  • 1. Angulation and curvature of aortic landing zone affect implantation depth in transcatheter aortic valve implantation.
    Gorla R; Oliva OA; Arzuffi L; Milani V; Saitta S; Squillace M; Poletti E; Tusa M; Votta E; Brambilla N; Testa L; Bedogni F; Sturla F
    Sci Rep; 2024 May; 14(1):10409. PubMed ID: 38710782
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Aortic Angulation Attenuates Procedural Success Following Self-Expandable But Not Balloon-Expandable TAVR.
    Abramowitz Y; Maeno Y; Chakravarty T; Kazuno Y; Takahashi N; Kawamori H; Mangat G; Cheng W; Jilaihawi H; Makkar RR
    JACC Cardiovasc Imaging; 2016 Aug; 9(8):964-72. PubMed ID: 27424244
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcatheter aortic valve implantation in patients with a small aortic annulus: performance of supra-, intra- and infra-annular transcatheter heart valves.
    Voigtländer L; Kim WK; Mauri V; Goßling A; Renker M; Sugiura A; Linder M; Schmidt T; Schofer N; Westermann D; Reichenspurner H; Nickenig G; Blankenberg S; Hamm C; Conradi L; Adam M; Sinning JM; Seiffert M
    Clin Res Cardiol; 2021 Dec; 110(12):1957-1966. PubMed ID: 34387736
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Predictors for low TAVI-prosthesis position assessed by fusion imaging of pre- and post-procedural CT angiography.
    Breitbart P; Pache G; Minners J; Hein M; Schröfel H; Neumann FJ; Ruile P
    Clin Res Cardiol; 2021 Jan; 110(1):93-101. PubMed ID: 32399896
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of balloon aortic valvuloplasty on transcatheter aortic valve implantation with self-expandable valve.
    Vavuranakis M; Lavda M; Vrachatis D; Papaioannou TG; Kalogeras K; Kolokathis AM; Kariori M; Lilly S; Siasos G; Oikonomou E; Toutouzas K; Stasinopoulou M; Deliveliotis K; Tousoulis D
    J Cardiol; 2017 Jan; 69(1):245-252. PubMed ID: 27177535
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
    Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification.
    Kim WK; Blumenstein J; Liebetrau C; Rolf A; Gaede L; Van Linden A; Arsalan M; Doss M; Tijssen JGP; Hamm CW; Walther T; Möllmann H
    Clin Res Cardiol; 2017 Dec; 106(12):995-1004. PubMed ID: 28795259
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of aortic angle on transcatheter aortic valve implantation outcome with Evolut-R, Portico, and Acurate-NEO.
    Gorla R; De Marco F; Garatti A; Bianchi G; Popolo Rubbio A; Acerbi E; Casenghi M; Spagnolo P; Brambilla N; Testa L; Agnifili ML; Tusa M; Bedogni F
    Catheter Cardiovasc Interv; 2021 Jan; 97(1):E135-E145. PubMed ID: 32400068
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Left Bundle Branch Block after Transcatheter Aortic Valve Implantation with Edwards Sapien 3 Valve: Influence of the Valve Depth Implantation.
    Unzué L; García E; Díaz-Antón B; Rodríguez-Rodrigo FJ; Rodríguez Del Río M; Teijeiro R; Medina J; Parra FJ
    Cardiovasc Revasc Med; 2019 Nov; 20(11):949-955. PubMed ID: 30745060
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Implantation depth and its influence on complications after TAVI with self-expanding valves.
    Breitbart P; Minners J; Hein M; Schröfel H; Neumann FJ; Ruile P
    Int J Cardiovasc Imaging; 2021 Oct; 37(10):3081-3092. PubMed ID: 33988801
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Device landing zone calcification and its impact on residual regurgitation after transcatheter aortic valve implantation with different devices.
    Seiffert M; Fujita B; Avanesov M; Lunau C; Schön G; Conradi L; Prashovikj E; Scholtz S; Börgermann J; Scholtz W; Schäfer U; Lund G; Ensminger S; Treede H
    Eur Heart J Cardiovasc Imaging; 2016 May; 17(5):576-84. PubMed ID: 26160399
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computed tomography predictors of structural valve degeneration in patients undergoing transcatheter aortic valve implantation with balloon-expandable prostheses.
