BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 38705477)

  • 1. Residual risk of Pseudomonas aeruginosa waterborne contamination in an intensive care unit despite the presence of filters at all water points-of-use.
    Royer G; Virieux-Petit M; Aujoulat F; Hersent C; Baranovsky S; Hammer-Dedet F; Masnou A; Marchandin H; Corne P; Jumas-Bilak E; Romano-Bertrand S
    J Hosp Infect; 2024 Jul; 149():155-164. PubMed ID: 38705477
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tap out: reducing waterborne Pseudomonas aeruginosa transmission in an intensive care unit.
    Garvey MI; Wilkinson MAC; Holden KL; Martin T; Parkes J; Holden E
    J Hosp Infect; 2019 May; 102(1):75-81. PubMed ID: 30071267
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continued transmission of Pseudomonas aeruginosa from a wash hand basin tap in a critical care unit.
    Garvey MI; Bradley CW; Tracey J; Oppenheim B
    J Hosp Infect; 2016 Sep; 94(1):8-12. PubMed ID: 27249962
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Infection control by point-of-use water filtration in an intensive care unit - a Hungarian case study.
    Barna Z; Antmann K; Pászti J; Bánfi R; Kádár M; Szax A; Németh M; Szegő E; Vargha M
    J Water Health; 2014 Dec; 12(4):858-67. PubMed ID: 25473995
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of intensive care unit relocation and role of tap water on an outbreak of Pseudomonas aeruginosa expressing OprD-mediated resistance to imipenem.
    Tran-Dinh A; Neulier C; Amara M; Nebot N; Troché G; Breton N; Zuber B; Cavelot S; Pangon B; Bedos JP; Merrer J; Grimaldi D
    J Hosp Infect; 2018 Nov; 100(3):e105-e114. PubMed ID: 29857026
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Exogenous acquisition of Pseudomonas aeruginosa in intensive care units: a prospective multi-centre study (DYNAPYO study).
    Coppry M; Leroyer C; Saly M; Venier AG; Slekovec C; Bertrand X; Parer S; Alfandari S; Cambau E; Megarbane B; Lawrence C; Clair B; Lepape A; Cassier P; Trivier D; Boyer A; Boulestreau H; Asselineau J; Dubois V; Thiébaut R; Rogues AM
    J Hosp Infect; 2020 Jan; 104(1):40-45. PubMed ID: 31419468
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Common RAPD pattern of Pseudomonas aeruginosa from patients and tap water in a medical intensive care unit.
    Trautmann M; Bauer C; Schumann C; Hahn P; Höher M; Haller M; Lepper PM
    Int J Hyg Environ Health; 2006 Jul; 209(4):325-31. PubMed ID: 16740415
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Bundle of Measures to Control an Outbreak of Pseudomonas aeruginosa Associated With P-Trap Contamination.
    Gbaguidi-Haore H; Varin A; Cholley P; Thouverez M; Hocquet D; Bertrand X
    Infect Control Hosp Epidemiol; 2018 Feb; 39(2):164-169. PubMed ID: 29417923
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Nosocomial infections caused by Pseudomonas aeruginosa: Exogenous or endogenous origin of this bacterium?].
    Floret N; Bertrand X; Thouverez M; Talon D
    Pathol Biol (Paris); 2009 Feb; 57(1):9-12. PubMed ID: 18848405
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contaminated feeding bottles: the source of an outbreak of Pseudomonas aeruginosa infections in a neonatal intensive care unit.
    Sánchez-Carrillo C; Padilla B; Marín M; Rivera M; Cercenado E; Vigil D; Sánchez-Luna M; Bouza E
    Am J Infect Control; 2009 Mar; 37(2):150-4. PubMed ID: 19059675
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tracking the spread routes of opportunistic premise plumbing pathogens in a haematology unit with water points-of-use protected by antimicrobial filters.
    Baranovsky S; Jumas-Bilak E; Lotthé A; Marchandin H; Parer S; Hicheri Y; Romano-Bertrand S
    J Hosp Infect; 2018 Jan; 98(1):53-59. PubMed ID: 28760634
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of transmission pathways of Pseudomonas aeruginosa between patients and tap water outlets.
    Reuter S; Sigge A; Wiedeck H; Trautmann M
    Crit Care Med; 2002 Oct; 30(10):2222-8. PubMed ID: 12394948
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ecology of Pseudomonas aeruginosa in the intensive care unit and the evolving role of water outlets as a reservoir of the organism.
    Trautmann M; Lepper PM; Haller M
    Am J Infect Control; 2005 Jun; 33(5 Suppl 1):S41-9. PubMed ID: 15940115
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pseudomonas aeruginosa intensive care unit outbreak: winnowing of transmissions with molecular and genomic typing.
    Parcell BJ; Oravcova K; Pinheiro M; Holden MTG; Phillips G; Turton JF; Gillespie SH
    J Hosp Infect; 2018 Mar; 98(3):282-288. PubMed ID: 29229490
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Successful application of the DiversiLab repetitive-sequence-based PCR typing system for confirmation of the circulation of a multiresistant Pseudomonas aeruginosa clone in different hospital wards.
    Ratkai C; Peixe LV; Grosso F; Freitas AR; Antunes P; Fodor E; Hajdú E; Nagy E
    Diagn Microbiol Infect Dis; 2010 Jun; 67(2):202-6. PubMed ID: 20338712
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Waterborne Pseudomonas aeruginosa transmission in a hematology unit?
    Garvey MI; Bradley CW; Holden E
    Am J Infect Control; 2018 Apr; 46(4):383-386. PubMed ID: 29195780
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New genotyping method discovers sustained nosocomial Pseudomonas aeruginosa outbreak in an intensive care burn unit.
    Tissot F; Blanc DS; Basset P; Zanetti G; Berger MM; Que YA; Eggimann P; Senn L
    J Hosp Infect; 2016 Sep; 94(1):2-7. PubMed ID: 27451039
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of pulsed-field gel electrophoresis as an epidemiologic tool during an outbreak of Pseudomonas aeruginosa lung infections in an intensive care unit.
    Talon D; Capellier G; Boillot A; Michel-Briand Y
    Intensive Care Med; 1995 Dec; 21(12):996-1002. PubMed ID: 8750124
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hand soap contamination by Pseudomonas aeruginosa in a tertiary care hospital: no evidence of impact on patients.
    Blanc DS; Gomes Magalhaes B; Abdelbary M; Prod'hom G; Greub G; Wasserfallen JB; Genoud P; Zanetti G; Senn L
    J Hosp Infect; 2016 May; 93(1):63-7. PubMed ID: 27021398
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bronchoscope-related Pseudomonas aeruginosa pseudo-outbreak attributed to contaminated rinse water.
    Zhang Y; Zhou H; Jiang Q; Wang Q; Li S; Huang Y
    Am J Infect Control; 2020 Jan; 48(1):26-32. PubMed ID: 31358417
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.