These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 38716058)

  • 1. Analytical considerations for accurately capturing the relevant species contributing to vitamin D status in liquid chromatography-tandem mass spectrometry assays.
    Volmer DA; Stokes CS
    Anal Sci Adv; 2022 Feb; 3(1-2):14-20. PubMed ID: 38716058
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Misleading measures in Vitamin D analysis: a novel LC-MS/MS assay to account for epimers and isobars.
    Shah I; James R; Barker J; Petroczi A; Naughton DP
    Nutr J; 2011 May; 10():46. PubMed ID: 21569549
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On the isobaric space of 25-hydroxyvitamin D in human serum: potential for interferences in liquid chromatography/tandem mass spectrometry, systematic errors and accuracy issues.
    Qi Y; Geib T; Schorr P; Meier F; Volmer DA
    Rapid Commun Mass Spectrom; 2015 Jan; 29(1):1-9. PubMed ID: 25462357
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of a new vitamin D blood test on the Emirati population.
    Shah I; Al-Dabbagh B; Gariballa S; Al-Menhali A; Muhammad N; Yasin J; Ashraf SS
    J Steroid Biochem Mol Biol; 2018 Jun; 180():118-128. PubMed ID: 29432962
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multiplex LC-MS/MS for simultaneous determination of 25-hydroxyvitamin D, 24,25-dihydroxyvitamin D
    Ko DH; Jun SH; Nam Y; Song SH; Han M; Yun YM; Lee K; Song J
    J Steroid Biochem Mol Biol; 2021 Feb; 206():105796. PubMed ID: 33259939
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and application of a LC-MS/MS assay for simultaneous analysis of 25-hydroxyvitamin-D and 3-epi-25-hydroxyvitamin-D metabolites in canine serum.
    Hurst EA; Homer NZ; Denham SG; MacFarlane E; Campbell S; Boswinkel M; Mellanby RJ
    J Steroid Biochem Mol Biol; 2020 May; 199():105598. PubMed ID: 31958632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 2-fluoro-1-methylpyridinium p-toluene sulfonate: a new LC-MS/MS derivatization reagent for vitamin D metabolites.
    Alexandridou A; Volmer DA
    J Lipid Res; 2023 Aug; 64(8):100409. PubMed ID: 37406930
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.
    Tai SS; Bedner M; Phinney KW
    Anal Chem; 2010 Mar; 82(5):1942-8. PubMed ID: 20136128
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry.
    Vogeser M
    J Steroid Biochem Mol Biol; 2010 Aug; 121(3-5):565-73. PubMed ID: 20206693
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D
    Wise SA; Camara JE; Burdette CQ; Hahm G; Nalin F; Kuszak AJ; Merkel J; Durazo-Arvizu RA; Williams EL; Hoofnagle AN; Ivison F; Fischer R; van den Ouweland JMW; Ho CS; Law EWK; Simard JN; Gonthier R; Holmquist B; Meadows S; Cox L; Robyak K; Creer MH; Fitzgerald R; Clarke MW; Breen N; Lukas P; Cavalier É; Sempos CT
    Anal Bioanal Chem; 2022 Jan; 414(1):333-349. PubMed ID: 34432104
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Candidate Reference Measurement Procedure for the Determination of (24R),25-Dihydroxyvitamin D3 in Human Serum Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry.
    Tai SS; Nelson MA
    Anal Chem; 2015 Aug; 87(15):7964-70. PubMed ID: 26171884
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Vitamin D Metabolism and Profiling in Veterinary Species.
    Hurst EA; Homer NZ; Mellanby RJ
    Metabolites; 2020 Sep; 10(9):. PubMed ID: 32942601
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Vitamin D Status in Children With Short Stature: Accurate Determination of Serum Vitamin D Components Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry.
    Xu B; Feng Y; Gan L; Zhang Y; Jiang W; Feng J; Yu L
    Front Endocrinol (Lausanne); 2021; 12():707283. PubMed ID: 34721288
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparing derivatization reagents for quantitative LC-MS/MS analysis of a variety of vitamin D metabolites.
    Alexandridou A; Schorr P; Volmer DA
    Anal Bioanal Chem; 2023 Aug; 415(19):4689-4701. PubMed ID: 37219579
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Differential extraction of endogenous and exogenous 25-OH-vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging.
    Lankes U; Elder PA; Lewis JG; George P
    Ann Clin Biochem; 2015 Jan; 52(Pt 1):151-60. PubMed ID: 24714680
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An LC-MS/MS Method for Analysis of Vitamin D Metabolites and C3 Epimers in Mice Serum: Oral Supplementation Compared to UV Irradiation.
    Sohail A; Al Menhali A; Hisaindee S; Shah I
    Molecules; 2021 Aug; 26(17):. PubMed ID: 34500616
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analysis of vitamin D metabolic markers by mass spectrometry: Recent progress regarding the "gold standard" method and integration into clinical practice.
    Alexandridou A; Schorr P; Stokes CS; Volmer DA
    Mass Spectrom Rev; 2023; 42(5):1647-1687. PubMed ID: 34967037
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Two-dimensional liquid chromatography coupled to tandem mass spectrometry for vitamin D metabolite profiling including the C3-epimer-25-monohydroxyvitamin D3.
    Mena-Bravo A; Priego-Capote F; Luque de Castro MD
    J Chromatogr A; 2016 Jun; 1451():50-57. PubMed ID: 27180887
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Triple Quadrupole Versus High Resolution Quadrupole-Time-of-Flight Mass Spectrometry for Quantitative LC-MS/MS Analysis of 25-Hydroxyvitamin D in Human Serum.
    Geib T; Sleno L; Hall RA; Stokes CS; Volmer DA
    J Am Soc Mass Spectrom; 2016 Aug; 27(8):1404-10. PubMed ID: 27154021
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved quantitative LC-MS/MS analysis of vitamin D metabolites in serum after one-pot double derivatization.
    Schorr P; Stokes CS; Volmer DA
    J Pharm Biomed Anal; 2023 Sep; 234():115522. PubMed ID: 37329649
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.