169 related articles for article (PubMed ID: 387295)
1. Assay of theophylline: comparison of EMIT on the ABA-100 to HPLC, GLC and UV procedures, with detailed evaluation of interferences.
Weidner N; McDonald JM; Tieber VL; Smith CH; Kessler G; Ladenson JH; Dietzler DN
Clin Chim Acta; 1979 Sep; 97(1):9-17. PubMed ID: 387295
[TBL] [Abstract][Full Text] [Related]
2. A clinically applicable high-pressure liquid chromatographic method for measurement of serum theophylline, with detailed evaluation of interferences.
Weidner N; Dietzler DN; Ladenson JH; Kessler G; Larson L; Smith CH; James T; McDonald JM
Am J Clin Pathol; 1980 Jan; 73(1):79-86. PubMed ID: 7352428
[TBL] [Abstract][Full Text] [Related]
3. Accuracy and precision of gas-liquid chromatographic, high-pressure liquid chromatographic, and enzyme immunoassay techniques for the measurement of theophylline concentrations in serum: a comparison based on external quality assurance measurements.
Wilson JF; Marshall RW; Williams J; Richens A
Ther Drug Monit; 1984; 6(2):243-50. PubMed ID: 6377601
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the Du Pont Theophylline Assay adapted to a centrifugal analyzer.
Boeckx RL; Munson ST
Ther Drug Monit; 1985; 7(1):95-100. PubMed ID: 3887672
[TBL] [Abstract][Full Text] [Related]
5. Results of a quality control scheme for the assay of theophylline in serum.
Boobis S; Persaud N; Richens A
Ther Drug Monit; 1979; 1(2):257-63. PubMed ID: 400263
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of a rapid high-performance liquid chromatographic method for plasma theophylline analysis and its use in therapeutic drug monitoring.
Starkey BJ; Mould GP
Ther Drug Monit; 1984; 6(3):322-7. PubMed ID: 6390795
[TBL] [Abstract][Full Text] [Related]
7. Comparison of a high performance liquid chromatographic and an enzyme immunoassay technique for quantitation of theophylline in serum.
Boeckx RL; Frith EM; Simons FE
Ther Drug Monit; 1979; 1(1):65-73. PubMed ID: 399811
[TBL] [Abstract][Full Text] [Related]
8. Theophylline estimation-a comparative evaluation of a gas chromatographic method and a high-performance liquid chromatographic method.
Naish PJ; Chambers RE; Cooke M
Ann Clin Biochem; 1979 Sep; 16(5):254-8. PubMed ID: 517984
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of caffeine plasma levels by an automated enzyme immunoassay (EMIT) in comparison with a high-performance liquid chromatographic method.
Zysset T; Wahlländer A; Preisig R
Ther Drug Monit; 1984; 6(3):348-54. PubMed ID: 6390797
[TBL] [Abstract][Full Text] [Related]
10. Comparison of three assay procedures for theophylline determination.
Kampa IS; Dunikoski LK; Jarzabek JI; Grubesich D
Ther Drug Monit; 1979; 1(2):249-56. PubMed ID: 400262
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of tricyclic antidepressant plasma levels by an automated enzyme immunoassay (EMIT) in comparison to a high-performance liquid chromatographic method.
Fazio A; Artesi C; Lorefice C; Oteri G; Romano F; Russo M; Spina E; Trio R; Pisani F
Ther Drug Monit; 1988; 10(3):333-9. PubMed ID: 3051537
[TBL] [Abstract][Full Text] [Related]
12. Monitoring of serum theophylline concentrations by a fully mechanized enzyme immunoassay (EMIT).
Oellerich M; Sybrecht GW; Haeckel R
J Clin Chem Clin Biochem; 1979 May; 17(5):299-302. PubMed ID: 381565
[TBL] [Abstract][Full Text] [Related]
13. Washington University Case Conference: Theophylline toxicity.
Clin Chem; 1978 Sep; 24(9):1603-8. PubMed ID: 357040
[TBL] [Abstract][Full Text] [Related]
14. High-pressure liquid chromatographic and spectrophotometric assays for theophylline in biological fluids.
Jusko WJ; Poliszczuk A
Am J Hosp Pharm; 1976 Nov; 33(11):1193-6. PubMed ID: 998637
[TBL] [Abstract][Full Text] [Related]
15. Non-extraction HPLC method for the simultaneous measurement of theophylline and caffeine in human serum.
Rainbow SJ; Dawson CM; Tickner TR
Ann Clin Biochem; 1989 Nov; 26 ( Pt 6)():527-32. PubMed ID: 2619232
[TBL] [Abstract][Full Text] [Related]
16. Comparison of serum theophylline concentrations measured by high pressure liquid chromatography and quantitative enzyme-multiplied immunoassay technique.
Sheen AE; Sly RM; Hite S; Giblin VR; Hebert M
Ann Allergy; 1979 Feb; 42(2):77-9. PubMed ID: 369408
[TBL] [Abstract][Full Text] [Related]
17. Comparison of homogeneous enzyme immunoassay and high-pressure liquid chromatography for the determination of theophylline concentration in serum.
Koup JR; Brodsky B
Am Rev Respir Dis; 1978 Jun; 117(6):1135-8. PubMed ID: 352208
[TBL] [Abstract][Full Text] [Related]
18. [Determination of theophylline, phenobarbital and valproic acid by chromatographic and immunologic technics. Comparison of methods].
Vinçon G; Demotes-Mainard F; Bistue C; Jarry C; Brachet-Liermain A; Albin H
Ann Biol Clin (Paris); 1984; 42(6):427-32. PubMed ID: 6442547
[TBL] [Abstract][Full Text] [Related]
19. A single liquid-chromatographic procedure for therapeutic monitoring of theophylline, acetaminophen, or ethosuximide.
Quattrone AJ; Putnam RS
Clin Chem; 1981 Jan; 27(1):129-32. PubMed ID: 7004665
[TBL] [Abstract][Full Text] [Related]
20. No effect of influenza vaccination on theophylline pharmacokinetics as studied by ultraviolet spectrophotometry, HPLC, and EMIT assay methods.
Jonkman JH; Wymenga AS; de Zeeuw RA; van der Boon WV; Beugelink JK; Oosterhuis B; Jedema JN
Ther Drug Monit; 1988; 10(3):345-8. PubMed ID: 3051538
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]