BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 38725401)

  • 1. Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study.
    Okamoto T; Sasaki T; Takeda T; Hirai T; Ishitsuka T; Yamada M; Nakagawa H; Mie T; Furukawa T; Kasuga A; Ozaka M; Sasahira N
    Clin Endosc; 2024 May; ():. PubMed ID: 38725401
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Endoscopic ultrasonography-guided hepaticogastrostomy using a novel laser-cut type partially covered self-expandable metal stent (with video).
    Ogura T; Kitano M; Okuda A; Itonaga M; Ueno S; Yamashita Y; Nishioka N; Ashida R; Miyano A; Higuchi K
    Dig Endosc; 2021 Nov; 33(7):1188-1193. PubMed ID: 34318527
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Long-term outcomes of endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction.
    Hedjoudje A; Pokossy Epée J; Perez-Cuadrado-Robles E; Alric H; Rivallin P; Vuitton L; Koch S; Prat F
    United European Gastroenterol J; 2024 Apr; ():. PubMed ID: 38578654
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term outcomes of a long, partially covered metal stent for EUS-guided hepaticogastrostomy in patients with malignant biliary obstruction (with video).
    Nakai Y; Sato T; Hakuta R; Ishigaki K; Saito K; Saito T; Takahara N; Hamada T; Mizuno S; Kogure H; Nogchi K; Ito Y; Isayama H; Koike K
    Gastrointest Endosc; 2020 Sep; 92(3):623-631.e1. PubMed ID: 32278705
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Usefulness of the laser-cut, fully covered, self-expandable metallic stent for endoscopic ultrasound-guided hepaticogastrostomy.
    Harai S; Hijioka S; Nagashio Y; Ohba A; Maruki Y; Sone M; Saito Y; Okusaka T; Fukasawa M; Enomoto N
    J Hepatobiliary Pancreat Sci; 2022 Sep; 29(9):1035-1043. PubMed ID: 35561015
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preliminary feasibility study of a new partially covered self-expandable metal stent with an anchoring flange for EUS-guided hepaticogastrostomy (with videos).
    Shin IS; Moon JH; Lee YN; Myeong JH; Lee TH; Yang JK; Cho YD; Park SH; Giovannini M
    Gastrointest Endosc; 2023 Nov; 98(5):848-856. PubMed ID: 37473968
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endoscopic ultrasound-guided hepaticogastrostomy versus hepaticogastrostomy with antegrade stenting for malignant distal biliary obstruction.
    Ishiwatari H; Ishikawa K; Niiya F; Matsubayashi H; Kishida Y; Yoshida M; Kawata N; Imai K; Hotta K; Ono H
    J Hepatobiliary Pancreat Sci; 2022 Jun; 29(6):703-712. PubMed ID: 35094496
    [TBL] [Abstract][Full Text] [Related]  

  • 8. EUS-guided hepaticogastrostomy versus EUS-guided hepaticogastrostomy with antegrade stent placement in patients with unresectable malignant distal biliary obstruction: a propensity score-matched case-control study.
    Ishiwatari H; Ogura T; Hijioka S; Iwashita T; Matsubara S; Ishikawa K; Niiya F; Sato J; Okuda A; Ueno S; Nagashio Y; Maruki Y; Uemura S; Notsu A
    Gastrointest Endosc; 2024 Jul; 100(1):66-75. PubMed ID: 38382887
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safety and effectiveness of a long, partially covered metal stent for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction.
    Nakai Y; Isayama H; Yamamoto N; Matsubara S; Ito Y; Sasahira N; Hakuta R; Umefune G; Takahara N; Hamada T; Mizuno S; Kogure H; Tada M; Koike K
    Endoscopy; 2016 Dec; 48(12):1125-1128. PubMed ID: 27716860
    [No Abstract]   [Full Text] [Related]  

