  • 1. Comparison of outcomes and required tools between transvenous extraction of pacemaker and implantable cardioverter defibrillator leads: Insight from single high-volume center experience.
    Hayashi K; Callahan T; Rickard J; Baranowski B; Martin DO; Nakhla S; Tabaja C; Paul A; Wilkoff BL
    J Cardiovasc Electrophysiol; 2024 Jul; 35(7):1382-1392. PubMed ID: 38725252
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.
    Brunner MP; Cronin EM; Jacob J; Duarte VE; Tarakji KG; Martin DO; Callahan T; Borek PP; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2013 Oct; 10(10):1444-50. PubMed ID: 23816440
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Extraction outcomes of implantable cardioverter-defibrillator leads vary by manufacturer and model family.
    Hayashi K; Callahan T; Rickard J; Younis A; Baranowski B; Martin D; Nakhla S; Tabaja C; Wilkoff BL
    Europace; 2023 Dec; 25(12):. PubMed ID: 38000893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre.
    Ząbek A; Boczar K; Ulman M; Holcman K; Kostkiewicz M; Pfitzner R; Dębski M; Musiał R; Lelakowski J; Małecka B
    Europace; 2023 Mar; 25(3):1100-1109. PubMed ID: 36660771
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions.
    Brunner MP; Cronin EM; Duarte VE; Yu C; Tarakji KG; Martin DO; Callahan T; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2014 May; 11(5):799-805. PubMed ID: 24444444
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transvenous lead extraction of implantable cardioverter-defibrillators: A comprehensive outcome-and risk factor analysis.
    Chung DU; Burger H; Kaiser L; Osswald B; Bärsch V; Nägele H; Knaut M; Reichenspurner H; Gessler N; Willems S; Butter C; Pecha S; Hakmi S;
    Pacing Clin Electrophysiol; 2023 Aug; 46(8):815-823. PubMed ID: 37461858
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evolution in transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using a mechanical dilator sheath.
    Oto A; Aytemir K; Canpolat U; Yorgun H; Şahiner L; Kaya EB; Kabakçi G; Tokgözoğlu L
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):834-40. PubMed ID: 22486778
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Initial experience of pacemaker and implantable cardioverter defibrillator lead extraction with the new GlideLight 80 Hz laser sheaths.
    Hakmi S; Pecha S; Sill B; Reiter B; Willems S; Aydin MA; Yildirim Y; Reichenspurner H; Treede H
    Interact Cardiovasc Thorac Surg; 2014 Jan; 18(1):56-60. PubMed ID: 24087832
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effectiveness and safety of transvenous extraction of single- versus dual-coil implantable cardioverter-defibrillator leads at single-center experience.
    Ząbek A; Boczar K; Dębski M; Ulman M; Pfitzner R; Musiał R; Lelakowski J; Małecka B
    Medicine (Baltimore); 2019 Jul; 98(30):e16548. PubMed ID: 31348275
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Outcomes of patients requiring emergent surgical or endovascular intervention for catastrophic complications during transvenous lead extraction.
    Brunner MP; Cronin EM; Wazni O; Baranowski B; Saliba WI; Sabik JF; Lindsay BD; Wilkoff BL; Tarakji KG
    Heart Rhythm; 2014 Mar; 11(3):419-25. PubMed ID: 24315967
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Is the transvenous extraction of cardioverter-defibrillator leads more hazardous than that of pacemaker leads?
    Małecka B; Kutarski A; Grabowski M
    Kardiol Pol; 2010 Aug; 68(8):884-90. PubMed ID: 20730717
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Outcome of transvenous lead extraction of leads older than 20 years.
    Issa ZF
    J Cardiovasc Electrophysiol; 2021 Nov; 32(11):3042-3048. PubMed ID: 34453369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transvenous lead extraction in patients with prior extraction procedures: Procedural profiles and outcomes.
    Hutt E; Diab M; Wazni OM; Kaur S; Tarakji KG; Saliba WI; Kanj M; Cantillon D; Rickard J; Varma N; Callahan T; Martin DO; Niebauer M; Dresing T; Chung M; Wilkoff BL; Hussein AA
    Heart Rhythm; 2020 Nov; 17(11):1904-1908. PubMed ID: 32512177
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transvenous extraction of permanent pacemaker and defibrillator leads: Reduced procedural complexity and higher procedural success rates in patients with infective versus noninfective indications.
    Archontakis S; Pirounaki M; Aznaouridis K; Karageorgopoulos D; Sideris K; Tolios P; Triantafyllou K; Gatzoulis K; Tousoulis D; Sideris S
    J Cardiovasc Electrophysiol; 2021 Feb; 32(2):491-499. PubMed ID: 33345428
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Safety and effectiveness of transvenous extraction of pacemaker and implantable cardioverter-defibrillator leads in patients under or over 80 years of age.
    Kempa M; Budrejko S; Piepiorka M; Rogowski J; Raczak G; Kozłowski D
    Kardiol Pol; 2013; 71(2):130-5. PubMed ID: 23575705
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extraction of old pacemaker or cardioverter-defibrillator leads by laser sheath versus femoral approach.
    Bordachar P; Defaye P; Peyrouse E; Boveda S; Mokrani B; Marquié C; Barandon L; Fossaert EM; Garrigue S; Reuter S; Laborderie J; Marijon E; Deharo JC; Jacon P; Kacet S; Ploux S; Deplagne A; Haissaguerre M; Clementy J; Ritter P; Klug D
    Circ Arrhythm Electrophysiol; 2010 Aug; 3(4):319-23. PubMed ID: 20562442
    [TBL] [Abstract][Full Text] [Related]  

  • 17. How adequate are the current methods of lead extraction? A review of the efficiency and safety of transvenous lead extraction methods.
    Buiten MS; van der Heijden AC; Schalij MJ; van Erven L
    Europace; 2015 May; 17(5):689-700. PubMed ID: 25687745
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Procedural outcomes associated with transvenous lead extraction in patients with abandoned leads: an ESC-EHRA ELECTRa (European Lead Extraction ConTRolled) Registry Sub-Analysis.
    Segreti L; Rinaldi CA; Claridge S; Svendsen JH; Blomstrom-Lundqvist C; Auricchio A; Butter C; Dagres N; Deharo JC; Maggioni AP; Kutarski A; Kennergren C; Laroche C; Kempa M; Magnani A; Casteigt B; Bongiorni MG;
    Europace; 2019 Apr; 21(4):645-654. PubMed ID: 30624715
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction.
    Aytemir K; Yorgun H; Canpolat U; Şahiner ML; Kaya EB; Evranos B; Özer N
    Europace; 2016 Jul; 18(7):1043-8. PubMed ID: 26467403
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Outcomes of Transvenous Extraction of Leads Older Than 20 and 30 Years-A Large Cohort Study.
    Kutarski A; Głowniak A; Kosior J; Jacheć W; Nowosielecka D; Czajkowski M; Polewczyk A
    Int J Environ Res Public Health; 2022 Oct; 19(21):. PubMed ID: 36361063
    [TBL] [Abstract][Full Text] [Related]  