These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 38716153)

  • 1. Quadrupole detection FT-ICR mass spectrometry offers deep profiling of residue oil: A systematic comparison of 2ω 7 Tesla versus 15 Tesla instruments.
    Ge J; Ma C; Qi Y; Wang X; Wang W; Hu M; Hu Q; Yi YB; Shi D; Yue FJ; Li SL; Volmer DA
    Anal Sci Adv; 2021 Jun; 2(5-6):272-278. PubMed ID: 38716153
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of FT-ICR MS Equipped with Quadrupole Detection for Analysis of Crude Oil.
    Cho E; Witt M; Hur M; Jung MJ; Kim S
    Anal Chem; 2017 Nov; 89(22):12101-12107. PubMed ID: 29068664
    [TBL] [Abstract][Full Text] [Related]  

  • 3. FT-ICR Mass Spectrometry Imaging at Extreme Mass Resolving Power Using a Dynamically Harmonized ICR Cell with 1ω or 2ω Detection.
    Tiquet M; La Rocca R; Kirnbauer S; Zoratto S; Van Kruining D; Quinton L; Eppe G; Martinez-Martinez P; Marchetti-Deschmann M; De Pauw E; Far J
    Anal Chem; 2022 Jul; 94(26):9316-9326. PubMed ID: 35604839
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved Dynamic Range, Resolving Power, and Sensitivity Achievable with FT-ICR Mass Spectrometry at 21 T Reveals the Hidden Complexity of Natural Organic Matter.
    Bahureksa W; Borch T; Young RB; Weisbrod CR; Blakney GT; McKenna AM
    Anal Chem; 2022 Aug; 94(32):11382-11389. PubMed ID: 35917115
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assigning product ions from complex MS/MS spectra: the importance of mass uncertainty and resolving power.
    Sleno L; Volmer DA; Marshall AG
    J Am Soc Mass Spectrom; 2005 Feb; 16(2):183-98. PubMed ID: 15694769
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Chemical diversity of dissolved organic matter revealed by ultra performance liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry].
    Ma C; Ni HX; Qi YL
    Se Pu; 2023 Aug; 41(8):662-672. PubMed ID: 37534553
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fourier transform ion cyclotron resonance (FT ICR) mass spectrometry: Theory and simulations.
    Nikolaev EN; Kostyukevich YI; Vladimirov GN
    Mass Spectrom Rev; 2016; 35(2):219-58. PubMed ID: 24515872
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: A National Resource for Ultrahigh Resolution Mass Analysis.
    Hendrickson CL; Quinn JP; Kaiser NK; Smith DF; Blakney GT; Chen T; Marshall AG; Weisbrod CR; Beu SC
    J Am Soc Mass Spectrom; 2015 Sep; 26(9):1626-32. PubMed ID: 26091892
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fourier transform ion cyclotron resonance mass spectrometry at the true cyclotron frequency.
    Nagornov KO; Tsybin OY; Nicol E; Kozhinov AN; Tsybin YO
    Mass Spectrom Rev; 2022 Mar; 41(2):314-337. PubMed ID: 33462876
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of frequency multiple FT-ICR-MS signal acquisition for improved proteome research.
    Park SG; Mohr JP; Anderson GA; Bruce JE
    Int J Mass Spectrom; 2021 Jul; 465():. PubMed ID: 33897275
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-resolution Fourier transform ion cyclotron resonance mass spectrometry with increased throughput for biomolecular analysis.
    Nagornov KO; Gorshkov MV; Kozhinov AN; Tsybin YO
    Anal Chem; 2014 Sep; 86(18):9020-8. PubMed ID: 25140615
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fine Structure in Isotopic Peak Distributions Measured Using Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: A Comparison between an Infinity ICR Cell and a Dynamically Harmonized ICR Cell.
    Xu J; Li M; Marzullo B; Wootton CA; Barrow MP; O'Connor PB
    J Am Soc Mass Spectrom; 2022 Aug; 33(8):1499-1509. PubMed ID: 35763614
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of Online Liquid Chromatography 7 T FT-ICR Mass Spectrometer Equipped with Quadrupolar Detection for Analysis of Natural Organic Matter.
    Kim D; Kim S; Son S; Jung MJ; Kim S
    Anal Chem; 2019 Jun; 91(12):7690-7697. PubMed ID: 31117404
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures.
    Smith DF; Podgorski DC; Rodgers RP; Blakney GT; Hendrickson CL
    Anal Chem; 2018 Feb; 90(3):2041-2047. PubMed ID: 29303558
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Online Coupling of Liquid Chromatography with Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at 21 T Provides Fast and Unique Insight into Crude Oil Composition.
    Rowland SM; Smith DF; Blakney GT; Corilo YE; Hendrickson CL; Rodgers RP
    Anal Chem; 2021 Oct; 93(41):13749-13754. PubMed ID: 34623794
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.
    Cho Y; Ahmed A; Islam A; Kim S
    Mass Spectrom Rev; 2015; 34(2):248-63. PubMed ID: 24942384
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pushing the analytical limits: new insights into complex mixtures using mass spectra segments of constant ultrahigh resolving power.
    Palacio Lozano DC; Gavard R; Arenas-Diaz JP; Thomas MJ; Stranz DD; Mejía-Ospino E; Guzman A; Spencer SEF; Rossell D; Barrow MP
    Chem Sci; 2019 Aug; 10(29):6966-6978. PubMed ID: 31588263
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Potential analytical applications of interfacing a GC to an FT-ICR MS: fingerprinting complex sample matrixes.
    Szulejko JE; Solouki T
    Anal Chem; 2002 Jul; 74(14):3434-42. PubMed ID: 12139051
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simultaneous molecular formula determinations of natural compounds in a plant extract using 15 T Fourier transform ion cyclotron resonance mass spectrometry.
    Park KH; Kim MS; Baek SJ; Bae IH; Seo SW; Kim J; Shin YK; Lee YM; Kim HS
    Plant Methods; 2013; 9():15. PubMed ID: 23721581
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Screening of synthetic PDE-5 inhibitors and their analogues as adulterants: analytical techniques and challenges.
    Patel DN; Li L; Kee CL; Ge X; Low MY; Koh HL
    J Pharm Biomed Anal; 2014 Jan; 87():176-90. PubMed ID: 23721687
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.