BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 38707)

  • 1. [Harmful interference between preoperative prophylactic cardiac pacemaker and cutting diathermy. Case report].
    Protin F; Dodinot B; Lefèvre JC; Laxenaire MC
    Ann Anesthesiol Fr; 1979; 20(2):127-30. PubMed ID: 38707
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Prophylactic use of a transvenous pacing catheter. Involvement of the external pacemaker in 2 fatal cases].
    Roy A; Gauthier M; Hussonnois JL
    Arch Mal Coeur Vaiss; 1972 Nov; 65(11):1371-4. PubMed ID: 4121002
    [No Abstract]   [Full Text] [Related]  

  • 3. Electromagnetic field interference and cardiac pacemakers.
    Jones SL
    Phys Ther; 1976 Sep; 56(9):1013-8. PubMed ID: 959327
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Pacemaker-treated patients and electromagnetic interference during cardiac surgery].
    Shigenobu M; Teramoto S
    Kyobu Geka; 1987 Nov; 40(12):988-91. PubMed ID: 3437635
    [No Abstract]   [Full Text] [Related]  

  • 5. Ventricular fibrillation induced by an implanted cardiac pacemaker. Report of a successfully treated case.
    Ottinger LW; Austen WG; Wheeler EO
    N Engl J Med; 1965 Dec; 273(26):1426-8. PubMed ID: 5848417
    [No Abstract]   [Full Text] [Related]  

  • 6. [Syncopal attacks due to ventricular tachyarrhythmias ("torsade de pointe type") in a patient with a PM of hysteresis type (author's transl)].
    Speca G; Di Sabatino P; Potena A
    G Ital Cardiol; 1978; 8 Suppl 1():283-8. PubMed ID: 754966
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Left ventricular mechanical assist devices and cardiac device interactions: an observational case series.
    Foo D; Walker BD; Kuchar DL; Thorburn CW; Tay A; Hayward CS; Macdonald P; Keogh A; Kotlyar E; Spratt P; Jansz P
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):879-87. PubMed ID: 19572863
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Taser-induced rapid ventricular myocardial capture demonstrated by pacemaker intracardiac electrograms.
    Cao M; Shinbane JS; Gillberg JM; Saxon LA; Swerdlow CD
    J Cardiovasc Electrophysiol; 2007 Aug; 18(8):876-9. PubMed ID: 17573837
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Cathode stimulation as a cause of ventricular fibrillation induced by a pacemaker. Report of a case].
    Vera Almazán A; Alonso Pulpón L; Lezaun Burgui R; Puente Arús A; Teresa Galván E; Artaza Andrade M
    Rev Esp Cardiol; 1980; 33(6):617-20. PubMed ID: 7209090
    [No Abstract]   [Full Text] [Related]  

  • 10. Cardiac pacemaker induced ventricular fibrillation during surgical diathermy.
    Orland HJ; Jones D
    Anaesth Intensive Care; 1975 Nov; 3(4):321-6. PubMed ID: 1211612
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Abnormal pacing following defibrillation - exit block after microdislocation of the electrode (author's transl)].
    Wehr M; Schmitt CG; Köhler F; Crayen P
    Z Kardiol; 1980 Dec; 69(12):840-4. PubMed ID: 7281867
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pacemaker-induced repetitive firing: report of two cases.
    Grondin P; Lepage G; Karamehmet A; Catonguay Y; Meere C
    Can Med Assoc J; 1967 Jun; 96(22):1477-9. PubMed ID: 6025725
    [No Abstract]   [Full Text] [Related]  

  • 13. Electrical safety: fibrillation thresholds with 50 Hz leakage currents in man and animals.
    Raftery EB; Green H; Gregory I
    Br Heart J; 1973 Aug; 35(8):864. PubMed ID: 4729852
    [No Abstract]   [Full Text] [Related]  

  • 14. Endoscopic diathermy in patients with cardiac pacemakers.
    Veitch A; Fairclough P
    Endoscopy; 1998 Aug; 30(6):544-7. PubMed ID: 9746163
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cross-ventricular pacemaker-mediated tachycardia by myopotential induction during biventricular pacing.
    Guenoun M; Hero M; Roux O; Mainardis M
    Pacing Clin Electrophysiol; 2005 Jun; 28(6):585-7. PubMed ID: 15955194
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of the Shaw Scalpel in pacemaker operations.
    Erdman S; Levinsky L; Strasberg B; Agmon J; Levy MJ
    J Thorac Cardiovasc Surg; 1985 Feb; 89(2):304-7. PubMed ID: 3968915
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Pacemaker-induced ventricular fibrillation].
    Koch R; Wiessmann B
    Z Kreislaufforsch; 1971 Sep; 60(9):842-50. PubMed ID: 5116919
    [No Abstract]   [Full Text] [Related]  

  • 18. The risks of diathermy in the urological patient with a pacemaker or an automatic internal cardiac defibrillator.
    Meyer JP; Crew J
    BJU Int; 2008 Mar; 101(5):528-9. PubMed ID: 18257854
    [No Abstract]   [Full Text] [Related]  

  • 19. Rapid ventricular pacing due to electrocautery: a case report and review.
    Wilson S; Neustein SN; Camunas J
    Mt Sinai J Med; 2006 Oct; 73(6):880-3. PubMed ID: 17117315
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Orthodromic pacemaker-mediated tachycardia in a biventricular system without an atrial electrode.
    Berruezo A; Mont L; Scalise A; Brugada J
    J Cardiovasc Electrophysiol; 2004 Sep; 15(9):1100-2. PubMed ID: 15363087
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.