    Guglielmo M; Fusini L; Muratori M; Tamborini G; Mantegazza V; Andreini D; Annoni A; Babbaro M; Baggiano A; Conte E; Carriero S; Formenti A; Guaricci AI; Mancini E; Mollace R; Muscogiuri G; Mushtaq S; Ricci F; Rossi A; Scafuri S; Alushi B; Cau C; Cau R; Cesarano M; Saba L; Rabbat M; Pepi M; Pontone G
    Eur Radiol; 2022 Sep; 32(9):6017-6027. PubMed ID: 35364711
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic Estimation of Optimal Deployment of Transcatheter Aortic Valve Implantation Using Computed Tomography.
    Kerner A; Abadi S; Dotan R; Javitt M; Aronson D; Lessick J
    J Heart Valve Dis; 2017 Mar; 26(2):130-138. PubMed ID: 28820541
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety and Efficacy of Self-Expanding TAVR in Patients With Aortoventricular Angulation.
    Popma JJ; Reardon MJ; Yakubov SJ; Hermiller JB; Harrison JK; Gleason TG; Conte JV; Deeb GM; Chetcuti S; Oh JK; Boulware MJ; Huang J; Adams DH;
    JACC Cardiovasc Imaging; 2016 Aug; 9(8):973-81. PubMed ID: 27491485
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of balloon-expandable vs. self-expandable valves in patients undergoing transfemoral transcatheter aortic valve implantation: from the CENTER-collaboration.
    Vlastra W; Chandrasekhar J; Muñoz-Garcia AJ; Tchétché D; de Brito FS; Barbanti M; Kornowski R; Latib A; D'Onofrio A; Ribichini F; Baan J; Tijssen JGP; Trillo-Nouche R; Dumonteil N; Abizaid A; Sartori S; D'Errigo P; Tarantini G; Lunardi M; Orvin K; Pagnesi M; Del Valle R; Modine T; Dangas G; Mehran R; Piek JJ; Delewi R
    Eur Heart J; 2019 Feb; 40(5):456-465. PubMed ID: 30590565
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of "high" implantation on functionality of self-expandable bioprosthesis during the short- and long-term outcome of patients who undergo transcatheter aortic valve implantation: Is high implantation beneficial?
    Vavuranakis M; Kariori M; Scott L; Kalogeras K; Siasos G; Vrachatis D; Lavda M; Kalantzis C; Vavuranakis M; Bei E; Moldovan CM; Oikonomou E; Stefanadis C; Tousoulis D
    Cardiovasc Ther; 2018 Jun; 36(3):e12330. PubMed ID: 29608814
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Factors associated with a high or low implantation of self-expanding devices in TAVR.
    Veulemans V; Maier O; Piayda K; Berning KL; Binnebößel S; Polzin A; Afzal S; Dannenberg L; Horn P; Jung C; Westenfeld R; Kelm M; Zeus T
    Clin Res Cardiol; 2021 Dec; 110(12):1930-1938. PubMed ID: 34165599
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aortic annulus angulation does not attenuate procedural success of transcatheter aortic valve replacement using a novel self-expanding bioprosthesis.
    D'Ancona G; Kische S; El-Mawardy M; Dißmann M; Heinze H; Zohlnhöfer-Momm D; Gürer H; Ince H
    Heart Vessels; 2019 Dec; 34(12):1969-1975. PubMed ID: 31134380
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative analysis of balloon- versus mechanically-expandable transcatheter heart valves considering landing zone calcification.
    Schofer N; Deuschl F; Schön G; Seiffert M; Linder M; Schaefer A; Schirmer J; Lubos E; Reichenspurner H; Blankenberg S; Conradi L; Schäfer U
    J Cardiol; 2018 Jun; 71(6):540-546. PubMed ID: 29548665
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correlation of CoreValve implantation 'true cover index' with short and mid-term aortic regurgitation: A novel index.
    Vavuranakis M; Kalogeras K; Lavda M; Kolokathis MA; Papaioannou T; Oikonomou E; Stasinopoulou M; Vrachatis D; Moldovan C; Kariori M; Bei E; Vaina S; Lazaros G; Katsarou O; Siasos G; Tousoulis D
    Int J Cardiol; 2016 Nov; 223():482-487. PubMed ID: 27544611
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]