These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 38729771)

  • 1. Glucose levels measured with continuous glucose monitoring in uncomplicated pregnancies.
    Carlson AL; Beck RW; Li Z; Norton E; Bergenstal RM; Johnson M; Dunnigan S; Banfield M; Krumwiede KJ; Sibayan JR; Calhoun P; Durnwald C
    BMJ Open Diabetes Res Care; 2024 May; 12(3):. PubMed ID: 38729771
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Feasibility Study of Paired Continuous Glucose Monitoring Intrapartum and in the Newborn in Pregnancies Complicated by Type 1 Diabetes.
    Stewart ZA; Thomson L; Murphy HR; Beardsall K
    Diabetes Technol Ther; 2019 Jan; 21(1):20-27. PubMed ID: 30620640
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous Glucose Monitoring Profiles in Pregnancies With and Without Gestational Diabetes Mellitus.
    Durnwald C; Beck RW; Li Z; Norton E; Bergenstal RM; Johnson M; Dunnigan S; Banfield M; Krumwiede K; Sibayan J; Calhoun P; Carlson AL
    Diabetes Care; 2024 Aug; 47(8):1333-1341. PubMed ID: 38701400
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of oral glucose tolerance test and ambulatory glycaemic profiles in pregnant women in Uganda with gestational diabetes using the FreeStyle Libre flash glucose monitoring system.
    Milln JM; Walugembe E; Ssentayi S; Nkabura H; Jones AG; Nyirenda MJ
    BMC Pregnancy Childbirth; 2020 Oct; 20(1):635. PubMed ID: 33076849
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of Reference Metrics for Continuous Glucose Monitoring in Persons Without Diabetes and Prediabetes.
    Sofizadeh S; Pehrsson A; Ólafsdóttir AF; Lind M
    J Diabetes Sci Technol; 2022 Mar; 16(2):373-382. PubMed ID: 33100059
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous glucose monitoring results in lower HbA
    Paramasivam SS; Chinna K; Singh AKK; Ratnasingam J; Ibrahim L; Lim LL; Tan ATB; Chan SP; Tan PC; Omar SZ; Bilous RW; Vethakkan SR
    Diabet Med; 2018 Aug; 35(8):1118-1129. PubMed ID: 29663517
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Techniques of monitoring blood glucose during pregnancy for women with pre-existing diabetes.
    Moy FM; Ray A; Buckley BS; West HM
    Cochrane Database Syst Rev; 2017 Jun; 6(6):CD009613. PubMed ID: 28602020
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous Glucose Monitoring in Pregnancy: Importance of Analyzing Temporal Profiles to Understand Clinical Outcomes.
    Scott EM; Feig DS; Murphy HR; Law GR;
    Diabetes Care; 2020 Jun; 43(6):1178-1184. PubMed ID: 32209645
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Suboptimal Nocturnal Glucose Control Is Associated With Large for Gestational Age in Treated Gestational Diabetes Mellitus.
    Law GR; Alnaji A; Alrefaii L; Endersby D; Cartland SJ; Gilbey SG; Jennings PE; Murphy HR; Scott EM
    Diabetes Care; 2019 May; 42(5):810-815. PubMed ID: 30765428
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Continuous Glucose Monitoring Profiles in Healthy Nondiabetic Participants: A Multicenter Prospective Study.
    Shah VN; DuBose SN; Li Z; Beck RW; Peters AL; Weinstock RS; Kruger D; Tansey M; Sparling D; Woerner S; Vendrame F; Bergenstal R; Tamborlane WV; Watson SE; Sherr J
    J Clin Endocrinol Metab; 2019 Oct; 104(10):4356-4364. PubMed ID: 31127824
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Glycaemia in low-premixed insulin analogue type 2 diabetes patients in a real-world setting: are the CGM targets met?
    Krajnc M; Kravos Tramšek NA
    Eur J Med Res; 2023 Mar; 28(1):111. PubMed ID: 36882852
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metformin in women with type 2 diabetes in pregnancy (MiTy): a multicentre, international, randomised, placebo-controlled trial.
    Feig DS; Donovan LE; Zinman B; Sanchez JJ; Asztalos E; Ryan EA; Fantus IG; Hutton E; Armson AB; Lipscombe LL; Simmons D; Barrett JFR; Karanicolas PJ; Tobin S; McIntyre HD; Tian SY; Tomlinson G; Murphy KE;
    Lancet Diabetes Endocrinol; 2020 Oct; 8(10):834-844. PubMed ID: 32946820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Clinical use of continuous glucose monitoring system in gestational diabetes mellitus and type 2 diabetes complicated with pregnancy].
    Song Y; Yang H
    Zhonghua Fu Chan Ke Za Zhi; 2014 Aug; 49(8):579-83. PubMed ID: 25354857
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Introductory experience with the continuous glucose monitoring system (CGMS; Medtronic Minimed) in detecting hyperglycemia by comparing the self-monitoring of blood glucose (SMBG) in non-pregnant women and in pregnant women with impaired glucose tolerance and gestational diabetes.
    Bühling KJ; Kurzidim B; Wolf C; Wohlfarth K; Mahmoudi M; Wäscher C; Siebert G; Dudenhausen JW
    Exp Clin Endocrinol Diabetes; 2004 Nov; 112(10):556-60. PubMed ID: 15578329
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of the Dexcom G6 Continuous Glucose Monitoring System in Pregnant Women with Diabetes.
    Castorino K; Polsky S; O'Malley G; Levister C; Nelson K; Farfan C; Brackett S; Puhr S; Levy CJ
    Diabetes Technol Ther; 2020 Dec; 22(12):943-947. PubMed ID: 32324061
    [No Abstract]   [Full Text] [Related]  

