168 related articles for article (PubMed ID: 38776107)
1. Design and Biocompatibility of a Novel, Flexible Artificial Cornea.
Li G; Aldave AJ; Amescua G; Colby KA; Cortina MS; de la Cruz J; Parel JA; Schmiedel TB; Akpek EK
Transl Vis Sci Technol; 2024 May; 13(5):19. PubMed ID: 38776107
[TBL] [Abstract][Full Text] [Related]
2. Twelve-Month Clinical and Histopathological Performance of a Novel Synthetic Cornea Device in Rabbit Model.
Akpek EK; Aldave AJ; Amescua G; Colby KA; Cortina MS; de la Cruz J; Parel JA; Li G
Transl Vis Sci Technol; 2023 Aug; 12(8):9. PubMed ID: 37561510
[TBL] [Abstract][Full Text] [Related]
3. Short-Term Clinical Outcomes of a Novel Corneal Prosthetic Device in a Rabbit Model.
Akpek EK; Van Court S; Glass S; Schmiedel T; Troutman M
Cornea; 2020 Jun; 39(6):706-712. PubMed ID: 31990845
[TBL] [Abstract][Full Text] [Related]
4. Design and evaluation of artificial cornea with core-skirt design using polyhydroxyethyl methacrylate and graphite.
Sinha M; Gupte T
Int Ophthalmol; 2018 Jun; 38(3):1225-1233. PubMed ID: 28602017
[TBL] [Abstract][Full Text] [Related]
5. The soft keratoprosthesis.
Caldwell DR
Trans Am Ophthalmol Soc; 1997; 95():751-802. PubMed ID: 9440192
[TBL] [Abstract][Full Text] [Related]
6. [Biocompatible study of modified titanium skirt for keratoprosthesis].
Li L; Zhou J; Wang XM; Wang XP; Cui FZ; Lu YJ; Huang YF
Zhonghua Yan Ke Za Zhi; 2010 Sep; 46(9):815-20. PubMed ID: 21092561
[TBL] [Abstract][Full Text] [Related]
7. A core-skirt designed artificial cornea with orthogonal microfiber grid scaffold.
Wang J; Chen Y; Bai Y; Quan D; Wang Z; Xiong L; Shao Z; Sun W; Mi S
Exp Eye Res; 2020 Jun; 195():108037. PubMed ID: 32343943
[TBL] [Abstract][Full Text] [Related]
8. A sintered graphene/titania material as a synthetic keratoprosthesis skirt for end-stage corneal disorders.
Li Z; Goh TW; Yam GH; Thompson BC; Hu H; Setiawan M; Sun W; Riau AK; Tan DT; Khor KA; Mehta JS
Acta Biomater; 2019 Aug; 94():585-596. PubMed ID: 31129362
[TBL] [Abstract][Full Text] [Related]
9. Preliminary evaluation of a hydrogel core-and-skirt keratoprosthesis in the rabbit cornea.
Crawford GJ; Chirila TV; Vijayasekaran S; Dalton PD; Constable IJ
J Refract Surg; 1996; 12(4):525-9. PubMed ID: 8771551
[TBL] [Abstract][Full Text] [Related]
10. [2nd generation bio-integrated keratoprosthesis. Implantation in animals].
Legeais JM; Drubaix I; Briat B; Renard G; Pouliquen Y
J Fr Ophtalmol; 1997; 20(1):42-8. PubMed ID: 9099283
[TBL] [Abstract][Full Text] [Related]
11. Engineering copolymeric artificial cornea with salt porogen.
Zellander A; Wardlow M; Djalilian A; Zhao C; Abiade J; Cho M
J Biomed Mater Res A; 2014 Jun; 102(6):1799-808. PubMed ID: 23784918
[TBL] [Abstract][Full Text] [Related]
12. A tectonic keratoprosthesis using expanded polytetrafluoroethylene as a supporting skirt in humans.
Ham DI; Lee JH
Korean J Ophthalmol; 1991 Dec; 5(2):83-7. PubMed ID: 1812290
[TBL] [Abstract][Full Text] [Related]
13. Design and fabrication of an artificial cornea based on a photolithographically patterned hydrogel construct.
Myung D; Koh W; Bakri A; Zhang F; Marshall A; Ko J; Noolandi J; Carrasco M; Cochran JR; Frank CW; Ta CN
Biomed Microdevices; 2007 Dec; 9(6):911-22. PubMed ID: 17237989
[TBL] [Abstract][Full Text] [Related]
14. Preparation and in vivo investigation of artificial cornea made of nano-hydroxyapatite/poly (vinyl alcohol) hydrogel composite.
Fenglan X; Yubao L; Xiaoming Y; Hongbing L; Li Z
J Mater Sci Mater Med; 2007 Apr; 18(4):635-40. PubMed ID: 17546425
[TBL] [Abstract][Full Text] [Related]
15. Keratoprostheses: advancing toward a true artificial cornea.
Hicks CR; Fitton JH; Chirila TV; Crawford GJ; Constable IJ
Surv Ophthalmol; 1997; 42(2):175-89. PubMed ID: 9381372
[TBL] [Abstract][Full Text] [Related]
16. [Artificial cornea].
Renard G
Bull Acad Natl Med; 1996 Mar; 180(3):659-65; discussion 665-8. PubMed ID: 8766246
[TBL] [Abstract][Full Text] [Related]
17. Development of a newly designed double-fixed Seoul-type keratoprosthesis.
Lee JH; Wee WR; Chung ES; Kim HY; Park SH; Kim YH
Arch Ophthalmol; 2000 Dec; 118(12):1673-8. PubMed ID: 11115262
[TBL] [Abstract][Full Text] [Related]
18. Biological response to a supraDescemetic synthetic cornea in rabbits.
Stoiber J; Fernandez V; Kaminski S; Lamar PD; Dubovy S; Alfonso E; Parel JM
Arch Ophthalmol; 2004 Dec; 122(12):1850-5. PubMed ID: 15596590
[TBL] [Abstract][Full Text] [Related]
19. T-style keratoprosthesis based on surface-modified poly (2-hydroxyethyl methacrylate) hydrogel for cornea repairs.
Xiang J; Sun J; Hong J; Wang W; Wei A; Le Q; Xu J
Mater Sci Eng C Mater Biol Appl; 2015 May; 50():274-85. PubMed ID: 25746271
[TBL] [Abstract][Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
[Next] [New Search]