113 related articles for article (PubMed ID: 38742487)
1. Electroacoustic evaluation of the bone conduction transducer B250 for vestibular and hearing diagnostics in comparison with Radioear B71 and B81.
Fredén Jansson KJ; Håkansson B; Persson AC; Verrecchia L; Reinfeldt S
Int J Audiol; 2024 May; ():1-7. PubMed ID: 38742487
[TBL] [Abstract][Full Text] [Related]
2. Electro-acoustic performance of the new bone vibrator Radioear B81: a comparison with the conventional Radioear B71.
Jansson KJ; Håkansson B; Johannsen L; Tengstrand T
Int J Audiol; 2015 May; 54(5):334-40. PubMed ID: 25519145
[TBL] [Abstract][Full Text] [Related]
3. Comparison of Bone-Conducted Cervical VEMPs Elicited by B71 and B81 Bone Vibrators.
Romero DJ; Piker EG; Thorne A; Clinard C
Ear Hear; 2021; 42(3):596-605. PubMed ID: 33577217
[TBL] [Abstract][Full Text] [Related]
4. Measurements of bone conduction auditory brainstem response with the new audiometric bone conduction transducer Radioear B81.
Keceli S; Stenfelt S
Int J Audiol; 2018 Aug; 57(8):577-583. PubMed ID: 29911916
[TBL] [Abstract][Full Text] [Related]
5. Influence of transducer types on bone conduction hearing thresholds.
Fröhlich L; Plontke SK; Rahne T
PLoS One; 2018; 13(4):e0195233. PubMed ID: 29641550
[TBL] [Abstract][Full Text] [Related]
6. Vibrotactile Thresholds on the Mastoid and Forehead Position of Deaf Patients Using Radioear B71 and B81.
Fredén Jansson KJ; Håkansson B; Reinfeldt S; Fröhlich L; Rahne T
Ear Hear; 2017; 38(6):714-723. PubMed ID: 28737551
[TBL] [Abstract][Full Text] [Related]
7. Effect of bone-conduction harmonic distortions on hearing thresholds.
Eichenauer A; Dillon H; Clinch B; Loi T
J Acoust Soc Am; 2014 Aug; 136(2):EL96-102. PubMed ID: 25096153
[TBL] [Abstract][Full Text] [Related]
8. Maximum Output and Low-Frequency Limitations of B71 and B81 Clinical Bone Vibrators: Implications for Vestibular Evoked Potentials.
Clinard CG; Piker EG; Thorne AP; Surface EN; Anderson AE; Beacham VA; Crouse MC; Whitney VH; Depaolis RA
Ear Hear; 2020; 41(4):847-854. PubMed ID: 31613822
[TBL] [Abstract][Full Text] [Related]
9. VEMP using a new low-frequency bone conduction transducer.
Håkansson B; Jansson KF; Tengstrand T; Johannsen L; Eeg-Olofsson M; Rigato C; Dahlström E; Reinfeldt S
Med Devices (Auckl); 2018; 11():301-312. PubMed ID: 30233258
[TBL] [Abstract][Full Text] [Related]
10. Characterization and Clinical Use of Bone Conduction Transducers at Extended High Frequencies.
Remenschneider AK; Cheng JT; Herrmann BS; Rosowski JJ
Hear Res; 2023 Mar; 429():108688. PubMed ID: 36628803
[TBL] [Abstract][Full Text] [Related]
11. Acoustic method for calibration of audiometric bone vibrators. II. Harmonic distortion.
Ginter SM; Margolis RH
J Acoust Soc Am; 2013 Jul; 134(1):EL33-7. PubMed ID: 23862903
[TBL] [Abstract][Full Text] [Related]
12. The balanced electromagnetic separation transducer a new bone conduction transducer.
Håkansson BE
J Acoust Soc Am; 2003 Feb; 113(2):818-25. PubMed ID: 12597176
[TBL] [Abstract][Full Text] [Related]
13. Bone Conduction Stimulated VEMP Using the B250 Transducer.
Fredén Jansson KJ; Håkansson B; Reinfeldt S; Persson AC; Eeg-Olofsson M
Med Devices (Auckl); 2021; 14():225-237. PubMed ID: 34267559
[TBL] [Abstract][Full Text] [Related]
14. Age Effects of Bone Conduction Vibration Vestibular-evoked Myogenic Potentials (VEMPs) Using B81 and Impulse Hammer Stimuli.
Patterson JN; Rodriguez AI; Gordon KR; Honaker JA; Janky KL
Ear Hear; 2021; 42(5):1328-1337. PubMed ID: 33735908
[TBL] [Abstract][Full Text] [Related]
15. Extended high-frequency bone conduction audiometry Calibration of bone conductor transducers in the conventional and extended high-frequency range.
Rhebergen KS
Int J Audiol; 2023 Feb; 62(2):182-191. PubMed ID: 35195500
[TBL] [Abstract][Full Text] [Related]
16. Ankle Audiometry: A Clinical Test for the Enhanced Hearing Sensitivity for Body Sounds in Superior Canal Dehiscence Syndrome.
Verrecchia L; Fredén Jansson KJ; Westin M; Velikoselskii A; Reinfeldt S; Håkansson B
Audiol Neurootol; 2023; 28(3):219-229. PubMed ID: 36634643
[TBL] [Abstract][Full Text] [Related]
17. Comparison of Thresholds Obtained With the Radioear B-71 and B-81 Bone-Conduction Transducers.
Rao A; Altus B; Schroeder R; Margolis RH
Ear Hear; 2020; 41(6):1775-1778. PubMed ID: 33136651
[TBL] [Abstract][Full Text] [Related]
18. Establishing transducers-dependent sensorineural acuity level normative data among young Malaysian adults.
Zakaria MN; Ensin EG; Awang MA; Salim R; Nik Othman NA; Rashid MFN
Med J Malaysia; 2023 Dec; 78(7):901-906. PubMed ID: 38159926
[TBL] [Abstract][Full Text] [Related]
19. Calibration force levels for bone conduction vibrators.
Billings BL; Winter M
J Speech Hear Res; 1977 Dec; 20(4):653-60. PubMed ID: 604679
[TBL] [Abstract][Full Text] [Related]
20. Influence of bone conduction transducer type and placement on ocular and cervical vestibular evoked myogenic potentials.
Fröhlich L; Wilke M; Plontke SK; Rahne T
Sci Rep; 2021 Apr; 11(1):8500. PubMed ID: 33875696
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]