  • 21. Cochlear Microphonics in Hearing Preservation Cochlear Implantees.
    Lorens A; Walkowiak A; Polak M; Kowalczuk A; Furmanek M; Skarzynski H; Obrycka A
    J Int Adv Otol; 2019 Dec; 15(3):345-351. PubMed ID: 31846910
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Intraoperative Intracochlear Electrocochleography and Residual Hearing Preservation Outcomes When Using Two Types of Slim Electrode Arrays in Cochlear Implantation.
    Ramos-Macias A; O'Leary S; Ramos-deMiguel A; Bester C; Falcon-González JC
    Otol Neurotol; 2019 Jun; 40(5S Suppl 1):S29-S37. PubMed ID: 31225820
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Delayed changes in auditory status in cochlear implant users with preserved acoustic hearing.
    Scheperle RA; Tejani VD; Omtvedt JK; Brown CJ; Abbas PJ; Hansen MR; Gantz BJ; Oleson JJ; Ozanne MV
    Hear Res; 2017 Jul; 350():45-57. PubMed ID: 28432874
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Multi-Frequency Electrocochleography and Electrode Scan to Identify Electrode Insertion Trauma during Cochlear Implantation.
    Saoji AA; Graham MK; Adkins WJ; Koka K; Carlson ML; Neff BA; Driscoll CLW; Fitzpatrick DC
    Brain Sci; 2023 Feb; 13(2):. PubMed ID: 36831873
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intracochlear Electrocochleography: Response Patterns During Cochlear Implantation and Hearing Preservation.
    Giardina CK; Brown KD; Adunka OF; Buchman CA; Hutson KA; Pillsbury HC; Fitzpatrick DC
    Ear Hear; 2019; 40(4):833-848. PubMed ID: 30335669
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Correlation of Electrophysiological Properties and Hearing Preservation in Cochlear Implant Patients.
    Dalbert A; Sim JH; Gerig R; Pfiffner F; Roosli C; Huber A
    Otol Neurotol; 2015 Aug; 36(7):1172-80. PubMed ID: 25839980
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Classification of Acoustic Hearing Preservation After Cochlear Implantation Using Electrocochleography.
    Sijgers L; Sorensen T; Soulby A; Boyle P; Dalbert A; Röösli C; Jablonski GE; Hamacher V; Greisiger R; Jiang D; Huber A; Pfiffner F
    Trends Hear; 2023; 27():23312165231220997. PubMed ID: 38105510
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A State-of-the-Art Method for Preserving Residual Hearing During Cochlear Implant Surgery.
    Dietz A; Linder P; Iso-Mustajärvi M
    J Vis Exp; 2023 May; (195):. PubMed ID: 37306464
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Monitoring of the Inner Ear Function During and After Cochlear Implant Insertion Using Electrocochleography.
    Haumann S; Imsiecke M; Bauernfeind G; Büchner A; Helmstaedter V; Lenarz T; Salcher RB
    Trends Hear; 2019; 23():2331216519833567. PubMed ID: 30909815
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intracochlear electrocochleography findings in cochlear implant recipients with auditory neuropathy spectrum disorder.
    Bayri Ulukan M; Ciprut A
    Int J Pediatr Otorhinolaryngol; 2023 Jul; 170():111596. PubMed ID: 37267660
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Digital Live Imaging of Intraoperative Electrocochleography - First Description of Feasibility and Hearing Preservation During Cochlear Implantation.
    Arweiler-Harbeck D; D'heygere V; Meyer M; Hans S; Waschkies L; Lang S; Anton K; Hessel H; Schneider A; Heiler T; Höing B
    Otol Neurotol; 2021 Oct; 42(9):1342-1346. PubMed ID: 34369444
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Relationship Between Intraoperative Electrocochleography Responses and Immediate Postoperative Bone Conduction Thresholds in Cochlear Implantation.
    Saoji AA; Graham MK; Adkins WJ; Nassiri AM; Neff BA; Carlson ML; Driscoll CLW
    Otol Neurotol; 2022 Sep; 43(8):e880-e887. PubMed ID: 35970166
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Electrocochleography triggered intervention successfully preserves residual hearing during cochlear implantation: Results of a randomised clinical trial.
    Bester C; Collins A; Razmovski T; Weder S; Briggs RJ; Wei B; Zakaria AF; Gerard JM; Mitchell-Innes A; Tykocinski M; Kennedy R; Iseli C; Dahm M; Ellul S; O'Leary S
    Hear Res; 2022 Dec; 426():108353. PubMed ID: 34600798
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Using the Implant Electrode Array to Conduct Real-time Intraoperative Hearing Monitoring During Pediatric Cochlear Implantation: Preliminary Experiences.
    Acharya AN; Tavora-Vieira D; Rajan GP
    Otol Neurotol; 2016 Feb; 37(2):e148-53. PubMed ID: 26756149
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Feasibility of Using Electrocochleography for Objective Estimation of Electro-Acoustic Interactions in Cochlear Implant Recipients with Residual Hearing.
    Koka K; Litvak LM
    Front Neurosci; 2017; 11():337. PubMed ID: 28674482
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Multi-Frequency Intraoperative Monitoring of Hearing Preservation during Cochlear Implantation.
    Skarżyński PH; Lorens A; Walkowiak A; Polak M; Skarżyński H
    Life (Basel); 2022 Apr; 12(5):. PubMed ID: 35629304
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Intracochlear Electrocochleography and Speech Perception Scores in Cochlear Implant Recipients.
    Valenzuela CV; Lichtenhan JT; Lefler SM; Koka K; Buchman CA; Ortmann AJ
    Laryngoscope; 2021 Oct; 131(10):E2681-E2688. PubMed ID: 34019310
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Intraoperative monitoring using cochlear microphonics in cochlear implant patients with residual hearing.
    Radeloff A; Shehata-Dieler W; Scherzed A; Rak K; Harnisch W; Hagen R; Mlynski R
    Otol Neurotol; 2012 Apr; 33(3):348-54. PubMed ID: 22377649
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Preliminary results and technique for electrophysiological intra-operative monitoring of residual hearing during cochlear implantation.
    Harris R; Cruise A; Gibson W; Bate K; Sanli H
    Cochlear Implants Int; 2011 Nov; 12(4):209-15. PubMed ID: 22251808
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Phantom Stimulation for Cochlear Implant Users With Residual Low-Frequency Hearing.
    Krüger B; Büchner A; Nogueira W
    Ear Hear; 2022; 43(2):631-645. PubMed ID: 34593687
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]