These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 38721036)

  • 21. Medic and Portable Pulse Oximeter Respiratory Rate Measurement Comparison to Waveform Capnography: A Prospective, Observational Study.
    Yi HJ; Jin LM; Long D; Carius BM; Ahern BJ
    Med J (Ft Sam Houst Tex); 2023; (Per 23-4/5/6):80-86. PubMed ID: 37042510
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Level of agreement between prehospital and emergency department vital signs in trauma patients.
    Dinh MM; Oliver M; Bein K; Muecke S; Carroll T; Veillard AS; Gabbe BJ; Ivers R
    Emerg Med Australas; 2013 Oct; 25(5):457-63. PubMed ID: 24099376
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Telemetry monitoring during transport of low-risk chest pain patients from the emergency department: is it necessary?
    Singer AJ; Visram F; Shembekar A; Khwaja M; Viccellio A
    Acad Emerg Med; 2005 Oct; 12(10):965-9. PubMed ID: 16204140
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Acoustic method respiratory rate monitoring is useful in patients under intravenous anesthesia.
    Ouchi K; Fujiwara S; Sugiyama K
    J Clin Monit Comput; 2017 Feb; 31(1):59-65. PubMed ID: 26759335
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Capnography for procedural sedation in the ED: a systematic review.
    Dewdney C; MacDougall M; Blackburn R; Lloyd G; Gray A
    Emerg Med J; 2017 Jul; 34(7):476-484. PubMed ID: 27565194
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The prevalence and diagnostic utility of systemic inflammatory response syndrome vital signs in a pediatric emergency department.
    Scott HF; Deakyne SJ; Woods JM; Bajaj L
    Acad Emerg Med; 2015 Apr; 22(4):381-9. PubMed ID: 25778743
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of respiratory rate monitoring using a microwave Doppler sensor mounted on the ceiling of an intensive care unit: a prospective observational study.
    Tanaka H; Yokose M; Takaki S; Mihara T; Saigusa Y; Goto T
    J Clin Monit Comput; 2022 Feb; 36(1):71-79. PubMed ID: 34191253
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Assessment of neonatal respiratory rate variability.
    Coleman J; Ginsburg AS; Macharia WM; Ochieng R; Chomba D; Zhou G; Dunsmuir D; Karlen W; Ansermino JM
    J Clin Monit Comput; 2022 Dec; 36(6):1869-1879. PubMed ID: 35332406
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Performance and usability of a new mobile application for measuring respiratory rate in young children with acute lower respiratory infections.
    Spurr R; Ng E; Onchiri FM; Rapha B; Nakatumba-Nabende J; Rosenfeld M; Najjingo I; Stout JW; Nantanda R; Ellington LE
    Pediatr Pulmonol; 2022 Dec; 57(12):3009-3016. PubMed ID: 35996862
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Consistency evaluation of target heart rate determined by anaerobic threshold and by resting heart rate in patients with coronary artery disease after percutaneous coronary intervention].
    Niu SP; Guo L; Guo DJ; Fan XM; Ding RJ
    Zhonghua Xin Xue Guan Bing Za Zhi; 2022 May; 50(5):480-485. PubMed ID: 35589597
    [No Abstract]   [Full Text] [Related]  

  • 31. Diagnostic utility of capnography in emergency department triage for screening acidemia: a pilot study.
    Peng P; Manini AF
    Int J Emerg Med; 2024 Apr; 17(1):57. PubMed ID: 38649817
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Validity of sidestream endtidal carbon dioxide measurement in critically ill, mechanically ventilated children.
    van der Heijden HH; Truin GJ; Verhaeg J; van der Pol P; Lemson J
    Paediatr Anaesth; 2016 Mar; 26(3):294-9. PubMed ID: 26714621
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Agreement between wireless and standard measurements of vital signs in acute exacerbation of chronic obstructive pulmonary disease: a clinical validation study.
    Elvekjaer M; Carlsson CJ; Rasmussen SM; Porsbjerg CM; Grønbæk KK; Haahr-Raunkjær C; Sørensen HBD; Aasvang EK; Meyhoff CS
    Physiol Meas; 2021 Jun; 42(5):. PubMed ID: 33984846
    [No Abstract]   [Full Text] [Related]  

  • 34. Capnography monitoring in procedural intravenous sedation: a systematic review and meta-analysis.
    Askar H; Misch J; Chen Z; Chadha S; Wang HL
    Clin Oral Investig; 2020 Nov; 24(11):3761-3770. PubMed ID: 32556657
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Accuracy evaluation of mainstream and sidestream end-tidal carbon dioxide monitoring during noninvasive ventilation: a randomized crossover trial (MASCAT-NIV trial).
    Sakuraya M; Douno E; Iwata W; Takaba A; Hadama K; Kawamura N; Maezawa T; Iwamoto K; Yoshino Y; Yoshida K
    J Intensive Care; 2022 Mar; 10(1):17. PubMed ID: 35303968
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A pilot study of respiratory rate derived from a wearable biosensor compared with capnography in emergency department patients.
    Li T; Divatia S; McKittrick J; Moss J; Hijnen NM; Becker LB
    Open Access Emerg Med; 2019; 11():103-108. PubMed ID: 31123424
    [No Abstract]   [Full Text] [Related]  

  • 37. Capnography monitoring in nonintubated patients with respiratory distress.
    Jabre P; Jacob L; Auger H; Jaulin C; Monribot M; Aurore A; Margenet A; Marty J; Combes X
    Am J Emerg Med; 2009 Nov; 27(9):1056-9. PubMed ID: 19931750
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Concordance between capnography and capnia in adults admitted for acute dyspnea in an ED.
    Delerme S; Freund Y; Renault R; Devilliers C; Castro S; Chopin S; Juillien G; Riou B; Ray P
    Am J Emerg Med; 2010 Jul; 28(6):711-4. PubMed ID: 20637388
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Continuous monitoring of vital signs with the Everion biosensor on the surgical ward: a clinical validation study.
    Haveman ME; van Melzen R; Schuurmann RCL; El Moumni M; Hermens HJ; Tabak M; de Vries JPM
    Expert Rev Med Devices; 2021 Dec; 18(sup1):145-152. PubMed ID: 34937478
    [TBL] [Abstract][Full Text] [Related]  

  • 40.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.