148 related articles for article (PubMed ID: 38752245)
1. [Effectiveness of Kirschner wire fixation for proximal phalangeal bone avulsion fracture caused by A2 circular trochlea injury of flexor digitorum tendon].
Yang H; Wang B; Guo L; Liu Z; Li Q
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2024 May; 38(5):583-587. PubMed ID: 38752245
[TBL] [Abstract][Full Text] [Related]
2. [MODIFIED INTRAMEDULLARY FIXATION WITH TWO Kirschner WIRES FOR EXTRA-ARTICULAR FRACTURE OF PROXIMAL PHALANGEAL BASE].
Li S; Wu K; Xie L; Chen L
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Aug; 30(8):935-938. PubMed ID: 29786219
[TBL] [Abstract][Full Text] [Related]
3. [Effectiveness on treatment of metacarpal avulsion fracture with Kirschner wire buckling combined with bone fixation].
Yang H; Wang B; Huang L; Guo L; Liu Z; Li H; Miao J
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Nov; 37(11):1390-1393. PubMed ID: 37987050
[TBL] [Abstract][Full Text] [Related]
4. [Treatment of Wehbe-Schneider types
Li W; Zhang J; An Q; Zheng Z; Guan J
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Apr; 36(4):400-404. PubMed ID: 35426276
[TBL] [Abstract][Full Text] [Related]
5. Kirschner Wires Versus Titanium Plates and Screws in Management of Unstable Phalangeal Fractures: A Randomized, Controlled Clinical Trial.
El-Saeed M; Sallam A; Radwan M; Metwally A
J Hand Surg Am; 2019 Dec; 44(12):1091.e1-1091.e9. PubMed ID: 30803743
[TBL] [Abstract][Full Text] [Related]
6. Simultaneous juxta-epiphyseal proximal phalanx fracture with flexor tendon entrapment in a child: a case report and review of literature.
Rodríguez-Vega V; Pretell-Mazzini J; Marti-Ciruelos R; Jorge-Mora A; de la Mano AC
J Pediatr Orthop B; 2013 Mar; 22(2):148-52. PubMed ID: 22561910
[TBL] [Abstract][Full Text] [Related]
7. Comparison of low-profile plate-screw and Kirschner-wire osteosynthesis outcomes in extra-articular unstable proximal phalangeal fractures.
Köse A; Topal M; Engin MÇ; Şencan A; Dinçer R; Baran T
Eur J Orthop Surg Traumatol; 2019 Apr; 29(3):597-604. PubMed ID: 30426217
[TBL] [Abstract][Full Text] [Related]
8. [Short-term effectiveness of Kirschner wire elastic fixation in treatment of Doyle type
Yan H; Tan Q; Zhou S; Yang J; Li L; Wang J; Shi X; Xia C; Li Y
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2017 Nov; 31(11):1287-1290. PubMed ID: 29798578
[TBL] [Abstract][Full Text] [Related]
9. The hook plate technique for fixation of phalangeal avulsion fractures.
Kang GC; Yam A; Phoon ES; Lee JY; Teoh LC
J Bone Joint Surg Am; 2012 Jun; 94(11):e72. PubMed ID: 22637212
[TBL] [Abstract][Full Text] [Related]
10. Flexor Tendon Entrapment at the Malunited Base Fracture of the Proximal Phalanx of the Finger in Child: A Case Report.
Lee YK; Park S; Lee M
Medicine (Baltimore); 2015 Sep; 94(35):e1408. PubMed ID: 26334897
[TBL] [Abstract][Full Text] [Related]
11. [Application of absorbable anchor combined with Kirschner wire in reconstruction of extension function of old mallet finger].
Cheng D; Zhou Z; Lin Z; Liu H; Yang F; Wang J; Guo S
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Apr; 37(4):443-446. PubMed ID: 37070311
[TBL] [Abstract][Full Text] [Related]
12. Fixation of a Type 3 Flexor Digitorum Avulsion Injury.
Weber MB; Chepla KJ; Bafus BT
Tech Hand Up Extrem Surg; 2019 Dec; 23(4):160-164. PubMed ID: 31157734
[TBL] [Abstract][Full Text] [Related]
13. Long-term objective results of proximal phalanx fracture treatment.
Ozçelik D; Toplu G; Unveren T; Kaçağan F; Senyuva CG
Ulus Travma Acil Cerrahi Derg; 2011 May; 17(3):253-60. PubMed ID: 21935805
[TBL] [Abstract][Full Text] [Related]
14. Correlation between extension-block K-wire insertion angle and postoperative extension loss in mallet finger fracture.
Lee SK; Kim YH; Moon KH; Choy WS
Orthop Traumatol Surg Res; 2018 Feb; 104(1):127-132. PubMed ID: 29024745
[TBL] [Abstract][Full Text] [Related]
15. Open reduction and compression with double Kirschner wires for the treatment of old bony mallet finger.
Tang J; Wu K; Wang J; Zhang J
J Orthop Surg Res; 2019 Dec; 14(1):459. PubMed ID: 31864378
[TBL] [Abstract][Full Text] [Related]
16. [Results after osteosynthesis of extraarticular proximal phalangeal fractures].
Egloff C; Sproedt J; Jandali AR
Handchir Mikrochir Plast Chir; 2012 Jan; 44(1):5-10. PubMed ID: 22382904
[TBL] [Abstract][Full Text] [Related]
17. [Effectiveness of multidirectionally three-dimensional steel wire ring sleeve fixation in treatment of inferior patellar pole avulsion fractures].
Xie M; Liao D; Gong K; Huang C; Chen S; Ren Y; Zheng W
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2021 Feb; 35(2):183-187. PubMed ID: 33624471
[TBL] [Abstract][Full Text] [Related]
18. Cemented K-wire fixation for the treatment of shaft fractures of middle phalanges.
Zhang X; Shao X; Zhang Z; Zhang G; Yu Y; Wang L; Lyu L
Injury; 2018 Feb; 49(2):351-358. PubMed ID: 29055495
[TBL] [Abstract][Full Text] [Related]
19. Dorsal versus lateral plate fixation of finger proximal phalangeal fractures: a retrospective study.
Robinson LP; Gaspar MP; Strohl AB; Teplitsky SL; Gandhi SD; Kane PM; Osterman AL
Arch Orthop Trauma Surg; 2017 Apr; 137(4):567-572. PubMed ID: 28236187
[TBL] [Abstract][Full Text] [Related]
20. [Treatment of ulnar collateral ligament avulsion fracture of thumb metacarpophalangeal joint using a combination of Kirschner wire and silk tension band].
Gao S; Feng S; Jiao C
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2012 Dec; 26(12):1466-8. PubMed ID: 23316637
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]