These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 38770050)

  • 1. Complications of XEN gel stent implantation for the treatment of glaucoma: a systematic review.
    Gan L; Wang L; Chen J; Tang L
    Front Med (Lausanne); 2024; 11():1360051. PubMed ID: 38770050
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [XEN
    Buffault J; Baudouin C; Labbé A
    J Fr Ophtalmol; 2019 Apr; 42(4):391-403. PubMed ID: 30879831
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Management of XEN Gel Stent Exposure with Conjunctival Erosion via Rotational Conjunctival Flap and Amniotic Membrane Transplantation-A Case Report.
    Lee CK; Seo JH; Lim SH
    Medicina (Kaunas); 2022 Nov; 58(11):. PubMed ID: 36363538
    [No Abstract]   [Full Text] [Related]  

  • 4. XEN
    Buffault J; Baudouin C; Labbé A
    J Fr Ophtalmol; 2019 Feb; 42(2):e37-e46. PubMed ID: 30683533
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Suprachoroidal Hemorrhage after XEN Gel Implant Requiring Surgical Drainage.
    Wang K; Wang JC; Sarrafpour S
    J Curr Glaucoma Pract; 2022; 16(2):132-135. PubMed ID: 36128082
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Recurrent Exposure of XEN Gel Stent Implant and Conjunctival Erosion.
    Arnould L; Theillac V; Moran S; Gatinel D; Grise-Dulac A
    J Glaucoma; 2019 Mar; 28(3):e37-e40. PubMed ID: 30676470
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of Needling Revision After XEN Gel Stent Implantation: A Prospective Study.
    Midha N; Gillmann K; Chaudhary A; Mermoud A; Mansouri K
    J Glaucoma; 2020 Jan; 29(1):11-14. PubMed ID: 31702711
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Conjunctival bleb tearing by XEN gel stent after conjunctival compression sutures.
    Montolío-Marzo S; Lanzagorta-Aresti A; Piá-Ludeña JV; Davó-Cabrera JM
    Eur J Ophthalmol; 2022 Jan; 32(1):NP76-NP78. PubMed ID: 33176452
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ab-Externo Implantation of XEN Gel Stent for Refractory Steroid-Induced Glaucoma After Lamellar Keratoplasty.
    Tan SY; Md Din N; Mohd Khialdin S; Wan Abdul Halim WH; Tang SF
    Cureus; 2021 Feb; 13(2):e13320. PubMed ID: 33738163
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoperative suprachoroidal hemorrhage during Xen gel stent implantation.
    Liu JC; Green W; Sheybani A; Lind JT
    Am J Ophthalmol Case Rep; 2020 Mar; 17():100600. PubMed ID: 32025590
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis.
    Yang X; Zhao Y; Zhong Y; Duan X
    BMC Ophthalmol; 2022 Jul; 22(1):305. PubMed ID: 35836197
    [TBL] [Abstract][Full Text] [Related]  

  • 12. SUBCONJUNCTIVAL FRAGMENTATION OF A PREVIOUSLY EFFICIENT XEN GEL STENT IMPLANTATION AND SUCCESSFUL BLEB FORMATION: A CASE REPORT.
    Novak-Lauš K; Knežević L; Marić G; Zorić Geber M; Vatavuk Z
    Acta Clin Croat; 2019 Dec; 58(4):767-770. PubMed ID: 32595262
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MIGS: therapeutic success of combined Xen Gel Stent implantation with cataract surgery.
    Hohberger B; Welge-Lüßen UC; Lämmer R
    Graefes Arch Clin Exp Ophthalmol; 2018 Mar; 256(3):621-625. PubMed ID: 29335776
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Outcomes of Deep Sclerectomy following Failed XEN Gel Stent Implantation in Open-Angle Glaucoma: A Prospective Study.
    Bravetti GE; Gillmann K; Rao HL; Mermoud A; Mansouri K
    J Clin Med; 2022 Aug; 11(16):. PubMed ID: 36013021
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Outcomes of XEN Gel Stent Implantation in the Inferonasal Quadrant after Failed Trabeculectomy.
    Düzgün E; Olgun A; Karapapak M; Alkan AA; Ustaoğlu M
    J Curr Glaucoma Pract; 2021; 15(2):64-69. PubMed ID: 34720495
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [High myopia in vitrectomized eyes : Contraindication for minimally invasive glaucoma surgery implant?].
    Huth A; Viestenz A
    Ophthalmologe; 2020 May; 117(5):461-466. PubMed ID: 31388758
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Case of Refractory Open-angle Glaucoma with Failed Baerveldt Glaucoma Implant and Trabeculectomy Treated with Ab Externo XEN Gel Stent Placement.
    Amoozadeh SA; Yang MC; Lin KY
    J Curr Glaucoma Pract; 2022; 16(3):192-194. PubMed ID: 36793261
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of surgical outcomes with and without Ologen collagen matrix augmentation during XEN gel stent implantation.
    Park J; Shin JW; Sung KR
    BMC Ophthalmol; 2022 Nov; 22(1):426. PubMed ID: 36348387
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Risk factors for ocular hypotony after XEN Gel Stent implantation.
    Galimi ME; Weller JM; Kruse FE; Laemmer R
    Graefes Arch Clin Exp Ophthalmol; 2023 Mar; 261(3):769-778. PubMed ID: 36201024
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Use of Fixation Suture to Treat Inferonasal Hypertrophic Bleb after Xen Gel Stent Implant: A Case Report.
    Pavičić-Astaloš J; Ankamah E; Nolan JM; Ng E; García-Feijoo J
    Case Rep Ophthalmol; 2022; 13(1):253-258. PubMed ID: 35611011
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.