  • 1. Functional and Radiological Outcomes of Miniature Plate Osteosynthesis in Metacarpal and Phalangeal Fractures of Hand: A Prospective Study.
    Singh R; Sharma PK; Verma V; Kamboj V; Shoeran A; Sharma J
    Cureus; 2024 Apr; 16(4):e58759. PubMed ID: 38779225
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of low-profile plate-screw and Kirschner-wire osteosynthesis outcomes in extra-articular unstable proximal phalangeal fractures.
    Köse A; Topal M; Engin MÇ; Şencan A; Dinçer R; Baran T
    Eur J Orthop Surg Traumatol; 2019 Apr; 29(3):597-604. PubMed ID: 30426217
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Soft tissue protective and minimally invasive osteosynthesis for metacarpal fractures II-V].
    Dumont C; Burchhardt H; Tezval M
    Oper Orthop Traumatol; 2012 Sep; 24(4-5):312-23. PubMed ID: 23053026
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analysis of 3 Different Operative Techniques for Extra-articular Fractures of the Phalanges and Metacarpals.
    Esteban-Feliu I; Gallardo-Calero I; Barrera-Ochoa S; Lluch-Bergadà A; Alabau-Rodriguez S; Mir-Bulló X
    Hand (N Y); 2021 Sep; 16(5):595-603. PubMed ID: 31517524
    [No Abstract]   [Full Text] [Related]  

  • 5. Kirschner Wires Versus Titanium Plates and Screws in Management of Unstable Phalangeal Fractures: A Randomized, Controlled Clinical Trial.
    El-Saeed M; Sallam A; Radwan M; Metwally A
    J Hand Surg Am; 2019 Dec; 44(12):1091.e1-1091.e9. PubMed ID: 30803743
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Management of extra-articular shaft fractures of the non-thumb metacarpals: plate-screw fixation versus K-wire fixation.
    Cheruvu VPR; Gaba S; John JR; Rawat S
    Int J Burns Trauma; 2021; 11(5):365-376. PubMed ID: 34858716
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of AO Titanium Locking Plate and Screw Fixation versus Anterograde Intramedullary Fixation for Isolated Unstable Metacarpal and Phalangeal Fractures.
    Zhang B; Hu P; Yu KL; Bai JB; Tian DH; Zhang GS; Shao XZ; Zhang YZ
    Orthop Surg; 2016 Aug; 8(3):316-22. PubMed ID: 27627714
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only.
    Başar H; Başar B; Başçı O; Topkar OM; Erol B; Tetik C
    Arch Orthop Trauma Surg; 2015 Apr; 135(4):499-504. PubMed ID: 25682110
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical outcomes of unstable metacarpal and phalangeal fractures treated with a locking plate system: a prospective study.
    Katayama T; Furuta K; Ono H; Omokawa S
    J Hand Surg Eur Vol; 2020 Jul; 45(6):582-587. PubMed ID: 31959035
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Plate Osteosynthesis of Distal Ulna Fractures with Associated Distal Radius Fractures Treated by Open Reduction and Internal Fixation. Short-Term Functional and Radiographic Results].
    Meluzinová P; Kopp L; Dráč P; Edelmann K; Obruba P
    Acta Chir Orthop Traumatol Cech; 2015; 82(5):369-76. PubMed ID: 26516956
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intramedullary screw fixation of metacarpal and phalangeal fractures - A systematic review of 837 patients.
    Hug U; Fiumedinisi F; Pallaver A; van de Wall BJM; Beeres FJP; Giesen T; Liechti R
    Hand Surg Rehabil; 2021 Oct; 40(5):622-630. PubMed ID: 33933635
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
    Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
    J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Percutaneous Retrograde Technique Using Intramedullary Headless Compression Screws for Metacarpal Fractures Under Wide-Awake Local Anaesthesia No Tourniquet.
    Ahmed N; Norris R; Faiaz A; Sharma A; Bindumadhavan S
    Cureus; 2022 Nov; 14(11):e31517. PubMed ID: 36540442
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical outcomes after mini-hook plate fixation for small avulsion fractures around the interphalangeal or metacarpophalangeal joints of the hand.
    Lee JI; Park KC; So HS; Lee DH
    J Orthop Surg Res; 2021 Mar; 16(1):186. PubMed ID: 33706801
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Extraarticular hand fractures in adults: a review of new developments.
    Freeland AE; Orbay JL
    Clin Orthop Relat Res; 2006 Apr; 445():133-45. PubMed ID: 16505726
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of surgical stabilization of metacarpal and phalangeal fractures of hand.
    Gupta R; Singh R; Siwach R; Sangwan S; Magu NK; Diwan R
    Indian J Orthop; 2007 Jul; 41(3):224-9. PubMed ID: 21139749
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparing treatment of proximal phalangeal fractures with intramedullary screws versus plating.
    Silins K; Turkmen T; Vögelin E; Haug LCP
    Arch Orthop Trauma Surg; 2023 Mar; 143(3):1699-1706. PubMed ID: 35994095
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcome of unstable fractures of metacarpal and phalangeal bones treated by bone tie.
    Kamath JB; Jayasheelan N; Savur A; Mathews R
    Indian J Orthop; 2016; 50(3):316-21. PubMed ID: 27293294
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous Cannulated Compression Screw Osteosynthesis in Phalanx Fractures: The Surgical Technique, the Indications, and the Results.
    Liodaki E; Kisch T; Wenzel E; Mailänder P; Stang F
    Eplasty; 2017; 17():e8. PubMed ID: 28293333
    [No Abstract]   [Full Text] [Related]  

  • 20. [Open reduction and low-profile plate and/or screw fixation in the treatment of phalangeal fractures].
    Nalbantoğlu U; Gereli A; Cilli F; Uçar BY; Türkmen M
    Acta Orthop Traumatol Turc; 2009; 43(4):317-23. PubMed ID: 19809228
    [TBL] [Abstract][Full Text] [Related]  