  • 16. The Association Between HbA
    Seyed Ahmadi S; Westman K; Pivodic A; Ólafsdóttir AF; Dahlqvist S; Hirsch IB; Hellman J; Ekelund M; Heise T; Polonsky W; Wijkman M; Schwarcz E; Lind M
    Diabetes Care; 2020 Sep; 43(9):2017-2024. PubMed ID: 32641374
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessing the Accuracy of Continuous Glucose Monitoring (CGM) Calibrated With Capillary Values Using Capillary or Venous Glucose Levels as a Reference.
    Andelin M; Kropff J; Matuleviciene V; Joseph JI; Attvall S; Theodorsson E; Hirsch IB; Imberg H; Dahlqvist S; Klonoff D; Haraldsson B; DeVries JH; Lind M
    J Diabetes Sci Technol; 2016 Jul; 10(4):876-84. PubMed ID: 26810924
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of the Dexcom G7 Continuous Glucose Monitoring System in Pregnant Women with Diabetes.
    Polsky S; Valent AM; Isganaitis E; Castorino K; O'Malley G; Beck SE; Gao P; Laffel LM; Brown FM; Levy CJ
    Diabetes Technol Ther; 2024 May; 26(5):307-312. PubMed ID: 38315503
    [No Abstract]   [Full Text] [Related]  

  • 19. Achieving the HbA1c Target Requires Longer Time in Range in Pregnant Women With Type 1 Diabetes.
    Ling P; Yang D; Gu N; Xiao X; Lu J; Liu F; Zhou Z; Huang Q; Zhao J; Zhang M; Hu J; Luo S; Weng J; Yan J; Zheng X
    J Clin Endocrinol Metab; 2021 Oct; 106(11):e4309-e4317. PubMed ID: 34244734
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of initiating use of an insulin pump in adults with type 1 diabetes using multiple daily insulin injections and continuous glucose monitoring (DIAMOND): a multicentre, randomised controlled trial.
    Beck RW; Riddlesworth TD; Ruedy KJ; Kollman C; Ahmann AJ; Bergenstal RM; Bhargava A; Bode BW; Haller S; Kruger DF; McGill JB; Polonsky W; Price D; Toschi E;
    Lancet Diabetes Endocrinol; 2017 Sep; 5(9):700-708. PubMed ID: 28711468
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.