BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

45 related articles for article (PubMed ID: 38763962)

  • 21. Motion correction and its impact on quantification in dynamic total-body 18F-fluorodeoxyglucose PET.
    Sun T; Wu Y; Wei W; Fu F; Meng N; Chen H; Li X; Bai Y; Wang Z; Ding J; Hu D; Chen C; Hu Z; Liang D; Liu X; Zheng H; Yang Y; Zhou Y; Wang M
    EJNMMI Phys; 2022 Sep; 9(1):62. PubMed ID: 36104468
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Total-body parametric imaging using the Patlak model: Feasibility of reduced scan time.
    Wu Y; Feng T; Shen Y; Fu F; Meng N; Li X; Xu T; Sun T; Gu F; Wu Q; Zhou Y; Han H; Bai Y; Wang M
    Med Phys; 2022 Jul; 49(7):4529-4539. PubMed ID: 35394071
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical feasibility and impact of data-driven respiratory motion compensation studied in 200 whole-body
    Dias AH; Schleyer P; Vendelbo MH; Hjorthaug K; Gormsen LC; Munk OL
    EJNMMI Res; 2022 Mar; 12(1):16. PubMed ID: 35347465
    [TBL] [Abstract][Full Text] [Related]  

  • 24. First results on kinetic modelling and parametric imaging of dynamic
    Sari H; Mingels C; Alberts I; Hu J; Buesser D; Shah V; Schepers R; Caluori P; Panin V; Conti M; Afshar-Oromieh A; Shi K; Eriksson L; Rominger A; Cumming P
    Eur J Nucl Med Mol Imaging; 2022 May; 49(6):1997-2009. PubMed ID: 34981164
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Whole-Body Parametric Imaging of
    Wu Y; Feng T; Zhao Y; Xu T; Fu F; Huang Z; Meng N; Li H; Shao F; Wang M
    J Nucl Med; 2022 Apr; 63(4):622-628. PubMed ID: 34385335
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Performance Characteristics of the Biograph Vision Quadra PET/CT System with a Long Axial Field of View Using the NEMA NU 2-2018 Standard.
    Prenosil GA; Sari H; Fürstner M; Afshar-Oromieh A; Shi K; Rominger A; Hentschel M
    J Nucl Med; 2022 Mar; 63(3):476-484. PubMed ID: 34301780
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Dynamic
    Wang J; Shao Y; Liu B; Wang X; Geist BK; Li X; Li F; Zhao H; Hacker M; Ding H; Zhang H; Huo L
    BMC Med Imaging; 2021 May; 21(1):90. PubMed ID: 34034664
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Quantitative PET in the 2020s: a roadmap.
    Meikle SR; Sossi V; Roncali E; Cherry SR; Banati R; Mankoff D; Jones T; James M; Sutcliffe J; Ouyang J; Petibon Y; Ma C; El Fakhri G; Surti S; Karp JS; Badawi RD; Yamaya T; Akamatsu G; Schramm G; Rezaei A; Nuyts J; Fulton R; Kyme A; Lois C; Sari H; Price J; Boellaard R; Jeraj R; Bailey DL; Eslick E; Willowson KP; Dutta J
    Phys Med Biol; 2021 Mar; 66(6):06RM01. PubMed ID: 33339012
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Assessment of population-based input functions for Patlak imaging of whole body dynamic
    Naganawa M; Gallezot JD; Shah V; Mulnix T; Young C; Dias M; Chen MK; Smith AM; Carson RE
    EJNMMI Phys; 2020 Nov; 7(1):67. PubMed ID: 33226522
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Total Body PET: Why, How, What for?
    Surti S; Pantel AR; Karp JS
    IEEE Trans Radiat Plasma Med Sci; 2020 May; 4(3):283-292. PubMed ID: 33134653
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Performance Evaluation of the uEXPLORER Total-Body PET/CT Scanner Based on NEMA NU 2-2018 with Additional Tests to Characterize PET Scanners with a Long Axial Field of View.
    Spencer BA; Berg E; Schmall JP; Omidvari N; Leung EK; Abdelhafez YG; Tang S; Deng Z; Dong Y; Lv Y; Bao J; Liu W; Li H; Jones T; Badawi RD; Cherry SR
    J Nucl Med; 2021 Jun; 62(6):861-870. PubMed ID: 33008932
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical feasibility and impact of fully automated multiparametric PET imaging using direct Patlak reconstruction: evaluation of 103 dynamic whole-body
    Dias AH; Pedersen MF; Danielsen H; Munk OL; Gormsen LC
    Eur J Nucl Med Mol Imaging; 2021 Mar; 48(3):837-850. PubMed ID: 32894338
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Kinetic modeling and parametric imaging with dynamic PET for oncological applications: general considerations, current clinical applications, and future perspectives.
    Dimitrakopoulou-Strauss A; Pan L; Sachpekidis C
    Eur J Nucl Med Mol Imaging; 2021 Jan; 48(1):21-39. PubMed ID: 32430580
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Total-Body Dynamic Reconstruction and Parametric Imaging on the uEXPLORER.
    Zhang X; Xie Z; Berg E; Judenhofer MS; Liu W; Xu T; Ding Y; Lv Y; Dong Y; Deng Z; Tang S; Shi H; Hu P; Chen S; Bao J; Li H; Zhou J; Wang G; Cherry SR; Badawi RD; Qi J
    J Nucl Med; 2020 Feb; 61(2):285-291. PubMed ID: 31302637
    [TBL] [Abstract][Full Text] [Related]  

  • 35. PennPET Explorer: Design and Preliminary Performance of a Whole-Body Imager.
    Karp JS; Viswanath V; Geagan MJ; Muehllehner G; Pantel AR; Parma MJ; Perkins AE; Schmall JP; Werner ME; Daube-Witherspoon ME
    J Nucl Med; 2020 Jan; 61(1):136-143. PubMed ID: 31227573
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dynamic PET of human liver inflammation: impact of kinetic modeling with optimization-derived dual-blood input function.
    Wang G; Corwin MT; Olson KA; Badawi RD; Sarkar S
    Phys Med Biol; 2018 Jul; 63(15):155004. PubMed ID: 29847315
    [TBL] [Abstract][Full Text] [Related]  

  • 37. 18F-FDG kinetics parameters depend on the mechanism of injury in early experimental acute respiratory distress syndrome.
    de Prost N; Feng Y; Wellman T; Tucci MR; Costa EL; Musch G; Winkler T; Harris RS; Venegas JG; Chao W; Vidal Melo MF
    J Nucl Med; 2014 Nov; 55(11):1871-7. PubMed ID: 25286924
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Direct estimation of kinetic parametric images for dynamic PET.
    Wang G; Qi J
    Theranostics; 2013 Nov; 3(10):802-15. PubMed ID: 24396500
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Image-derived input function for brain PET studies: many challenges and few opportunities.
    Zanotti-Fregonara P; Chen K; Liow JS; Fujita M; Innis RB
    J Cereb Blood Flow Metab; 2011 Oct; 31(10):1986-98. PubMed ID: 21811289
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Robust learning-based parsing and annotation of medical radiographs.
    Tao Y; Peng Z; Krishnan A; Zhou XS
    IEEE Trans Med Imaging; 2011 Feb; 30(2):338-50. PubMed ID: 20876012
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 3.