133 related articles for article (PubMed ID: 38737001)
1. Intramural hematoma extending from a dissection within an implanted stent: a case report treated with fenestration using a cutting balloon.
Okura T; Okabe T; Isomura N; Ochiai M
Eur Heart J Case Rep; 2024 May; 8(5):ytae223. PubMed ID: 38737001
[TBL] [Abstract][Full Text] [Related]
2. Fenestration Using a Novel Cutting Balloon for Acute Vessel Occlusion Secondary to Intramural Hematoma Following Stent Implantation.
Miura Y; Koyama K; Kongoji K; Soejima K
Cardiovasc Revasc Med; 2022 Jul; 40S():239-242. PubMed ID: 34799290
[TBL] [Abstract][Full Text] [Related]
3. Conservative management of severe coronary artery hematoma and dissection following stent implantation.
Yamamoto K; Sakakura K; Momomura SI; Fujita H
Cardiovasc Revasc Med; 2019 Apr; 20(4):347-350. PubMed ID: 29793897
[TBL] [Abstract][Full Text] [Related]
4. Balloon rupture during coronary angioplasty causing dissection and intramural hematoma of the coronary artery; a case report.
Katayama T; Sakoda N; Yamamoto F; Ishizaki M; Iwasaki Y
J Cardiol Cases; 2010 Feb; 1(1):e17-e20. PubMed ID: 30615766
[TBL] [Abstract][Full Text] [Related]
5. Successful treatment of a spontaneous right coronary artery dissection with a 4-mm diameter cutting balloon: a case report.
Sharma H; Vetrugno V; Khan SQ
Eur Heart J Case Rep; 2019 Dec; 3(4):1-6. PubMed ID: 31912001
[TBL] [Abstract][Full Text] [Related]
6. Intravascular ultrasound-guided treatment for simultaneous ostial left main intramural hematoma and anomalous right aortocoronary dissection.
Chong SZ; Fang HY; Fang CY
Int J Cardiovasc Imaging; 2022 Feb; 38(2):485-487. PubMed ID: 34467428
[TBL] [Abstract][Full Text] [Related]
7. Intravascular ultrasound-guided troubleshooting in a large hematoma treated with fenestration using a cutting balloon.
Noh HJ; Choi JH; Song YB; Jo HC; Yang JH; Kim SM; Lee HJ; Choi JH; Choi SH; Hahn JY; Choi SH; Gwon HC
Korean Circ J; 2009 Apr; 39(4):171-4. PubMed ID: 19949608
[TBL] [Abstract][Full Text] [Related]
8. Fenestration using a scoring balloon Scoreflex® as troubleshooting for acute vessel closure due to intramural hematoma complication in percutaneous coronary intervention.
Okuya Y; Fukushima K; Hori Y; Murayama T; Komiyama N
Cardiovasc Interv Ther; 2015 Jul; 30(3):311-4. PubMed ID: 25179775
[TBL] [Abstract][Full Text] [Related]
9. Intravascular ultrasound assessment of the incidence and predictors of edge dissections after drug-eluting stent implantation.
Liu X; Tsujita K; Maehara A; Mintz GS; Weisz G; Dangas GD; Lansky AJ; Kreps EM; Rabbani LE; Collins M; Stone GW; Moses JW; Mehran R; Leon MB
JACC Cardiovasc Interv; 2009 Oct; 2(10):997-1004. PubMed ID: 19850262
[TBL] [Abstract][Full Text] [Related]
10. Extensive intramural hematoma as the cause of failed coronary angioplasty: diagnosis by intravascular ultrasound and treatment by stent implantation.
Werner GS; Figulla HR; Grosse W; Kreuzer H
Cathet Cardiovasc Diagn; 1995 Oct; 36(2):173-8. PubMed ID: 8829841
[TBL] [Abstract][Full Text] [Related]
11. Persistent malapposition after implantation of sirolimus-eluting stent into intramural coronary hematoma: optical coherence tomography observations.
Sawada T; Shite J; Shinke T; Watanabe S; Otake H; Matsumoto D; Imuro Y; Ogasawara D; Paredes OL; Yokoyama M
Circ J; 2006 Nov; 70(11):1515-9. PubMed ID: 17062980
[TBL] [Abstract][Full Text] [Related]
12. Intravascular ultrasound to guide percutaneous coronary interventions: an evidence-based analysis.
Medical Advisory Secretariat
Ont Health Technol Assess Ser; 2006; 6(12):1-97. PubMed ID: 23074482
[TBL] [Abstract][Full Text] [Related]
13. Usefulness of Cutting Balloon Angioplasty Prior to Stenting with Intravascular Ultrasound Imaging Guidance for Spontaneous Multi-vessel Coronary Artery Dissection Including the Left Main Coronary Artery.
Noguchi M; Obunai K; Fukui Y; Okumura H; Watanabe H
Intern Med; 2018 Jul; 57(13):1867-1871. PubMed ID: 29434132
[TBL] [Abstract][Full Text] [Related]
14. Coronary artery intramural hematoma, a rare complication of percutaneous coronary intervention.
Hussain B; Bhavsar D; Dhulipala V
Radiol Case Rep; 2022 Oct; 17(10):3770-3773. PubMed ID: 35965935
[TBL] [Abstract][Full Text] [Related]
15. Prevalence, Features, and Prognostic Importance of Edge Dissection After Drug-Eluting Stent Implantation: An ADAPT-DES Intravascular Ultrasound Substudy.
Kobayashi N; Mintz GS; Witzenbichler B; Metzger DC; Rinaldi MJ; Duffy PL; Weisz G; Stuckey TD; Brodie BR; Parvataneni R; Kirtane AJ; Stone GW; Maehara A
Circ Cardiovasc Interv; 2016 Jul; 9(7):e003553. PubMed ID: 27402854
[TBL] [Abstract][Full Text] [Related]
16. Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study.
Rahman S; Leesar T; Cilingiroglu M; Effat M; Arif I; Helmy T; Leesar MA
JACC Cardiovasc Interv; 2013 Sep; 6(9):923-31. PubMed ID: 23954062
[TBL] [Abstract][Full Text] [Related]
17. Intravascular ultrasound system-guided bail-out stent implantation for iatrogenic aortocoronary dissection: a case report.
Fukui T; Ogasawara N
Eur Heart J Case Rep; 2023 Aug; 7(8):ytad332. PubMed ID: 37547366
[TBL] [Abstract][Full Text] [Related]
18. An analysis of published cases of cutting balloon use in spontaneous coronary artery dissection.
Maričić B; Perišić Z; Kostić T; Božinović N; Petrović M; Čanković M; Mehmedbegović Z; Juričić S; Vasilev V; Dakić S; Perišić J; Milošević J; Bojanović M; Nikolić M; Maričić T; Apostolović S
Front Cardiovasc Med; 2023; 10():1270530. PubMed ID: 38028445
[TBL] [Abstract][Full Text] [Related]
19. Coronary Artery Occlusion Caused by Intramural Hematoma Due to In-Stent Dissection.
Ueki Y; Räber L; Kavaliauskaite R; Otsuka T; Siontis GCM
JACC Case Rep; 2020 May; 2(5):707-708. PubMed ID: 34317330
[TBL] [Abstract][Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
[Next] [New Search]