: 33037476
[TBL] [Abstract][Full Text] [Related]
18. Reduction of air leaks in a canine model of pulmonary resection with a new staple-line buttress.
Hashimoto A; Kuwabara M; Hirasaki Y; Tsujimoto H; Torii T; Nakamura T; Hagiwara A
J Thorac Cardiovasc Surg; 2011 Aug; 142(2):366-71. PubMed ID: 21664626
[TBL] [Abstract][Full Text] [Related]
19. The covering with forceps-assisted polymeric biodegradable sheet and endostapling method: a simplified technique for wide coverage and reinforcement of staple-line in video-assisted thoracoscopic bullectomy for spontaneous pneumothorax.
Saito T; Kaneda H; Konobu T; Saito Y
Interact Cardiovasc Thorac Surg; 2011 Feb; 12(2):103-5. PubMed ID: 21051376
[TBL] [Abstract][Full Text] [Related]
20. Prevention of postoperative air leakage from lungs using a purified human collagen membrane-polyglycolic acid sheet.
Tsuda T; Nakamura T; Yamamoto Y; Teramachi M; Kiyotani T; Lee YH; Shimizu Y
Ann Thorac Surg; 1999 Aug; 68(2):339-42. PubMed ID: 10475392
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]