  • 10. Propensity score matching analysis for clinical impact of braided-type versus laser-cut-type covered self-expandable metal stents for endoscopic ultrasound-guided hepaticogastrostomy.
    Tomita M; Ogura T; Hakoda A; Ueno S; Okuda A; Nishioka N; Yamamoto Y; Nishikawa H
    Hepatobiliary Pancreat Dis Int; 2024 Apr; 23(2):181-185. PubMed ID: 37634988
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction.
    Shibuki T; Okumura K; Sekine M; Kobori I; Miyagaki A; Sasaki Y; Takano Y; Hashimoto Y
    Clin Endosc; 2023 Nov; 56(6):802-811. PubMed ID: 37032113
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term outcomes of endoscopic double stenting using an anti-reflux metal stent for combined malignant biliary and duodenal obstruction.
    Sasaki T; Takeda T; Yamada Y; Okamoto T; Mori C; Mie T; Kasuga A; Matsuyama M; Ozaka M; Sasahira N
    J Hepatobiliary Pancreat Sci; 2023 Jan; 30(1):144-152. PubMed ID: 35583159
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Utility of Endoscopic Ultrasound-Guided Hepaticogastrostomy with Antegrade Stenting for Malignant Biliary Obstruction after Failed Endoscopic Retrograde Cholangiopancreatography.
    Imai H; Takenaka M; Omoto S; Kamata K; Miyata T; Minaga K; Yamao K; Sakurai T; Nishida N; Watanabe T; Kitano M; Kudo M
    Oncology; 2017; 93 Suppl 1():69-75. PubMed ID: 29258066
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of the 6-mm fully covered self-expandable metal stent during endoscopic ultrasound-guided hepaticogastrostomy as a primary biliary drainage for the cases estimated difficult endoscopic retrograde cholangiopancreatography: A prospective clinical study.
    Okuno N; Hara K; Mizuno N; Kuwahara T; Iwaya H; Ito A; Kuraoka N; Matsumoto S; Polmanee P; Niwa Y
    J Gastroenterol Hepatol; 2018 Jul; 33(7):1413-1421. PubMed ID: 29424011
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A pilot study of Spring Stopper Stents: Novel partially covered self-expandable metallic stents with anti-migration properties for EUS-guided hepaticogastrostomy.
    Ishii S; Isayama H; Sasahira N; Matsubara S; Nakai Y; Fujisawa T; Tomishima K; Sasaki T; Ishigaki K; Kogure H; Okamoto T; Otsuka T; Takasaki Y; Suzuki A
    Endosc Ultrasound; 2023; 12(2):266-272. PubMed ID: 37148139
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of a dedicated plastic stent in endoscopic ultrasound-guided hepaticogastrostomy during the learning curve: cumulative multi-center experience.
    Kitagawa K; Mitoro A; Minami R; Nagamatsu S; Ozutsumi T; Fujinaga Y; Nishimura N; Sawada Y; Namisaki T; Akahane T; Kaji K; Tomooka F; Asada S; Kaneko M; Yoshiji H
    Scand J Gastroenterol; 2023 Mar; 58(3):296-303. PubMed ID: 36073949
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multicenter retrospective study of endoscopic ultrasound-guided biliary drainage for malignant biliary obstruction in Japan.
    Kawakubo K; Isayama H; Kato H; Itoi T; Kawakami H; Hanada K; Ishiwatari H; Yasuda I; Kawamoto H; Itokawa F; Kuwatani M; Iiboshi T; Hayashi T; Doi S; Nakai Y
    J Hepatobiliary Pancreat Sci; 2014 May; 21(5):328-34. PubMed ID: 24026963
    [TBL] [Abstract][Full Text] [Related]  

  • 18. EUS-Guided Antegrade Biliary Stenting Using a Novel Fully Covered Metal Stent (with Video).
    Yamada M; Ogura T; Kamiyama R; Miyano A; Nishioka N; Yamada T; Higuchi K
    J Gastrointest Surg; 2019 Jan; 23(1):192-198. PubMed ID: 30128830
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of recurrent biliary obstruction with the use of metal and plastic stents in EUS-guided biliary drainage: A propensity score-matched analysis.
    Hashimoto S; Iwashita Y; Taguchi H; Tanoue S; Ohi T; Shibata R; Haraguchi T; Kamikihara Y; Toyodome K; Kojima I; Araki N; Tsuneyoshi K; Nakamura Y; Fujita T; Hinokuchi M; Iwaya H; Arima S; Sasaki F; Kanmura S; Ido A
    Endosc Ultrasound; 2023; 12(1):64-73. PubMed ID: 36510868
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel partially covered metallic stent with a 20-mm long distal bare portion for EUS-guided hepaticogastrostomy.
    Asai S; Takeshita K; Ichinona T; Akamine E; Fujimoto N
    VideoGIE; 2021 Jul; 6(7):322-324. PubMed ID: 34278097
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.