128 related articles for article (PubMed ID: 38754878)
21. High-flow nasal oxygenation versus face mask oxygenation for preoxygenation in patients undergoing double-lumen endobronchial intubation: protocol of a randomised controlled trial.
He R; Fang Y; Jiang Y; Yao D; Li Z; Zheng W; Liu Z; Luo N
BMJ Open; 2024 Mar; 14(3):e080422. PubMed ID: 38485472
[TBL] [Abstract][Full Text] [Related]
22. Randomized clinical trial comparing double-lumen tube and EZ-Blocker for single-lung ventilation.
Ruetzler K; Grubhofer G; Schmid W; Papp D; Nabecker S; Hutschala D; Lang G; Hager H
Br J Anaesth; 2011 Jun; 106(6):896-902. PubMed ID: 21493621
[TBL] [Abstract][Full Text] [Related]
23. Characteristics of Double-Lumen Tubes Determine Bronchial Airway Pressure.
Spaeth J; Hojnik A; Ott M; Wirth S; Schneider M; Loop T; Schumann S
J Cardiothorac Vasc Anesth; 2016 Aug; 30(4):954-60. PubMed ID: 27521966
[TBL] [Abstract][Full Text] [Related]
24. Right displacement of trachea to reduce right bronchial misplacement of left double lumen tube: a prospective, double-blind, randomized study.
Guan J; Zhu W; Xiao X; Huang Z; Xing J; Hei Z; Zhang Y; Yao W
BMC Anesthesiol; 2022 Oct; 22(1):312. PubMed ID: 36203158
[TBL] [Abstract][Full Text] [Related]
25. Bronchial blocker versus double-lumen endobronchial tube in minimally invasive cardiac surgery.
Zhang C; Yue J; Li M; Jiang W; Pan Y; Song Z; Shi C; Fan W; Pan Z
BMC Pulm Med; 2019 Nov; 19(1):207. PubMed ID: 31706317
[TBL] [Abstract][Full Text] [Related]
26. Placement of left double-lumen endobronchial tubes with or without a stylet.
Lieberman D; Littleford J; Horan T; Unruh H
Can J Anaesth; 1996 Mar; 43(3):238-42. PubMed ID: 8829862
[TBL] [Abstract][Full Text] [Related]
27. Chest Computed Tomography Image for Accurately Predicting the Optimal Insertion Depth of Left-Sided Double-Lumen Tube.
Liu Z; Zhao L; Jia Q; Yang X; Liang SJ; He W
J Cardiothorac Vasc Anesth; 2018 Apr; 32(2):855-859. PubMed ID: 29221981
[TBL] [Abstract][Full Text] [Related]
28. A Randomized Comparison of Positional Stability: The EZ-Blocker Versus Left-Sided Double-Lumen Endobronchial Tubes in Adult Patients Undergoing Thoracic Surgery.
Morris BN; Fernando RJ; Garner CR; Johnson SD; Gardner JC; Marchant BE; Johnson KN; Harris HM; Russell GB; Wudel LJ; Templeton TW
J Cardiothorac Vasc Anesth; 2021 Aug; 35(8):2319-2325. PubMed ID: 33419686
[TBL] [Abstract][Full Text] [Related]
29. Combined use of the ProSeal laryngeal mask airway and a bronchial blocker vs. a double-lumen endobronchial tube in thoracoscopic surgery: A randomized controlled trial.
Nakanishi T; Sento Y; Kamimura Y; Nakamura R; Hashimoto H; Okuda K; Nakanishi R; Sobue K
J Clin Anesth; 2023 Sep; 88():111136. PubMed ID: 37137259
[TBL] [Abstract][Full Text] [Related]
30. Disconnection technique with a bronchial blocker for improving lung deflation: a comparison with a double-lumen tube and bronchial blocker without disconnection.
Yoo JY; Kim DH; Choi H; Kim K; Chae YJ; Park SY
J Cardiothorac Vasc Anesth; 2014 Aug; 28(4):904-7. PubMed ID: 24231197
[TBL] [Abstract][Full Text] [Related]
31. Combination of computed tomography measurements and flexible video bronchoscope guidance for accurate placement of the right-sided double-lumen tube: a randomised controlled trial.
Li J; Qian Y; Lei Y; Huo W; Xu M; Zhang Y; Ji Q; Yang J; Liu H; Hou Y
BMJ Open; 2023 Nov; 13(11):e066541. PubMed ID: 38011975
[TBL] [Abstract][Full Text] [Related]
32. Time to tracheal intubation over a fibreoptic bronchoscope using a silicone left double-lumen endobronchial tube versus polyvinyl chloride single-lumen tube with bronchial blocker: a randomized controlled non-inferiority trial.
Yoo JY; Chae YJ; Park SY; Haam S; Kim M; Kim DH
J Thorac Dis; 2019 Mar; 11(3):901-908. PubMed ID: 31019779
[TBL] [Abstract][Full Text] [Related]
33. A randomized trial to assess the effect of cricoid displacing maneuver on the success rate of blind placement of double-lumen tube and Univent bronchial blocker.
Xu Z; Yu H; Luo Y; Ye Y; Zhou C; Liang P
Ann Palliat Med; 2021 Feb; 10(2):1976-1984. PubMed ID: 33440969
[TBL] [Abstract][Full Text] [Related]
34. Glidescope versus Airtraq DL for double-lumen tracheal tube insertion in patients with a predicted or known difficult airway: A randomised study.
Belze O; Lepage E; Bazin Y; Kerourin P; Fusciardi J; Remérand F; Espitalier F
Eur J Anaesthesiol; 2017 Jul; 34(7):456-463. PubMed ID: 28525401
[TBL] [Abstract][Full Text] [Related]
35. A modified technique to improve the outcome of intubation with a left-sided double-lumen endobronchial tube.
Hsu HT; Chou SH; Chou CY; Tseng KY; Kuo YW; Chen MC; Cheng KI
BMC Anesthesiol; 2014; 14():72. PubMed ID: 25206313
[TBL] [Abstract][Full Text] [Related]
36. Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size.
Eberle B; Weiler N; Vogel N; Kauczor HU; Heinrichs W
J Cardiothorac Vasc Anesth; 1999 Oct; 13(5):532-7. PubMed ID: 10527220
[TBL] [Abstract][Full Text] [Related]
37. GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: a randomized, controlled, prospective trial.
Huang P; Zhou R; Lu Z; Hang Y; Wang S; Huang Z
BMC Anesthesiol; 2020 May; 20(1):119. PubMed ID: 32434470
[TBL] [Abstract][Full Text] [Related]
38. The effects of thermal softening of double-lumen endobronchial tubes on postoperative sore throat, hoarseness and vocal cord injuries: a prospective double-blind randomized trial.
Seo JH; Cho CW; Hong DM; Jeon Y; Bahk JH
Br J Anaesth; 2016 Feb; 116(2):282-8. PubMed ID: 26787799
[TBL] [Abstract][Full Text] [Related]
39. Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial.
Seo JH; Yoon S; Min SH; Row HS; Bahk JH
PLoS One; 2019; 14(1):e0210711. PubMed ID: 30645611
[TBL] [Abstract][Full Text] [Related]
40. [A comparison of double-lumen endotracheal tube with univent blocker and bronchial blocker during thoracic surgical anesthesia].
Zheng H; Duan Y; Geng WM; Liu W; Gao GK; Wang C
Zhonghua Yi Xue Za Zhi; 2012 Sep; 92(35):2481-4. PubMed ID: 23158714
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]