These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 38762819)

  • 1. Transvenous extraction of conduction system pacing leads: An international multicenter (TECSPAM) study.
    Vijayaraman P; Trivedi RS; Koneru JN; Sharma PS; De Pooter J; Schaller RD; Cano Ó; Whinnett ZI; Migliore F; Ponnusamy SS; Skeete JR; Zanon F; Heuverswyn FV; Kolominsky J; Pittorru R; Mumtaz M; Ellenbogen KA; Herweg B
    Heart Rhythm; 2024 May; ():. PubMed ID: 38762819
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Extraction of the permanent His bundle pacing lead: Safety outcomes and feasibility of reimplantation.
    Vijayaraman P; Subzposh FA; Naperkowski A
    Heart Rhythm; 2019 Aug; 16(8):1196-1203. PubMed ID: 31200093
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience.
    Migliore F; Pittorru R; De Lazzari M; Tarzia V; Pastore G; Marcantoni L; Catanzariti D; Gerosa G; Zanon F
    J Interv Card Electrophysiol; 2024 Jan; 67(1):175-182. PubMed ID: 37365481
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Result of the Physiologic Pacing Registry, an international multicenter prospective observational study of conduction system pacing.
    Vazquez PM; Mohamed U; Zanon F; Lustgarten DL; Atwater B; Whinnett ZI; Curila K; Dinerman J; Molina-Lerma M; Wiley J; Grammatico A; Lee K; Vijayaraman P
    Heart Rhythm; 2023 Dec; 20(12):1617-1625. PubMed ID: 37348800
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads.
    Perino AC; Wang PJ; Lloyd M; Zanon F; Fujiu K; Osman F; Briongos-Figuero S; Sato T; Aksu T; Jastrzebski M; Sideris S; Rao P; Boczar K; Yuan-Ning X; Wu M; Namboodiri N; Garcia R; Kataria V; De Pooter J; Przibille O; Gehi AK; Cano O; Katsouras G; Cai B; Astheimer K; Tanawuttiwat T; Datino T; Rizkallah J; Alasti M; Feld G; Barrio-Lopez MT; Gilmore M; Conti S; Yanagisawa S; Indik JH; Zou J; Saha SA; Rodriguez-Munoz D; Chang KC; Lebedev DS; Leal MA; Haeberlin A; Forno ARJD; Orlov M; Frutos M; Cabanas-Grandio P; Lyne J; Leyva F; Tolosana JM; Ollitrault P; Vergara P; Balla C; Devabhaktuni SR; Forleo G; Letsas KP; Verma A; Moak JP; Shelke AB; Curila K; Cronin EM; Futyma P; Wan EY; Lazzerini PE; Bisbal F; Casella M; Turitto G; Rosenthal L; Bunch TJ; Baszko A; Clementy N; Cha YM; Chen HC; Galand V; Schaller R; Jarman JWE; Harada M; Wei Y; Kusano K; Schmidt C; Hurtado MAA; Naksuk N; Hoshiyama T; Kancharla K; Iida Y; Mizobuchi M; Morin DP; Cay S; Paglino G; Dahme T; Agarwal S; Vijayaraman P; Sharma PS
    J Interv Card Electrophysiol; 2023 Oct; 66(7):1589-1600. PubMed ID: 36607529
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Left bundle branch area pacing using stylet-driven pacing leads with a new delivery sheath: A comparison with lumen-less leads.
    De Pooter J; Calle S; Timmermans F; Van Heuverswyn F
    J Cardiovasc Electrophysiol; 2021 Feb; 32(2):439-448. PubMed ID: 33355969
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Initial experience with stylet-driven versus lumenless lead delivery systems for left bundle branch area pacing.
    Braunstein ED; Kagan RD; Olshan DS; Gabriels JK; Thomas G; Ip JE; Markowitz SM; Lerman BB; Liu CF; Cheung JW
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):710-717. PubMed ID: 36571159
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Atrioventricular junction ablation in patients with conduction system pacing leads: A comparison of His-bundle vs left bundle branch area pacing leads.
    Pillai A; Kolominsky J; Koneru JN; Kron J; Shepard RK; Kalahasty G; Huang W; Verma A; Ellenbogen KA
    Heart Rhythm; 2022 Jul; 19(7):1116-1123. PubMed ID: 35351624
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Result of the left bundle branch area pacing data collection registry, an international multicenter study of conduction system pacing with a Tendril STS 2088 stylet-driven lead.
