These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
151 related articles for article (PubMed ID: 38711559)
1. First clinical implementation of insertion force measurement in cochlear implantation surgery. Rau TS; Böttcher-Rebmann G; Schell V; Cramer J; Artukarslan E; Baier C; Lenarz T; Salcher R Front Neurol; 2024; 15():1400455. PubMed ID: 38711559 [TBL] [Abstract][Full Text] [Related]
2. Preclinical evaluation of a tool for insertion force measurements in cochlear implant surgery. Böttcher-Rebmann G; Schell V; Zuniga MG; Salcher R; Lenarz T; Rau TS Int J Comput Assist Radiol Surg; 2023 Nov; 18(11):2117-2124. PubMed ID: 37310560 [TBL] [Abstract][Full Text] [Related]
3. A Tool to Enable Intraoperative Insertion Force Measurements for Cochlear Implant Surgery. Bottcher-Rebmann G; Schell V; Budde L; Zuniga MG; Baier C; Lenarz T; Rau TS IEEE Trans Biomed Eng; 2023 May; 70(5):1643-1650. PubMed ID: 36423317 [TBL] [Abstract][Full Text] [Related]
4. Intraoperative force and electrocochleography measurements in an animal model of cochlear implantation. Lo J; Bester C; Collins A; Newbold C; Hampson A; Chambers S; Eastwood H; O'Leary S Hear Res; 2018 Feb; 358():50-58. PubMed ID: 29153256 [TBL] [Abstract][Full Text] [Related]
5. Development and Evaluation of a Reusable, Force Measuring Tool for the Robot-Assisted Insertion of Cochlear Implant Electrode Arrays. Aebischer P; Sarbach B; Weder S; Mantokoudis G; Caversaccio M; Anschuetz L IEEE Trans Biomed Eng; 2024 Jul; PP():. PubMed ID: 38995714 [TBL] [Abstract][Full Text] [Related]
6. A State-of-the-Art Method for Preserving Residual Hearing During Cochlear Implant Surgery. Dietz A; Linder P; Iso-Mustajärvi M J Vis Exp; 2023 May; (195):. PubMed ID: 37306464 [TBL] [Abstract][Full Text] [Related]
7. Robotic assistance during cochlear implantation: the rationale for consistent, controlled speed of electrode array insertion. Kashani RG; Henslee A; Nelson RF; Hansen MR Front Neurol; 2024; 15():1335994. PubMed ID: 38318440 [TBL] [Abstract][Full Text] [Related]
8. Damage to inner ear structure during cochlear implantation: Correlation between insertion force and radio-histological findings in temporal bone specimens. De Seta D; Torres R; Russo FY; Ferrary E; Kazmitcheff G; Heymann D; Amiaud J; Sterkers O; Bernardeschi D; Nguyen Y Hear Res; 2017 Feb; 344():90-97. PubMed ID: 27825860 [TBL] [Abstract][Full Text] [Related]
9. Intracochlear Electrocochleography: Response Patterns During Cochlear Implantation and Hearing Preservation. Giardina CK; Brown KD; Adunka OF; Buchman CA; Hutson KA; Pillsbury HC; Fitzpatrick DC Ear Hear; 2019; 40(4):833-848. PubMed ID: 30335669 [TBL] [Abstract][Full Text] [Related]
10. Friction force measurement during cochlear implant insertion: application to a force-controlled insertion tool design. Miroir M; Nguyen Y; Kazmitcheff G; Ferrary E; Sterkers O; Grayeli AB Otol Neurotol; 2012 Aug; 33(6):1092-100. PubMed ID: 22772019 [TBL] [Abstract][Full Text] [Related]
12. Impact of the insertion speed of cochlear implant electrodes on the insertion forces. Kontorinis G; Lenarz T; Stöver T; Paasche G Otol Neurotol; 2011 Jun; 32(4):565-70. PubMed ID: 21478788 [TBL] [Abstract][Full Text] [Related]
13. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array. Mirsalehi M; Rau TS; Harbach L; Hügl S; Mohebbi S; Lenarz T; Majdani O Eur Arch Otorhinolaryngol; 2017 May; 274(5):2131-2140. PubMed ID: 28238160 [TBL] [Abstract][Full Text] [Related]
14. Design of a Tool Integrating Force Sensing With Automated Insertion in Cochlear Implantation. Schurzig D; Labadie RF; Hussong A; Rau TS; Webster RJ IEEE ASME Trans Mechatron; 2012 Apr; 17(2):381-389. PubMed ID: 23482414 [TBL] [Abstract][Full Text] [Related]
15. Three-Dimensional Force Profile During Cochlear Implantation Depends on Individual Geometry and Insertion Trauma. Avci E; Nauwelaers T; Hamacher V; Kral A Ear Hear; 2017; 38(3):e168-e179. PubMed ID: 28045786 [TBL] [Abstract][Full Text] [Related]
16. Robotics, automation, active electrode arrays, and new devices for cochlear implantation: A contemporary review. De Seta D; Daoudi H; Torres R; Ferrary E; Sterkers O; Nguyen Y Hear Res; 2022 Feb; 414():108425. PubMed ID: 34979455 [TBL] [Abstract][Full Text] [Related]
17. Anatomically and mechanically accurate scala tympani model for electrode insertion studies. Starovoyt A; Shaheen E; Putzeys T; Kerckhofs G; Politis C; Wouters J; Verhaert N Hear Res; 2023 Mar; 430():108707. PubMed ID: 36773540 [TBL] [Abstract][Full Text] [Related]
18. Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion. Gwon TM; Min KS; Kim JH; Oh SH; Lee HS; Park MH; Kim SJ Biomed Microdevices; 2015 Apr; 17(2):32. PubMed ID: 25681972 [TBL] [Abstract][Full Text] [Related]
19. An automated insertion tool for cochlear implants with integrated force sensing capability. Kobler JP; Beckmann D; Rau TS; Majdani O; Ortmaier T Int J Comput Assist Radiol Surg; 2014 May; 9(3):481-94. PubMed ID: 23959671 [TBL] [Abstract][Full Text] [Related]
20. Intraoperative Intracochlear Electrocochleography and Residual Hearing Preservation Outcomes When Using Two Types of Slim Electrode Arrays in Cochlear Implantation. Ramos-Macias A; O'Leary S; Ramos-deMiguel A; Bester C; Falcon-González JC Otol Neurotol; 2019 Jun; 40(5S Suppl 1):S29-S37. PubMed ID: 31225820 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]