These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 38789219)

  • 21. Gestational diabetes alters the fetal heart rate variability during an oral glucose tolerance test: a fetal magnetocardiography study.
    Fehlert E; Willmann K; Fritsche L; Linder K; Mat-Husin H; Schleger F; Weiss M; Kiefer-Schmidt I; Brucker S; Häring HU; Preissl H; Fritsche A
    BJOG; 2017 Nov; 124(12):1891-1898. PubMed ID: 28029217
    [TBL] [Abstract][Full Text] [Related]  

  • 22. HTS magnetometers for fetal magnetocardiography.
    Li Z; Wakai RT; Paulson DN; Schwartz B
    Neurol Clin Neurophysiol; 2004 Nov; 2004():25. PubMed ID: 16012655
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Tracking Fetal Movement Through Source Localization From Multisensor Magnetocardiographic Recordings.
    Avci R; Wilson JD; Escalona-Vargas D; Eswaran H
    IEEE J Biomed Health Inform; 2018 May; 22(3):758-765. PubMed ID: 28391212
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Unshielded fetal magnetocardiography system using two-dimensional gradiometers.
    Seki Y; Kandori A; Kumagai Y; Ohnuma M; Ishiyama A; Ishii T; Nakamura Y; Horigome H; Chiba T
    Rev Sci Instrum; 2008 Mar; 79(3):036106. PubMed ID: 18377051
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Contribution of Fetal Magnetocardiography to Diagnosis, Risk Assessment, and Treatment of Fetal Arrhythmia.
    Wacker-Gussmann A; Strasburger JF; Wakai RT
    J Am Heart Assoc; 2022 Aug; 11(15):e025224. PubMed ID: 35904205
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Development and application of an automated extraction algorithm for fetal magnetocardiography - normal data and arrhythmia detection.
    Stingl K; Paulsen H; Weiss M; Preissl H; Abele H; Goelz R; Wacker-Gussmann A
    J Perinat Med; 2013 Nov; 41(6):725-34. PubMed ID: 23828424
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Fetal magnetocardiography: a promising way to diagnose fetal arrhytmia and to study fetal heart rate variability?].
    Hrtánková M; Biringer K; Siváková J; Šumichrastová P; Lukáč P; Danko J
    Ceska Gynekol; 2015 Jan; 80(1):58-63. PubMed ID: 25723081
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Characterizing atomic magnetic gradiometers for fetal magnetocardiography.
    Sulai IA; DeLand ZJ; Bulatowicz MD; Wahl CP; Wakai RT; Walker TG
    Rev Sci Instrum; 2019 Aug; 90(8):085003. PubMed ID: 31472627
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A computer-aided approach to detect the fetal behavioral states using multi-sensor Magnetocardiographic recordings.
    Vairavan S; Ulusar UD; Eswaran H; Preissl H; Wilson JD; Mckelvey SS; Lowery CL; Govindan RB
    Comput Biol Med; 2016 Feb; 69():44-51. PubMed ID: 26717240
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Coupling Analysis of Fetal and Maternal Heart Rates via Transfer Entropy Using Magnetocardiography.
    Avci R; Escalona-Vargas D; Siegel ER; Lowery CL; Eswaran H
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():1-4. PubMed ID: 30440290
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Assessment of atrioventricular conduction by echocardiography and magnetocardiography in normal and anti-Ro/SSA-antibody-positive pregnancies.
    Cuneo BF; Bitant S; Strasburger JF; Kaizer AM; Wakai RT
    Ultrasound Obstet Gynecol; 2019 Nov; 54(5):625-633. PubMed ID: 30784137
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A novel approach to track fetal movement using multi-sensor magnetocardiographic recordings.
    Govindan RB; Vairavan S; Ulusar UD; Wilson JD; McKelvey SS; Preissl H; Eswaran H
    Ann Biomed Eng; 2011 Mar; 39(3):964-72. PubMed ID: 21140290
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The natural history of fetal long QT syndrome.
    Cuneo BF; Strasburger JF; Wakai RT
    J Electrocardiol; 2016; 49(6):807-813. PubMed ID: 27539165
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Correlation of fetal heart rate dynamics to inflammatory markers and brain-derived neurotrophic factor during pregnancy.
    Mercado L; Rose S; Escalona-Vargas D; Siegel ER; Whittington JR; Preissl H; Helmich M; Eswaran H
    J Perinat Med; 2024 May; 52(4):399-405. PubMed ID: 38404246
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fetal magnetocardiogram waveform characteristics.
    Strand SA; Strasburger JF; Wakai RT
    Physiol Meas; 2019 Mar; 40(3):035002. PubMed ID: 30802886
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Fetal heart rate variation in magnetocardiography and cardiotocography--a direct comparison of the two methods].
    Schiermeier S; van Leeuwen P; Lange S; Geue D; Daumer M; Reinhard J; Grönemeyer D; Hatzmann W
    Z Geburtshilfe Neonatol; 2007 Oct; 211(5):179-84. PubMed ID: 17960515
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A 20-channel magnetoencephalography system based on optically pumped magnetometers.
    Borna A; Carter TR; Goldberg JD; Colombo AP; Jau YY; Berry C; McKay J; Stephen J; Weisend M; Schwindt PDD
    Phys Med Biol; 2017 Nov; 62(23):8909-8923. PubMed ID: 29035875
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Magnetocardiography for assessment of fetal heart actions].
    van Leeuwen P; Schüssler M; Bettermann H; Lange S; Hatzmann W
    Geburtshilfe Frauenheilkd; 1995 Nov; 55(11):642-6. PubMed ID: 8707042
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Entropy-based automated classification of independent components separated from fMCG.
    Comani S; Srinivasan V; Alleva G; Romani GL
    Phys Med Biol; 2007 Mar; 52(5):N87-97. PubMed ID: 17301449
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Indices and detectors for fetal MCG actography.
    Lutter WJ; Wakai RT
    IEEE Trans Biomed Eng; 2011 Jun; 58(6):1874-80. PubMed ID: 21427015
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.