121 related articles for article (PubMed ID: 38742468)
1. A numerical investigation for the development of functionally graded Ti/HA tibial implant for total ankle replacement: Influence of material gradation law and volume fraction index.
Jyoti ; Ghosh R
J Biomed Mater Res B Appl Biomater; 2024 May; 112(5):e35417. PubMed ID: 38742468
[TBL] [Abstract][Full Text] [Related]
2. Printable functionally graded tibial implant for TAR: FE study comparing implant materials, FGM properties, and implant designs.
Jyoti ; Ghosh R
Comput Biol Med; 2024 Jul; 177():108645. PubMed ID: 38796883
[TBL] [Abstract][Full Text] [Related]
3. A combined FE-hybrid MCDM framework for improving the performance of the conical stem tibial design for TAR with the addition of pegs.
Jyoti ; Ghosh R
Comput Methods Programs Biomed; 2023 Jul; 237():107574. PubMed ID: 37148636
[TBL] [Abstract][Full Text] [Related]
4. Effects of implant orientation and implant material on tibia bone strain, implant-bone micromotion, contact pressure, and wear depth due to total ankle replacement.
Mondal S; Ghosh R
Proc Inst Mech Eng H; 2019 Mar; 233(3):318-331. PubMed ID: 30663509
[TBL] [Abstract][Full Text] [Related]
5. The role of the depth of resection of the distal tibia on biomechanical performance of the tibial component for TAR: A finite element analysis with three implant designs.
Jyoti ; Ghosh R
Med Eng Phys; 2023 Sep; 119():104034. PubMed ID: 37634911
[TBL] [Abstract][Full Text] [Related]
6. In Vivo and In Vitro Analyses of Titanium-Hydroxyapatite Functionally Graded Material for Dental Implants.
Wang X; Wan C; Feng X; Zhao F; Wang H
Biomed Res Int; 2021; 2021():8859945. PubMed ID: 34036104
[TBL] [Abstract][Full Text] [Related]
7. Biomechanical analysis of three popular tibial designs for TAR with different implant-bone interfacial conditions and bone qualities: A finite element study.
Jyoti ; Mondal S; Ghosh R
Med Eng Phys; 2022 Jun; 104():103812. PubMed ID: 35641078
[TBL] [Abstract][Full Text] [Related]
8. Influence of design features of tibial stems in total knee arthroplasty on tibial bone remodeling behaviors.
Jia Z; Gong H; Hu S; Fang J; Fan R
Med Eng Phys; 2017 Oct; 48():103-113. PubMed ID: 28764879
[TBL] [Abstract][Full Text] [Related]
9. Evaluating the effect of functionally graded materials on bone remodeling around dental implants.
Rajaeirad M; Fakharifar A; Posti MHZ; Khorsandi M; Watts DC; Elraggal A; Ouldyerou A; Merdji A; Roy S
Dent Mater; 2024 May; 40(5):858-868. PubMed ID: 38616152
[TBL] [Abstract][Full Text] [Related]
10. Finite element stress analysis of the bearing component and bone resected surfaces for total ankle replacement with different implant material combinations.
Yu J; Zhao D; Chen WM; Chu P; Wang S; Zhang C; Huang J; Wang X; Ma X
BMC Musculoskelet Disord; 2022 Jan; 23(1):70. PubMed ID: 35045842
[TBL] [Abstract][Full Text] [Related]
11. Finite-element analysis of the influence of tibial implant fixation design of total ankle replacement on bone-implant interfacial biomechanical performance.
Yu J; Zhang C; Chen WM; Zhao D; Chu P; Wang S; Huang J; Wang X; Ma X
J Orthop Surg (Hong Kong); 2020; 28(3):2309499020966125. PubMed ID: 33155519
[TBL] [Abstract][Full Text] [Related]
12. Total ankle replacement design and positioning affect implant-bone micromotion and bone strains.
Sopher RS; Amis AA; Calder JD; Jeffers JRT
Med Eng Phys; 2017 Apr; 42():80-90. PubMed ID: 28233732
[TBL] [Abstract][Full Text] [Related]
13. Improve the performance of coated cemented hip stem through the advanced composite materials.
Hedia HS; Fouda N
Biomed Mater Eng; 2015; 25(3):313-26. PubMed ID: 26407117
[TBL] [Abstract][Full Text] [Related]
14. A comparative study of bone remodeling around hydroxyapatite-coated and novel radial functionally graded dental implants using finite element simulation.
Jafari B; Katoozian HR; Tahani M; Ashjaee N
Med Eng Phys; 2022 Apr; 102():103775. PubMed ID: 35346432
[TBL] [Abstract][Full Text] [Related]
15. Design and finite element analysis of femoral stem prosthesis using functional graded materials.
Ahirwar H; Sahu A; Gupta VK; Kumar P; Nanda HS
Comput Methods Biomech Biomed Engin; 2022 Aug; 25(11):1262-1275. PubMed ID: 34939875
[TBL] [Abstract][Full Text] [Related]
16. Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: A finite element analysis comparing titanium and PEEK.
Carpenter RD; Klosterhoff BS; Torstrick FB; Foley KT; Burkus JK; Lee CSD; Gall K; Guldberg RE; Safranski DL
J Mech Behav Biomed Mater; 2018 Apr; 80():68-76. PubMed ID: 29414477
[TBL] [Abstract][Full Text] [Related]
17. Influence of cancellous bone material and dead zone on stress-strain, bone stimulus and bone remodelling around the tibia for total ankle replacement.
Mondal S; Ghosh R
Proc Inst Mech Eng H; 2021 Feb; 235(2):185-196. PubMed ID: 33140692
[TBL] [Abstract][Full Text] [Related]
18. Thermal-mechanical study of functionally graded dental implants with the finite element method.
Wang F; Lee HP; Lu C
J Biomed Mater Res A; 2007 Jan; 80(1):146-58. PubMed ID: 17001649
[TBL] [Abstract][Full Text] [Related]
19. Bone remodelling around the tibia due to total ankle replacement: effects of implant material and implant-bone interfacial conditions.
Mondal S; Ghosh R
Comput Methods Biomech Biomed Engin; 2019 Dec; 22(16):1247-1257. PubMed ID: 31497997
[TBL] [Abstract][Full Text] [Related]
20. Comparison of various functionally graded femoral prostheses by finite element analysis.
Oshkour AA; Talebi H; Shirazi SF; Bayat M; Yau YH; Tarlochan F; Abu Osman NA
ScientificWorldJournal; 2014; 2014():807621. PubMed ID: 25302331
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]