132 related articles for article (PubMed ID: 38691222)
21. Assessment of a novel stapler performance for laparoscopic sleeve gastrectomy.
Salyer C; Spuzzillo A; Wakefield D; Gomaa D; Thompson J; Goodman M
Surg Endosc; 2021 Jul; 35(7):4016-4021. PubMed ID: 32749610
[TBL] [Abstract][Full Text] [Related]
22. Secure overlap stapling using a linear stapler with bioabsorbable polyglycolic acid felt.
Naito M; Sato T; Nakamura T; Yamanashi T; Miura H; Tsutsui A; Watanabe M
Asian J Endosc Surg; 2017 Aug; 10(3):308-312. PubMed ID: 28224709
[TBL] [Abstract][Full Text] [Related]
23. Medical and Economic Evaluation of FOREseal Bioabsorbable Reinforcement Sleeves Compared With Current Standard of Care for Reducing Air Leakage Duration After Lung Resection for Malignancy: A Randomized Trial.
Alifano M; Jayle C; Bertin F; Magdeleinat P; Castier Y; Tiffet O; Bernard A; Tronc F; Brichon PY; Dumont P; Grosdidier G; Dujon A; Grine A; Pereira H; Le Jeannic A; Vinet MA; MaOulida H; Durand-Zaleski I; Riquet M; Chatellier G; Regnard JF;
Ann Surg; 2017 Jan; 265(1):45-53. PubMed ID: 28009728
[TBL] [Abstract][Full Text] [Related]
24. Improving the side-to-side stapled anastomosis: comparison of staplers for robust crotch formation.
Kimura M; Kuwabara Y; Taniwaki S; Mitsui A; Shibata Y; Ueno S
Surg Obes Relat Dis; 2018 Jan; 14(1):16-21. PubMed ID: 29108894
[TBL] [Abstract][Full Text] [Related]
25. Ex vivo pneumostasis evaluation of a variable-height staple design.
Contini E; Godek ML; Whiffen JM; Bronson DG
Innovations (Phila); 2013; 8(4):284-8. PubMed ID: 24145973
[TBL] [Abstract][Full Text] [Related]
26. A combination of polyglycolic acid fabric and fibrin glue prevents air leakage from a lung defect.
Suzuki A; Konishi H; Suzuki T; Katsumata T; Hanaoka N; Nakamura K; Matsubara C; Fujii S; Nemoto S
Interact Cardiovasc Thorac Surg; 2022 Sep; 35(4):. PubMed ID: 35894665
[TBL] [Abstract][Full Text] [Related]
27. The efficacy and side effects of gelatin-resorcinol formaldehyde-glutaraldehyde (GRFG) glue for preventing and sealing pulmonary air leakage.
Nomori H; Horio H; Suemasu K
Surg Today; 2000; 30(3):244-8. PubMed ID: 10752777
[TBL] [Abstract][Full Text] [Related]
28. Air leaks: Stapling affects porcine lungs biomechanics.
Bonnet B; Tabiai I; Rakovich G; Gosselin FP; Villemure I
J Mech Behav Biomed Mater; 2022 Jan; 125():104883. PubMed ID: 34678619
[TBL] [Abstract][Full Text] [Related]
29. A clinical study of efficacy of polyglycolic acid sleeve after video-assisted thoracoscopic bullectomy for primary spontaneous pneumothorax.
Zhang D; Miao J; Hu X; Hu B; Li H
J Thorac Dis; 2017 Apr; 9(4):1093-1099. PubMed ID: 28523164
[TBL] [Abstract][Full Text] [Related]
30. Obtaining secure stapling of a double stapling anastomosis.
Nakayama S; Hasegawa S; Hida K; Kawada K; Sakai Y
J Surg Res; 2015 Feb; 193(2):652-7. PubMed ID: 25277356
[TBL] [Abstract][Full Text] [Related]
31. Efficacy of a sheet combined with fibrin glue in repair of pleural defect at the early phase after lung surgery in a canine model.
Sakai T; Matsutani N; Kanai E; Yamauchi Y; Uehara H; Iinuma H; Kawamura M
Gen Thorac Cardiovasc Surg; 2018 Feb; 66(2):103-107. PubMed ID: 29101533
[TBL] [Abstract][Full Text] [Related]
32. Comparison of Laparoscopic Sleeve Gastrectomy Bleeding and Leakage Rates in Four Staple-Line Reinforcement Methods: A Prospective Observational Study.
Di Capua F; Cesana GC; Uccelli M; Ciccarese F; Olmi S
J Laparoendosc Adv Surg Tech A; 2022 Nov; 32(11):1176-1180. PubMed ID: 35467939
[No Abstract] [Full Text] [Related]
33. Perioperative outcome of laparoscopic left lateral liver resection is improved by using staple line reinforcement technique: a case report.
Consten EC; Gagner M
J Gastrointest Surg; 2005 Mar; 9(3):360-4. PubMed ID: 15749597
[TBL] [Abstract][Full Text] [Related]
34. Powered stapling system with gripping surface technology for pulmonary resection of lung cancer: real-world clinical effectiveness.
Gan C; Zeng F; Cong W; Tang T; Feng G
Cost Eff Resour Alloc; 2022 Dec; 20(1):72. PubMed ID: 36564821
[TBL] [Abstract][Full Text] [Related]
35. Staple line reinforcement with new biomaterial increased burst strength pressure: an animal study.
Pinheiro JS; Correa JL; Cohen RV; Novaes JA; Schiavon CA
Surg Obes Relat Dis; 2006; 2(3):397-9, discussion 400. PubMed ID: 16925361
[TBL] [Abstract][Full Text] [Related]
36. Treatment of air leakage using the VIO soft coagulation system: a mouse pulmonary air leak model.
Takahashi Y; Saito A; Sakuma Y; Tada M; Maki R; Takahashi M; Watanabe A
Surg Today; 2021 Sep; 51(9):1521-1529. PubMed ID: 33743052
[TBL] [Abstract][Full Text] [Related]
37. [Clinical study of bioabsorbable PGA sheets for suture reinforcement and use as artificial pleura].
Nakamura T; Shimizu Y; Mizuno H; Hitomi S; Kitano M; Matsunobe S
Nihon Kyobu Geka Gakkai Zasshi; 1992 Oct; 40(10):1828-31. PubMed ID: 1331268
[TBL] [Abstract][Full Text] [Related]
38. Low-voltage coagulation, polyglycolic acid sheets, and fibrin glue to control air leaks in lung surgery.
Kawai N; Kawaguchi T; Suzuki S; Yasukawa M; Tojo T; Taniguchi S
Gen Thorac Cardiovasc Surg; 2017 Dec; 65(12):705-709. PubMed ID: 28965258
[TBL] [Abstract][Full Text] [Related]
39. Staple line reinforcement during sleeve gastrectomy with a new type of reinforced stapler.
El Moussaoui I; Limbga A; Mehdi A
Minerva Chir; 2018 Apr; 73(2):127-132. PubMed ID: 29397639
[TBL] [Abstract][Full Text] [Related]
40. Functional assessment of a new staple line reinforcement in lung resection.
Downey DM; Michel M; Harre JG; Pratt JW
J Surg Res; 2006 Mar; 131(1):49-52. PubMed ID: 16129450
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]