    Vijayaraman P; Foo D; Lim TSE; Diamantakos E; Verma S; Hourdain J; Pandurangi U; Bhargava K; Zanon F; Stone J; Lee K; Nair D
    J Cardiovasc Electrophysiol; 2024 Jul; 35(7):1452-1460. PubMed ID: 38757909
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Initial experience of left bundle branch area pacing using stylet-driven pacing leads: A multicenter study.
    De Pooter J; Ozpak E; Calle S; Peytchev P; Heggermont W; Marchandise S; Provenier F; Francois B; Anné W; Pollet P; Barbraud C; Gillis K; Timmermans F; Van Heuverswyn F; Tung R; Wauters A; le Polain de Waroux JB
    J Cardiovasc Electrophysiol; 2022 Jul; 33(7):1540-1549. PubMed ID: 35598298
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Left bundle branch area pacing in patients with atrioventricular conduction disease: A prospective multicenter study.
    Raymond-Paquin A; Verma A; Kolominsky J; Sanchez-Somonte P; Gul EE; Pillai A; Kron J; Shepard R; Kalahasty G; Tsang B; Khaykin Y; Pantano A; Koneru JN; Ellenbogen KA
    Heart Rhythm; 2022 Sep; 19(9):1484-1490. PubMed ID: 35562056
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Utility of a guiding catheter for conduction system pacing: An early multicenter experience.
    De Pooter J; Bulava A; Gras D; Timmer S; Chin-Pang Chan G; Clementy N; Pathak RK; Healy S; Lüsebrink U; Zanon F
    Heart Rhythm O2; 2024 Jan; 5(1):8-16. PubMed ID: 38312208
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Caveats related to conduction system pacing utilizing a proprietary deflectable mapping catheter with a stylet-driven lead.
    Ghosh A; Ka MA; Sriram CS; Pandurangi UM
    J Interv Card Electrophysiol; 2024 Jun; 67(4):759-771. PubMed ID: 37840120
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Success and complication rates of conduction system pacing: a meta-analytical observational comparison of left bundle branch area pacing and His bundle pacing.
    Parlavecchio A; Vetta G; Coluccia G; Pistelli L; Caminiti R; Crea P; Ajello M; Magnocavallo M; Dattilo G; Foti R; Carerj S; Chierchia GB; de Asmundis C; Della Rocca DG; Palmisano P
    J Interv Card Electrophysiol; 2024 Jun; 67(4):719-729. PubMed ID: 37642801
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Acute performance of stylet driven leads for left bundle branch area pacing: A comparison with lumenless leads.
    Cano Ó; Navarrete-Navarro J; Zalavadia D; Jover P; Osca J; Bahadur R; Izquierdo M; Navarro J; Subzposh FA; Ayala HD; Martínez-Dolz L; Vijayaraman P; Batul SA
    Heart Rhythm O2; 2023 Dec; 4(12):765-776. PubMed ID: 38204462
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial Experience, Safety, and Feasibility of Left Bundle Branch Area Pacing: A Multicenter Prospective Study.
    Padala SK; Master VM; Terricabras M; Chiocchini A; Garg A; Kron J; Shepard R; Kalahasty G; Azizi Z; Tsang B; Khaykin Y; Pantano A; Koneru JN; Ellenbogen KA; Verma A
    JACC Clin Electrophysiol; 2020 Dec; 6(14):1773-1782. PubMed ID: 33357573
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing.
    Vijayaraman P; Subzposh FA; Naperkowski A; Panikkath R; John K; Mascarenhas V; Bauch TD; Huang W
    Heart Rhythm; 2019 Dec; 16(12):1774-1782. PubMed ID: 31136869
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Left bundle branch area pacing using a stylet-driven, retractable-helix lead: Short-term results from a prospective multicenter IDE trial (the BIO-CONDUCT study).
    Liu CF; Prasad KV; Moretta A; Vijayaraman P; Zanon F; Gleva M; De Pooter J; Chinitz LA;
    Heart Rhythm; 2024 May; ():. PubMed ID: 38772432
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Predictors of implantation failure in left bundle branch area pacing using a lumenless lead in patients with bradycardia.
    Kato H; Sato T; Shimeno K; Mito S; Nishida T; Soejima K
    J Arrhythm; 2023 Oct; 39(5):766-775. PubMed ID: 37799795
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preliminary experience of permanent left bundle branch area pacing using stylet-directed pacing lead without delivery sheath.
    Sun Y; Yao X; Zhou X; Jiang C; Zhang J; Sheng X; Wang M; Yang Y; Pan Y; Su L; Chen X; Fu G
    Pacing Clin Electrophysiol; 2022 Aug; 45(8):993-1003. PubMed ID: 35437783
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.