BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 38703482)

  • 1. A dual-mode label-free electrochemical immunosensor for ultrasensitive detection of procalcitonin by on-site vulcanization of dual-MOF heterostructure.
    Wen X; Zhang L; Wang Y; Dong X; Sun Y; Xu B; Li C
    Talanta; 2024 Aug; 275():126186. PubMed ID: 38703482
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrochemical immunosensor based on hollow Pt@Cu
    Liu J; Zhang Z; Dong J; Chen A; Qiu J; Li C
    Talanta; 2024 Jan; 266(Pt 2):125018. PubMed ID: 37572476
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A dual-mode PCT electrochemical immunosensor with CuCo
    Li Y; Liu L; Liu X; Ren Y; Xu K; Zhang N; Sun X; Yang X; Ren X; Wei Q
    Biosens Bioelectron; 2020 Sep; 163():112280. PubMed ID: 32421633
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dual-signaling and ultrasensitive detection for PCT based on the photoelectric and electrocatalytic hydrogen evolution signals of Pt/Mo-CoFeS.
    Duolihong B; Ma X; Liu R; Yue S; Xia X
    Talanta; 2024 Jun; 273():125945. PubMed ID: 38508124
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ce-MOF/COF/carbon nanotube hybrid composite: Construction of efficient electrochemical immune platform for amplifying detection performance of CA125.
    An Y; Dong S; Chen H; Guan L; Huang T
    Bioelectrochemistry; 2022 Oct; 147():108201. PubMed ID: 35809468
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Label-Free Electrochemical Immunosensor for Ultrasensitive Detection of Carbohydrate Antigen 125 Based on Antibody-Immobilized Biocompatible MOF-808/CNT.
    Biswas S; Lan Q; Xie Y; Sun X; Wang Y
    ACS Appl Mater Interfaces; 2021 Jan; 13(2):3295-3302. PubMed ID: 33400479
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Double electrochemiluminescence quenching effects of Fe
    Wang C; Zhang N; Wei D; Feng R; Fan D; Hu L; Wei Q; Ju H
    Biosens Bioelectron; 2019 Oct; 142():111521. PubMed ID: 31352225
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A dual signal-amplified electrochemiluminescence immunosensor based on core-shell CeO
    Shao X; Song X; Liu X; Yan L; Liu L; Fan D; Wei Q; Ju H
    Mikrochim Acta; 2021 Sep; 188(10):344. PubMed ID: 34528141
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ratiometric electrochemical immunosensor for the detection of procalcitonin based on the ratios of SiO
    Miao J; Du K; Li X; Xu X; Dong X; Fang J; Cao W; Wei Q
    Biosens Bioelectron; 2021 Jan; 171():112713. PubMed ID: 33059166
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A dual-mode label-free electrochemical immunosensor for ultrasensitive detection of procalcitonin based on g-C
    Xu X; Li X; Miao J; Liu L; Huang X; Wei Q; Cao W
    Analyst; 2021 May; 146(10):3169-3176. PubMed ID: 33999069
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A label-free electrochemical immunosensor based on encapsulated signal molecules in mesoporous silica-coated gold nanorods for ultrasensitive assay of procalcitonin.
    Feng YG; Wang XY; Wang ZW; Wang AJ; Mei LP; Luo X; Feng JJ
    Bioelectrochemistry; 2021 Aug; 140():107753. PubMed ID: 33631415
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel detection strategy for nitrofuran metabolite residues: Dual-mode competitive-type electrochemical immunosensor based on polyethyleneimine reduced graphene oxide/gold nanorods nanocomposite and silica-based multifunctional immunoprobe.
    Wang B; He B; Xie L; Cao X; Liang Z; Wei M; Jin H; Ren W; Suo Z; Xu Y
    Sci Total Environ; 2022 Dec; 853():158676. PubMed ID: 36096228
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ti
    Zhang M; Mei L; Zhang L; Wang X; Liao X; Qiao X; Hong C
    Bioelectrochemistry; 2021 Dec; 142():107943. PubMed ID: 34508921
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A dual-emitting immunosensor based on manganese dioxide nanoflowers and zinc sulfide quantum dots with enhanced electrochemiluminescence performance for the ultrasensitive detection of procalcitonin.
    Wang N; Yang J; Luo Z; Qin D; Wu Y; Deng B
    Analyst; 2023 May; 148(9):2122-2132. PubMed ID: 37038984
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dual-signal sandwich electrochemical immunosensor for amyloid β-protein detection based on Cu-Al
    Miao J; Li X; Li Y; Dong X; Zhao G; Fang J; Wei Q; Cao W
    Anal Chim Acta; 2019 Dec; 1089():48-55. PubMed ID: 31627818
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Label-free electrochemical biosensor for determination of procalcitonin based on graphene-wrapped Co nanoparticles encapsulated in carbon nanobrushes coupled with AuPtCu nanodendrites.
    Ge XY; Zhang JX; Feng YG; Wang AJ; Mei LP; Feng JJ
    Mikrochim Acta; 2022 Feb; 189(3):110. PubMed ID: 35178584
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Label-free electrochemical immunosensor for ultrasensitive detection of neuron-specific enolase based on enzyme-free catalytic amplification.
    Yin S; Zhao L; Ma Z
    Anal Bioanal Chem; 2018 Feb; 410(4):1279-1286. PubMed ID: 29247379
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrochemical immunoassay for procalcitonin antigen detection based on signal amplification strategy of multiple nanocomposites.
    Fang YS; Wang HY; Wang LS; Wang JF
    Biosens Bioelectron; 2014 Jan; 51():310-6. PubMed ID: 23978454
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 3D carbonized wood-based integrated electrochemical immunosensor for ultrasensitive detection of procalcitonin antigen.
    Huang J; Cheng W; Li Y
    Talanta; 2022 Feb; 238(Pt 1):122991. PubMed ID: 34857324
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An Electrochemical Immunosensor for the Determination of Procalcitonin Using the Gold-Graphene Interdigitated Electrode.
    Amouzadeh Tabrizi M; Acedo P
    Biosensors (Basel); 2022 Sep; 12(10):. PubMed ID: 36290909
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.