These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 38742758)

  • 21. Impact of Circuit Size on Coagulation and Hemolysis Complications in Pediatric Extracorporeal Membrane Oxygenation.
    Maul TM; Aspenleiter M; Palmer D; Sharma MS; Viegas ML; Wearden PD
    ASAIO J; 2020; 66(9):1048-1053. PubMed ID: 31977350
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Surface-heparinized neonatal ECMO circuit--an experimental animal study.
    Frenckner B; Ehrén H; Palmér K; Gouda I; Larm O; Olsson P
    Perfusion; 1992 Jan; 7(1):47-51. PubMed ID: 10147699
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The impact of small movements with dual lumen cannulae during venovenous extracorporeal membrane oxygenation: A computational fluid dynamics analysis.
    Wong ZY; Azimi M; Khamooshi M; Wickramarachchi A; Burrell A; Gregory SD
    Comput Methods Programs Biomed; 2024 Jun; 250():108186. PubMed ID: 38692252
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Plasma-free hemoglobin levels in advanced vs. conventional infant and pediatric extracorporeal life support circuits.
    Cornelius AM; Riley JB; Schears GJ; Burkhart HM
    J Extra Corpor Technol; 2013 Mar; 45(1):21-5. PubMed ID: 23691780
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Mechanical component failures in 28,171 neonatal and pediatric extracorporeal membrane oxygenation courses from 1987 to 2006.
    Fleming GM; Gurney JG; Donohue JE; Remenapp RT; Annich GM
    Pediatr Crit Care Med; 2009 Jul; 10(4):439-44. PubMed ID: 19307816
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Extracorporeal Membrane Oxygenation (ECMO) for Refractory Cardiac Arrest.
    Hanneken K; Gaieski D; Vempati A; Hall R
    J Educ Teach Emerg Med; 2020 Oct; 5(4):S28-S58. PubMed ID: 37465336
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Preclinical biocompatibility study of ultra-compact durable ECMO system in chronic animal experiments for 2 weeks.
    Akiyama D; Katagiri N; Mizuno T; Tsukiya T; Takewa Y; Tatsumi E
    J Artif Organs; 2020 Dec; 23(4):335-341. PubMed ID: 32514701
    [TBL] [Abstract][Full Text] [Related]  

  • 28. In vitro effects of an extracorporeal membrane oxygenation circuit on the sequestration of ϵ-aminocaproic acid.
    Wagner D; Caraballo M; Waldvogel J; Peterson Y; Sun D
    Perfusion; 2017 Apr; 32(3):226-229. PubMed ID: 27815558
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Flow Monitoring of ECMO Circuit for Detecting Oxygenator Obstructions.
    Sarathy S; Turek JW; Chu J; Badheka A; Nino MA; Raghavan ML
    Ann Biomed Eng; 2021 Dec; 49(12):3636-3646. PubMed ID: 34705123
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A proposed objective scale for extracorporeal membrane oxygenation circuit thrombosis.
    Konsek H; Mealer C; Skidmore S; Collins M; Tchantchaleishvili V; Rajab TK
    Clin Transplant; 2023 Oct; 37(10):e15118. PubMed ID: 37658824
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Bacteria in Extracorporeal Membrane Oxygenation Circuit Clots of a Patient With Persistent Bacteremia: A Case Report.
    Drop JG; Verhage L; van Westreenen M; Wildschut ED; de Hoog M; van Beusekom H; van Ommen CH
    ASAIO J; 2023 Nov; 69(11):e463-e466. PubMed ID: 37200474
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The History of Extracorporeal Membrane Oxygenation and the Development of Extracorporeal Membrane Oxygenation Anticoagulation.
    Bartlett R; Arachichilage DJ; Chitlur M; Hui SR; Neunert C; Doyle A; Retter A; Hunt BJ; Lim HS; Saini A; Renné T; Kostousov V; Teruya J
    Semin Thromb Hemost; 2024 Feb; 50(1):81-90. PubMed ID: 36750217
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Extracorporeal membrane oxygenation circuitry.
    Lequier L; Horton SB; McMullan DM; Bartlett RH
    Pediatr Crit Care Med; 2013 Jun; 14(5 Suppl 1):S7-12. PubMed ID: 23735989
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Novel use of the AngioVac® system to remove thrombus during simultaneous extracorporeal membrane oxygenation life support.
    Griffith KE; Jenkins E; Copenhaver W; Williams DM
    Perfusion; 2016 Mar; 31(2):164-8. PubMed ID: 26034197
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Unfractionated heparin activity measured by anti-factor Xa levels is associated with the need for extracorporeal membrane oxygenation circuit/membrane oxygenator change: a retrospective pediatric study.
    Irby K; Swearingen C; Byrnes J; Bryant J; Prodhan P; Fiser R
    Pediatr Crit Care Med; 2014 May; 15(4):e175-82. PubMed ID: 24622165
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Neutrophil extracellular traps are increased after extracorporeal membrane oxygenation support initiation and present in thrombus: A preclinical study using sheep as an animal model.
    Zhang Y; Peng R; Pei S; Gao S; Sun Y; Cheng G; Yu D; Wang X; Gao Z; Ji B; Zhou Z
    Thromb Res; 2023 Jan; 221():173-182. PubMed ID: 36402603
    [TBL] [Abstract][Full Text] [Related]  

  • 37. D-dimers Are a Predictor of Clot Volume Inside Membrane Oxygenators During Extracorporeal Membrane Oxygenation.
    Dornia C; Philipp A; Bauer S; Stroszczynski C; Schreyer AG; Müller T; Koehl GE; Lehle K
    Artif Organs; 2015 Sep; 39(9):782-7. PubMed ID: 25845704
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Technical Indicators to Evaluate the Degree of Large Clot Formation Inside the Membrane Fiber Bundle of an Oxygenator in an In Vitro Setup.
    Kaesler A; Hesselmann F; Zander MO; Schlanstein PC; Wagner G; Bruners P; Schmitz-Rode T; Steinseifer U; Arens J
    Artif Organs; 2019 Feb; 43(2):159-166. PubMed ID: 30084492
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Circuit change during extracorporeal membrane oxygenation: single-center retrospective study of 48 changes.
    Genty T; Burguburu S; Imbert A; Roman C; Camille W; Thès J; Stéphan F
    Crit Care; 2023 Jun; 27(1):219. PubMed ID: 37269022
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Establishment and evaluation of a rat model of extracorporeal membrane oxygenation (ECMO) thrombosis using a 3D-printed mock-oxygenator.
    Umei N; Lai A; Miller J; Shin S; Roberts K; Ai Qatarneh S; Ichiba S; Sakamoto A; Cook KE
    J Transl Med; 2021 Apr; 19(1):179. PubMed ID: 33910585
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.